ACiQ B0D522DYZ7

ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System User Manual

Model: B0D522DYZ7

1. Johdanto

This manual provides comprehensive instructions for the installation, operation, and maintenance of your ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System. Please read this manual thoroughly before installation and operation to ensure proper function and safety.

The ACiQ Inverter Heat Pump System is designed for high efficiency heating and cooling, adapting its output to meet changing weather conditions. It includes an inverter heat pump, a multi-positional cased evaporator coil, and a complete installation kit.

2. Turvallisuustiedot

Always adhere to local and national electrical and building codes. Installation and servicing should only be performed by qualified personnel.

  • Sähköturvallisuus: Disconnect all power before servicing. Ensure proper grounding.
  • Kylmäaineen käsittely: Only certified technicians should handle refrigerants.
  • Henkilökohtaiset suojavarusteet (PPE): Wear appropriate PPE, including gloves and eye protection, during installation and maintenance.
  • Paino: Components can be heavy. Use proper lifting techniques or seek assistance.

3. Järjestelmän komponentit

The ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Inverter Heat Pump: Converts AC power to DC, adjusting compressor speed and BTU output.
  • Höyrystimen käämi: Cased multi-positional coil with factory-integrated TXV kit.
  • Asennussarja: Includes Cielo Smart Thermostat, 50' insulated line set, 1/2" x 6' 10-gauge electrical whip, 60A non-fused disconnect switch, ICM Controls Surge Protector, CPS Charging Adapter, Wall Sleeve, and Wall Mount Bracket.
ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System components

Kuva 3.1: Päättynytview of the ACiQ Heat Pump System components, including the outdoor unit, indoor coil, thermostat, and various installation accessories.

ACiQ Complete Installation Kit

Kuva 3.2: Yksityiskohtainen view of the complete installation kit, showing the line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

4. Tekniset tiedot

4.1. Heat Pump Condenser Specifications

  • Summer Cooling Control: 36,000 BTU/H cooling precision
  • Winter Warmth Control: 36,000 to 35,000 BTU/H heating power
  • Energiatehokkuus: Up to 14.4 SEER (9.30 EER2) performance
  • Summer Proof Cooling: 5°F to 122°F outdoor temp operation
  • Winter Proof Heating: 5°F to 75°F outdoor temp operation
  • Lauhdutinkäämi: Gold fin for durability
  • Toiminta: Quietest operation at maximum workloads
Heat Pump Condenser Specifications

Figure 4.1: Visual representation of the heat pump condenser and its key specifications.

4.2. Evaporator Coil Specifications

  • Ilmavirta: 1058.82 CFM
  • Paine: 0.28 In. wg.
  • kosteudenpoisto: 4.64
  • Mitat (L x S x K): 21.52 x 20.98 x 23.58 tuumaa (547 x 533 x 599 mm)
  • Packing (W x D x H): 23.47 x 26.18 x 25.39 tuumaa (596 x 665 x 645 mm)
  • Netto/bruttopaino: 62.19 / 71.00 lbs (28.20 / 32.20 kg)

Note: The coil is specifically designed for use with gas furnaces or modular blowers and cannot be substituted for a one-piece air handler.

Evaporator Coil Specifications

Kuva 4.2: Yksityiskohtainen view of the evaporator coil with its dimensions and performance metrics.

4.3. Kokonaismitat

System Measurements

Figure 4.3: Overall dimensions of the outdoor heat pump unit and the evaporator coil.

5. Asennus ja asennus

Installation of this system requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC technician.

5.1. Asennusta edeltävä tarkistuslista

  • Varmista, että kaikki osat ovat paikalla ja ehjät.
  • Ensure proper electrical supply is available (voltage, ampkorotus).
  • Confirm adequate space for both indoor and outdoor units, allowing for proper airflow and service access.
  • Review local building codes and obtain necessary permits.

5.2. Ulkoyksikön sijoittelu

Place the outdoor unit on a level, stable surface, away from obstructions that could impede airflow. Ensure sufficient clearance around the unit for maintenance and proper operation.

Outdoor Unit Placement Example

Kuva 5.1: Esimample of an outdoor unit installed on a wall mount bracket, demonstrating proper clearance.

