ENTTEC-LOGO

ENTTEC 73539 DIN PIXIE

ENTTEC-73539-DIN-PIXIE-FIG-1

Tuotetiedot

Tekniset tiedot:

  • Mukautetun protokollan luontiopas
  • Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
  • Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2

Tuotteen käyttöohjeet

Esittely:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.

Asennusvaatimukset:

  • Datasheet of the desired pixel fixture
  • Computer to access the device settings page
  • For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
  • For DIN PIXIE: EMU Software for configuration

Guide to Custom Protocol Creation:

  1. Verify datasheet for compatible pixel protocol
  2. Navigate to the Device’s User Interface to enablethe  custom protocol feature
  3. Adjustthe  pixel fixture’s data voltage timing viathe  web interface based othe n datasheet

Step 1: Verify Datasheet for Compatible Protocol

  1. Check the data transmission method from the datasheet
  2. Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
  3. Choose a supported protocol with a similar data transmission method

YHTEENSOPIVA LAITEOHJELMISTO

Mukautetun protokollan luominen on mahdollista seuraavissa ENTTEC-pikseliohjaimissa:

SKU Tuote Laiteversio
73539 DIN PIXIE V2.0 tai uudempi
70067 PIXELATOR MINI V2.0 tai uudempi
70068 PIXELATOR MINI MK2 V1.0 tai uudempi
71521 OCTO MK2 V4.0 tai uudempi
71522 OCTO MK3 V1.0 tai uudempi

JOHDANTO

  • ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
  • Tämän ominaisuuden avulla käyttäjät voivat säätää äänenvoimakkuuttatage ajoitus tuettujen protokollien perusteella, jos tiedonsiirtomenetelmä vastaa jotakin tuetuista protokollistamme.
  • Tämä asiakirja sisältää asennusohjeet mukautetun pikseliprotokollan luomiseen ja ehtojen tarkistamiseen.

ASETUSVAATIMUKSET

Mukautetun protokollan luomiseen tarvitaan seuraavat:

  1. Tietolomake: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
  2. Laite: Use a computer to access the device settings page.
  3. For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
  4. For DIN PIXIE: Use the EMU Software for configuration.

OPAS MUKAUTETTUIN PROTOKOLLIN LUOMINEN

Tämän ominaisuuden avulla käyttäjät voivat säätää datavolyymiatage timing to meet specific protocol needs. To create a custom protocol:

  1. Tarkista yhteensopivan pikseliprotokollan tietolomake.
  2. Ota mukautettu protokollaominaisuus käyttöön siirtymällä laitteen käyttöliittymään.
  3. Säädä pikselilaitteiston datavoltage ajoitus kautta web käyttöliittymä valmistajan tuoteselosteen mukaisesti.

Vaihe 1: Tarkista yhteensopivan protokollan tietolomake

  1. Tarkista tietolomakkeesta haluamasi protokollan tiedonsiirtotapa.
    1. The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
      • Yleisin menetelmä siirtää dataa ilman lisäbittejä (esim. D1-D2-D3…Dn).
        Example: Tiedot on otettu WB2812B:n teknisistä tiedoista

        ENTTEC-73539-DIN-PIXIE-FIG-2

      • Jotkut protokollat, kuten TM1814, sisältävät lisädataa etupuolella (esim. C1-C2-D1-D2…Dn).
        Example: Tiedot poimittu TM1814:n datalehdestä

        ENTTEC-73539-DIN-PIXIE-FIG-3

  2. Nimeä laitteen tukema sovitusprotokolla (tai valitse yllä olevasta esimample) that shares the same data transmission method as your desired pixel protocol.
  3. Siirry vaiheeseen 2 lisämäärityksiä varten.

Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)

  1. Access to the OCTO/PIXELATOR MINI web käyttöliittymä
    1. Google Chromea suositellaan web browser to access the OCTO/PIXELATOR MINI’s web käyttöliittymä.
    2. Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webosoitteesta www.enttec.com ladataksesi sovelluksen.
    3. After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

      ENTTEC-73539-DIN-PIXIE-FIG-4
      Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
      See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.

  2. Navigate to the Settings page – Output Setting.
    Siirry lähtöön, johon haluttu pikselilaite on kytketty. Valitse avattavasta luettelosta pikseliprotokolla, jolla on sama lähetysmenetelmä, joka vahvistettiin vaiheessa 1.

    ENTTEC-73539-DIN-PIXIE-FIG-5

  3. Enable Custom protocol (Continue to Step 3)
    Ota 'Mukautettu' -valintaruutu käyttöön päästäksesi datavolyymiintage ajoituksen asetukset. Poista valinta, jos haluat poistaa mukautetun protokollan käytöstä.

    ENTTEC-73539-DIN-PIXIE-FIG-6

DIN PIXIE:lle

  1. Liitä DIN PIXIE tietokoneeseen USB Type-B:n avulla.
  2. Käynnistä EMU-ohjelmisto.
  3. Etsi laite ja napsauta löydetyn DIN PIXIE:n Conf.

    ENTTEC-73539-DIN-PIXIE-FIG-6

  4. Enable Custom Protocol (Continue to Step 3)
    Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.

    ENTTEC-73539-DIN-PIXIE-FIG-8

Vaihe 3: Aseta mukautettu voltage ajoitus

  1. Vastaa voltage ajoitus haluamasi protokollan tietolomakkeessa. Custom Protocol vaatii 4 syöttöä datavolyymin täydentämiseksitage ajoituksen säätö:
    Voitage Timing Definition
    Bitti 0 korkea aika (T0H) VoitagKoodin 0 vaatima korkea aika.
    Bitti 1 korkea aika (T1H) VoitagKoodin 1 vaatima korkea aika.
    Overall Bit Time: Kokonaistilavuustage time for a single bit.

    Lower limit = T0H+T0L

    Upper limit = T1H+T1L

    Nollaa aika Kokonaistilavuustagpieni aika, joka tarvitaan tiedonsiirron nollaamiseen kunkin dataerän välillä.

    ENTTEC-73539-DIN-PIXIE-FIG-9

  2. Datasheet – Data voltage ajoitustiedot esimample
    WB2818B:n teknisistä tiedoista
    • Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage ajoitusalue.
    • Täytä voltage aikaväli Output Settings -kohdan mukautetussa kentässä.

      ENTTEC-73539-DIN-PIXIE-FIG-10

TÄRKEÄÄ

  • ENTTEC recommends taking the median value of the range for the start.
  • Käyttäjän on TALLENNA asetukset, jotta muutettu arvo tulee voimaan.
  • Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
  • ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
  • Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.

PÄÄTELMÄ

  • Tämä opas osoitti mukautetun protokollan määrittämisen kelvollisille ENTTEC-laitteille ja tarjosi teknistä tietämystä haluamiesi pikselikiinnittimien tietosivun tarkistamiseen.
  • Seuraamalla näitä ohjeita käyttäjät voivat luoda mukautetun pikseliprotokollan, jota ei löydy avattavasta luettelosta odottamatta teknistä tukea tai uutta laiteohjelmiston julkaisua. Jos sinulla on kysyttävää tai sinulla on vaikeuksia löytää oikeaa tietoa, ota yhteyttä ystävälliseen tukitiimiimme paikallisissa toimistoissa.

FAQ

How do I access the device settings page on my computer?

You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web selain.

Can I create a custom protocol without the datasheet?

It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.

Asiakirjat / Resurssit

ENTTEC 73539 DIN PIXIE [pdfKäyttöohje
DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE

Viitteet

Jätä kommentti

Sähköpostiosoitettasi ei julkaista. Pakolliset kentät on merkitty *