Dasqua 3230-8115-A

Dasqua 3230-8115-A Digital Dual-Column Height Gauge User Manual

Model: 3230-8115-A | Brand: Dasqua

1. Johdanto

This manual provides comprehensive instructions for the safe and effective use, maintenance, and troubleshooting of your Dasqua 3230-8115-A Digital Dual-Column Height Gauge. Please read this manual thoroughly before operating the device to ensure optimal performance and longevity.

1.1 Tuote ohiview

The Dasqua 3230-8115-A is a precision digital height gauge designed for accurate measurement of height, depth, and step dimensions. It features a robust dual-column design for stability and a clear digital display for easy reading.

Dasqua 3230-8115-A Digital Dual-Column Height Gauge front view

Kuva 1.1: Etuosa view of the Dasqua 3230-8115-A Digital Dual-Column Height Gauge, showing the digital display and measuring jaw.

Dasqua 3230-8115-A Digital Dual-Column Height Gauge rear view

Kuva 1.2: Takaosa view of the height gauge, showing the handwheel for precise vertical adjustment.

Dasqua 3230-8115-A Digital Dual-Column Height Gauge detailed features

Kuva 1.3: Yksityiskohtainen view highlighting key features such as the fine adjustment mechanism, measuring scale, and stable base.

2. Turvallisuusohjeet

To ensure safe operation and prevent damage to the instrument or injury to the user, please observe the following safety guidelines:

3. Asennus

3.1 Pakkauksesta purkaminen ja alkutarkastus

Carefully remove the height gauge from its packaging. Inspect the instrument for any signs of damage that may have occurred during transit. Ensure all components listed in the packing list are present.

3.2 Akun asennus

The digital display requires a CR2032 lithium coin cell battery. To install or replace the battery:

  1. Locate the battery compartment cover on the side of the digital display unit.
  2. Liu'uta kansi auki nuolen osoittamaan suuntaan.
  3. Aseta uusi CR2032-paristo paikalleen positiivinen (+) puoli ylöspäin.
  4. Sulje paristolokeron kansi kunnolla.
Dasqua 3230-8115-A Digital Dual-Column Height Gauge battery compartment

Figure 3.1: Close-up of the battery compartment, showing the location for CR2032 battery insertion.

3.3 Mittaukseen valmistautuminen

Place the height gauge on a stable, flat, and clean surface. Ensure the measuring surface of the workpiece is also clean and free of burrs or debris.

4. Käyttöohjeet

4.1 Ohjauspaneeli ohiview

Familiarize yourself with the functions of the buttons on the digital display unit:

Dasqua 3230-8115-A Digital Dual-Column Height Gauge control panel with labeled buttons

Figure 4.1: Digital display control panel with numbered buttons and their corresponding functions.

4.2 Basic Measurement Procedure

  1. Paina ON/OFF button to power on the height gauge.
  2. Select the desired unit of measurement (mm or inch) by pressing the mm/in -painiketta.
  3. Clean the measuring surface of the height gauge base and the workpiece.
  4. Lower the measuring jaw until it makes contact with the reference surface (e.g., the surface the workpiece rests on).
  5. Paina ZERC/ABS button to set the display to zero at this reference point. This establishes your measurement origin.
  6. Carefully raise the measuring jaw using the handwheel until it makes contact with the feature you wish to measure on the workpiece.
  7. Lue mittaustulos suoraan digitaalinäytöltä.

4.3 Adjusting the Measuring Jaw

The measuring jaw can be adjusted for different measurement tasks. Loosen the locking screw, slide the jaw to the desired position, and then tighten the screw to secure it.

Dasqua 3230-8115-A Digital Dual-Column Height Gauge measuring jaw adjustment

Figure 4.2: Illustration of how to adjust and secure the measuring jaw for various applications.

5. Huolto

5.1 Puhdistus

Regular cleaning is essential for maintaining the accuracy and lifespan of your height gauge. Use a clean, soft, lint-free cloth to wipe down all surfaces. For stubborn dirt, a small amount of isopropyl alcohol can be used, but avoid contact with the digital display. Never use abrasive cleaners or solvents.

5.2 Varastointi

When not in use, store the height gauge in its original protective case in a dry, temperature-controlled environment. Avoid areas with high humidity, dust, or direct sunlight. Ensure the measuring jaw is not clamped tightly to prevent unnecessary stress on the mechanism.

5.3 Pariston vaihto

Replace the CR2032 battery when the display becomes dim or shows a low battery indicator. Refer to Section 3.2 for detailed battery installation instructions.

6. Vianmääritys

This section addresses common issues you might encounter with your height gauge. If the problem persists after attempting these solutions, please contact customer support.

OngelmaMahdollinen syyRatkaisu
Näyttö ei käynnisty.Tyhjä tai väärin asennettu akku.Replace the battery (CR2032) and ensure it is installed with correct polarity.
Epätarkkoja lukemia.Dirty measuring surfaces; instrument not zeroed correctly; environmental factors (temperature fluctuations).Clean all measuring surfaces. Re-zero the instrument. Ensure stable operating environment.
Näyttö välkkyy tai on epävakaa.Low battery; electromagnetic interference.Replace battery. Move the instrument away from strong electromagnetic fields.
Measuring jaw movement is stiff.Accumulated dirt or debris on the columns; locking screw too tight.Clean the columns thoroughly. Loosen the locking screw slightly.

7. Tekniset tiedot

Technical specifications for the Dasqua 3230-8115-A Digital Dual-Column Height Gauge:

OminaisuusYksityiskohta
Mallinumero3230-8115-A
Mittausalue0–600 mm
ValmistajaDasqua
Pakkauksen mitat89 x 30 x 18.5 cm
Tuotteen paino10.92 kg
Ensimmäinen vapaapäivä26. tammikuuta 2024

8. Takuu ja tuki

Dasqua products are manufactured to high quality standards and are typically backed by a manufacturer's warranty. Please refer to the warranty letter included with your product for specific terms and conditions regarding coverage and duration.

Dasqua 3230-8115-A Digital Dual-Column Height Gauge with packaging and warranty letter

Figure 8.1: The height gauge shown alongside its packaging and the included warranty letter.

For technical assistance, spare parts, or warranty claims, please contact your authorized Dasqua dealer or the customer support channel provided at the point of purchase. When contacting support, please have your model number (3230-8115-A) and purchase details ready.