5.3. Evaporator Coil Installation

The evaporator coil is multi-positional. Install it in conjunction with a gas furnace or modular blower. Ensure proper drainage for condensate.

5.4. Line Set and Electrical Connections

  • Connect the insulated line set between the outdoor unit and the evaporator coil. Ensure proper flaring and torque.
  • Install the electrical whip and disconnect switch according to electrical codes.
  • Connect the ICM Controls Surge Protector for electrical protection.

5.5. Termostaatin asennus

Install the Cielo Smart Thermostat according to its dedicated instructions. This thermostat allows for app control and integration with smart home systems like Alexa, Google Home, Siri, SmartThings, and IFTTT.

Cielo Smart Thermostat Features

Figure 5.2: Diagram illustrating the features and connectivity options of the Cielo Smart Thermostat.

6. Käyttöohjeet

Once installed, the system can be operated via the Cielo Smart Thermostat or its associated mobile application.

6.1. Peruskäyttö

  • Virta päälle: Ensure the disconnect switch is in the ON position.
  • Tilan valinta: Use the thermostat to select operating modes: Cooling, Heating, Fan Only, or Auto.
  • Lämpötilan asetus: Säädä haluttu lämpötila termostaatin säätimillä.

6.2. Smart Thermostat Features

The Cielo Smart Thermostat offers advanced features for enhanced comfort and energy savings:

  • Ajoitus: Program daily or weekly schedules to optimize energy use.
  • Etäkäyttö: Control your system from anywhere using the mobile app.
  • Ääniohjaus: Integrate with Amazon Alexa, Google Assistant, or Apple Siri for hands-free control.
  • Älykkään kodin integrointi: Connect with SmartThings and IFTTT for advanced automation.

7. Huolto

Regular maintenance is crucial for optimal performance and longevity of your ACiQ system. It is recommended to have a qualified technician perform annual inspections.

7.1. Käyttäjän ylläpito

  • Ilmansuodattimen vaihto: Check and replace air filters monthly or as needed, especially during peak usage seasons.
  • Ulkoyksikön puhdistus: Keep the area around the outdoor unit clear of debris, leaves, and obstructions. Gently clean the exterior coils with a soft brush and water if necessary.
  • Kondenssiveden poisto: Periodically check the condensate drain line for clogs and ensure proper drainage.

7.2. Professional Maintenance

An annual professional tune-up typically includes:

  • Refrigerant level check and adjustment.
  • Coil cleaning (indoor and outdoor).
  • Sähköliitäntöjen tarkastus ja kiristys.
  • Blower motor and fan inspection.
  • Termostaatin kalibrointi.

8. Vianmääritys

This section provides solutions to common issues. For problems not listed here, or if solutions do not resolve the issue, contact a qualified HVAC technician.

OngelmaMahdollinen syyRatkaisu
Järjestelmä ei käynnistyEi virtaa, sulake lauennut, termostaatissa ongelmaCheck disconnect switch, reset breaker, ensure thermostat is powered and set correctly.
Riittämätön lämmitys/jäähdytysDirty air filter, blocked outdoor unit, low refrigerant, incorrect thermostat settingReplace air filter, clear obstructions from outdoor unit, check thermostat settings. Contact technician for refrigerant issues.
Epätavallisia ääniäIrtonaiset osat, tuulettimen tukos, kompressoriongelmaInspect for loose panels or debris. If noise persists, contact a technician.
Sisäyksiköstä vuotaa vettäClogged condensate drain line, frozen evaporator coilClear drain line. If coil is frozen, turn off system and allow to thaw, then check airflow. Contact technician if issue persists.

9. Takuutiedot

The ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System comes with a comprehensive warranty:

  • Osat: 7 vuoden takuu osille.
  • Kompressori: Kompressorilla 12 vuoden takuu.

Takuuehdot: The warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer at no additional charge. Please retain your proof of purchase and installation records.

10. Tuki ja yhteydenotto

For technical support, warranty claims, or service inquiries, please contact ACiQ customer service or visit our official websivusto.

ACiQ Official Websivusto: Visit the ACiQ Store on Amazon

Please have your model number (B0D522DYZ7) and purchase date ready when contacting support.