COOLO Zigbee Occupancy Sensor User Manual

COOLO Zigbee Occupancy Sensor User Manual

COOLO-logoCOOLO Zigbee Occupancy Sensor

COOLO-Zigbee-Occupancy-Sensor-product

Yliview

This Zigbee 3.0 occupancy sensor detects human presence and motion using an onboard radar sensor. It includes a status indicator and a reset/pairing button for network configuration, and it requires connection to a Zigbee gateway to pair, communicate, and upload data.

Tekniset tiedot

Parametri Tekniset tiedot
Tuotteen nimi Zigbee Occupancy / Human Presence Sensor
Langaton protokolla Zigbee 3.0
Havaintokulma ≥80°
Havaintoetäisyys ≤5m
Työvoimatage 3.0V DC
Akun tyyppi CR2450
Valmiustilavirta ≤60uA
MMW Radar Frequency 10GHz / 24GHz (Optional Versions)

Ohjeet

Application remote control 
Master home safety through mobile APP and know home safety status at any time.COOLO-Zigbee-Occupancy-Sensor-fig (1)

Edistynyt liiketunnistin
P’R detects people or animals that are moving5m detectiordistance Whether day or night, can real-time monitoringCOOLO-Zigbee-Occupancy-Sensor-fig (2)

Go out, worry about burglars at home
Set a reminder of leave home, detect entering and leaving the mobile app, and receive the alarmCOOLO-Zigbee-Occupancy-Sensor-fig (3)

Don’t worry about getting p at night in the dark.
More security for light switches: night me PIR next to your bed, a-it of the senses ot the sensor to tun the I strip rx) more worrying meCOOLO-Zigbee-Occupancy-Sensor-fig (4)

Smart experience Beautiful life
With a motion sensor, the light automatically lights up in the hazy night when someone passes by, giving you enough securityCOOLO-Zigbee-Occupancy-Sensor-fig (6)

The connection to the gateway is very simple and only requires two stepsCOOLO-Zigbee-Occupancy-Sensor-fig (7)Jakaminen
Share control of this device with your family or friends through the App to enhance your relationship,COOLO-Zigbee-Occupancy-Sensor-fig (8)

Kuinka käyttää

  1. Power on: Align the opening tool with the battery compartment slot, rotate the battery cover anticlockwise to open and power on.
  2. Pair to Zigbee network: Press and hold the RESET button for 3 seconds, then release. Confirm the red LED flashes to enter network configuration mode.
  3. Install: Peel off the protective film from the adhesive pad on the base and firmly stick the sensor at the chosen location.
  4. Place for best coverage: Install at about 2.5m–3.5m above ground (or 1.5m–3.0m depending on environment).
Laatu assurance:
Under
normal use of users, the manufacturer provides a free 2- year product quality warranty (except for the panel) replacement, and provides lifelong maintenance quality assurance beyond the 2-year warranty period. The following conditions are not covered by the warranty:
  • Damage caused by external factors such as artificial damage or  water inflow;
  • Käyttäjä purkaa tai asentaa tuotteen itse (lukuun ottamatta paneelin purkamista ja kokoamista);
  • Tämän tuotteen teknisten parametrien lisäksi Ylivoimaisesta esteestä, kuten maanjäristyksestä tai tulipalosta, aiheutuvat tappiot;
  • Asennus, johdotus ja käyttö ei ole ohjeen mukainen;
  • Tuotteen parametrien ja skenaarioiden laajuuden ulkopuolella.

Pääsyasetukset:
Note: add an intelligent gateway before adding this device.

  • Install the battery on the device and make sure the mobile phone is connected to the network.
  • The first power-on will automatically enter the distribution network mode, or press the reset button (the reset button is on the back of  the product) with the pin for more than 10 seconds, and the device indicator will flash to enter the distribution network mode. After the distribution network is successful, the distribution network indicator will go out.
  • Open the app, click the gateway, and add a subdevice under the gateway. Make sure that the system automatically searches for the device after the indicator light flashes. After waiting for one minute, the system can automatically add the device.

Tuotteen rakennekaavio

COOLO-Zigbee-Occupancy-Sensor-fig (9)

Asennusmenetelmä:
Take the product out of the package, stick the double-sided adhesive tape on the back center of the product, tear off the protective paper of the adhesive tape, and paste it at any place where it needs to be installed.COOLO-Zigbee-Occupancy-Sensor-fig (10)

Mitta

COOLO-Zigbee-Occupancy-Sensor-fig (5)

Vianetsintä

  • Cannot pair/communicate: Ensure the sensor is connected to a Zigbee gateway; the manual notes it must be connected to successfully pair, communicate, and upload data.
  • False triggers (unwanted detections): If the default settings cause false triggers, decrease the motion detection sensitivity. Also ensure there are no obstacles directly in front of the radar induction area and avoid mounting near moving/vibrating objects (e.g., air conditioners, electric fans, waving curtains).
  • Static presence is not maintained: Increase the static detection sensitivity and set the Presence Keep Time to a longer duration (for configurations that support static presence).
  • Weak wireless performance: Avoid building obstacles between the sensor and the Zigbee gateway, as thick concrete walls can significantly reduce transmission range.

Asiakirjat / Resurssit

PDF thumbnailZigbee Occupancy Sensor
User Manual · Zigbee Occupancy Sensor, Occupancy Sensor, Sensor

Viitteet

Esitä kysymys

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Esitä kysymys

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.