ACiQ B0DHFF2DKL

ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System User Manual

Model: B0DHFF2DKL

1. Johdanto

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Turvallisuustiedot

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Sähköturvallisuus: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Kylmäaineen käsittely: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Asennus: Asennuksen saa suorittaa ainoastaan ​​valtuutettu LVI-alan ammattilainen.
  • Henkilökohtaiset suojavarusteet: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Tärkeimmät ominaisuudet

  • Invertteritekniikka: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • Korkea tehokkuus: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Laaja käyttöalue: Reliable performance from -13°F to 122°F.
  • Hiljainen toiminta: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Kestävät komponentit: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Ympäristöystävällinen kylmäaine: Utilizes R-454B refrigerant.
  • Joustava asennus: Supports horizontal and vertical air handler installation.
  • Älykkäät säätimet: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. Komponentit ohiview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Indoor Air Handler Unit
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • WiFi-termostaatti
  • Ylijännitesuoja
  • CPS Charging Adapter
  • Seinäholkki
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

Kuva 1: Yliview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Asennus ja asennus

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Asennusta edeltävät tarkastukset

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Varmista riittävästi tilaa sekä sisä- että ulkoyksiköille, jotta ilmanvaihto ja huoltomahdollisuudet ovat riittävät.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

Kuva 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Ulkoyksikön sijoittelu

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

Kuva 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Käyttöohjeet

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Peruskäyttötilat

  • Jäähdytystila: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Lämmitystila: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Tuulettimen tila: Kiertää ilmaa ilman lämmitystä tai jäähdytystä.
  • Automaattitila: Vaihtaa automaattisesti lämmityksen ja jäähdytyksen välillä asetetun lämpötilan ylläpitämiseksi.
ACiQ outdoor unit operating in extreme heat

Kuva 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

Kuva 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Smart Controls

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

Kuva 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Huolto

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Ilmansuodattimen vaihto: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Ulkoyksikön puhdistus: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Viemärijärjestelmä: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Ammattimainen tarkastus: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. Vianmääritys

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Ei virtaa: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Riittämätön lämmitys/jäähdytys: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Epätavalliset äänet: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • Vesivuotoja: Check condensate drain line for blockages.

9. Tekniset tiedot

Dimensions of ACiQ indoor and outdoor units

Kuva 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

Kuva 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

Kuva 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

OminaisuusYksityiskohta
Jäähdytyskapasiteetti31,000 BTU/tunti
Lämmityskapasiteetti30,000 BTU/hr (at 47°F)
SEER2-luokitus18.8
HSPF2-luokitus9.7
Kylmäaineen tyyppiR-454B
Sisäyksikön virtalähde115/208/230V, 60Hz, 1Ph
Ulkoyksikön virtalähde208/230 V, 60 Hz, 1 vaihe
Max putkiston pituus164 jalkaa (50 m)
Max Height Difference82 jalkaa (25 m)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
Sisäyksikön nettopaino128.97 lbs
Ulkoyksikön nettopaino164.02 lbs

10. Takuu ja tuki

ACiQ offers a comprehensive warranty for this heat pump system:

  • Osien takuu: 7 vuotta
  • Kompressorin takuu: 12 vuotta

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ websivusto.

Aiheeseen liittyvät asiakirjat - B0DHFF2DKL

Preview ACiQ 9K-24K Standard Heat -yksialuejärjestelmät: Asennus- ja käyttöopas
ACiQ 9K-24K -standardilämmitysjärjestelmien asennus- ja käyttöopas. Tämä opas sisältää yksityiskohtaiset tiedot ACiQ-ilmastointilaitteiden asennuksesta, käytöstä, turvallisuudesta ja huollosta, mukaan lukien mallikohtaiset tiedot ja tiedot R454B-kylmäaineesta.
Preview ACiQ-keskusinvertterijärjestelmien asennusopas
Kattava ACiQ-keskusinvertteriilmastointi- ja lämpöpumppujärjestelmien asennusopas, jossa kuvataan turvallisuusohjeet, kylmäaineputkisto, ulkoyksikön asennus, johdotus, tehotiedot, ilmanpoisto ja koekäyttömenettelyt.
Preview ACiQ-seinälle asennettavan ilmanvaihtokoneen ja Extreme Heat -yksialuekondensaattorin asennus- ja käyttöopas
Tämä käyttöohje sisältää yksityiskohtaiset asennus-, käyttö- ja turvallisuusohjeet ACiQ-seinälle asennettaville ilmanvaihtokoneille ja äärimmäisen kuumille yksivyöhykkeisille lauhduttimille, jotka kattavat mallit ACIQ-06W-HH-MD - ACIQ-24ZPL-HP230C.
Preview ACiQ-keskusinvertterijärjestelmien ulkoyksikön asennusopas
Kattava asennusopas ACiQ Central Inverter Systemsin ulkoyksiköille, joka kattaa turvaohjeet, kylmäaineputkiston, johdotuksen, yksikön asennuksen ja testausmenettelyt malleille, kuten ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB ja muille.
Preview ACiQ Next Gen -kanavalämpöpumppujärjestelmä: Termostaatin johdotuksen pikaopas
Tämä opas sisältää olennaisia ​​tietoja termostaattien kytkemisestä ja johdottamisesta ACiQ Next Gen -kanavalämpöpumppujärjestelmään. Siinä esitetään suositellut ja vaihtoehtoiset liitäntävaihtoehdot, mukaan lukien DIP-kytkinten asetukset ja riviliittimien kokoonpanot erityyppisille termostaateille.
Preview ACiQ Essentials Mini-Split Air Handler & Condenser Installation and Owner's Manual
Comprehensive installation and owner's manual for ACiQ Essentials Mini-Split Air Handler and Condenser systems, covering safety precautions, parts identification, remote control operation, installation procedures, test runs, maintenance, and troubleshooting for various models. The manual also includes critical information regarding the servicing of systems using flammable refrigerant R454B, emphasizing safety protocols and regulatory compliance. It is designed for professional installers and end-users to ensure safe and efficient operation of ACiQ mini-split heat pump systems.