GIMA 28209

Gima Vega Uno Surgical Aspirator

Model: 28209 | Brand: GIMA

1. Johdanto

The Gima Vega Uno Surgical Aspirator is a compact and reliable medical device designed for the aspiration of liquids such as mucus, phlegm, and blood from nasal, oral, or tracheal passages in both adults and children. This device is suitable for minor surgical procedures and post-operative home care. It features instant suction intensity adjustment and a robust design for professional use.

Gima Vega Uno Aspirator recommended for nasal, oral, or tracheal fluid aspiration in adults or children.

Image 1.1: The Gima Vega Uno Aspirator is recommended for nasal, oral, or tracheal fluid aspiration in adults or children.

2. Turvallisuustiedot

Please read all instructions carefully before using the Gima Vega Uno Surgical Aspirator. Failure to follow safety guidelines may result in injury or damage to the device.

  • Varmista, että laite on käytön aikana vakaalla ja tasaisella alustalla.
  • Älä upota pääyksikköä veteen tai muuhun nesteeseen.
  • Pidä laite poissa lämmönlähteistä ja suorasta auringonpaisteesta.
  • Only use accessories and replacement parts approved by GIMA.
  • Regularly inspect all components for damage or wear before each use.
  • The electrical and thermal parts of the aspirator are insulated for safety. Do not attempt to open or repair the main unit. Refer servicing to qualified personnel.
  • Irrota aina virtajohto pistorasiasta ennen puhdistusta tai huoltoa.
  • This device is intended for medical use. Consult a healthcare professional for proper usage techniques and medical advice.
Insulated and safe electrical parts of the Gima Vega Uno Aspirator.

Image 2.1: The Gima Vega Uno features insulated and safe electrical parts.

3. Tuote ohiview

3.1 Komponentit

The Gima Vega Uno Surgical Aspirator typically includes the following components:

  • Aspirator main unit
  • Collection container (Makrolon, 1L or 2L)
  • Suction tubes (silicone, autoclavable)
  • Kertakäyttöinen suodatin
  • Conical connector for catheters
  • Käyttöohje
Diagram showing the components of the Gima Vega Uno Surgical Aspirator, including the main unit, collection container, tubes, and controls.

Image 3.1: Diagram of the Gima Vega Uno components and controls.

3.2 Tärkeimmät ominaisuudet

  • Silent and High-Flow Pumps: Designed for quiet operation and efficient fluid aspiration.
  • Maintenance-Free Pumps: Ensures long-lasting performance without frequent servicing.
  • Instant Suction Intensity Adjustment: Allows precise control over aspiration strength.
  • Unbreakable Makrolon Container: Durable collection container available in 1L or 2L capacity.
  • Autoclavable Components: The collection container and silicone tubes can be sterilized at 121°C.
  • Liquid Level Control Valve: Prevents overflow into the main unit.
  • Hydrophobic, Antibacterial, Anti-reflux Filter: Provides enhanced hygiene and protection.
  • Kompakti muotoilu: Helppo käsitellä ja säilyttää.
Illustration of the Gima Vega Uno's silent, high-flow, and maintenance-free pumps.

Image 3.2: The aspirator features silent, high-flow, and maintenance-free pumps.

Diagram illustrating the hydrophobic, antibacterial, and anti-reflux filter of the Gima Vega Uno.

Image 3.3: The filter is hydrophobic, antibacterial, and anti-reflux.

4. Asennusohjeet

  1. Pura pakkauksesta: Poista kaikki osat varovasti pakkauksesta. Tarkista, ettei niissä ole näkyviä vaurioita.
  2. Assemble Collection Container: Ensure the lid of the collection container is securely fastened.
  3. Connect Suction Tubes: Attach one end of the silicone suction tube to the 'PATIENT' port on the collection container lid. Connect the other end to the conical connector for the catheter.
  4. Connect Aspirator to Container: Connect the 'VACUUM' port on the collection container lid to the suction inlet on the main aspirator unit. Ensure all connections are tight to prevent air leaks.
  5. Lisää suodatin: Place the disposable filter between the collection container and the main unit, ensuring it is correctly oriented as per the markings.
  6. Virtaliitäntä: Plug the power cord into a suitable electrical outlet (230 Volt).
Gima Vega Uno Surgical Aspirator fully assembled with collection container and tubing.

Image 4.1: The Gima Vega Uno Aspirator ready for use.

5. Käyttöohjeet

  1. Virta päälle: Press the ON/OFF switch to turn on the aspirator. The indicator light will illuminate.
  2. Imutehokkuuden säätäminen: Use the regulation knob to adjust the desired suction intensity. Monitor the vacuum gauge (kPa/Bar) for the current suction level.
  3. Suorita imu: Carefully insert the catheter connected to the suction tube into the patient's nasal, oral, or tracheal passage as instructed by a healthcare professional.
  4. Monitor Collection Container: Observe the liquid level in the collection container. The integrated valve prevents overflow. Do not allow the container to overfill.
  5. Virta pois: Once aspiration is complete, press the ON/OFF switch to turn off the device.
  6. Katkaise yhteys: Irrota virtajohto pistorasiasta.

6. Huolto ja puhdistus

Proper maintenance and cleaning are crucial for the longevity and hygienic operation of your Gima Vega Uno Aspirator.

  • Päivittäinen siivous: After each use, empty and clean the collection container. The Makrolon container and silicone tubes are autoclavable at 121°C. Wash them with warm water and a mild detergent, then rinse thoroughly.
  • Sterilointi: For sterilization, place the cleaned container and tubes in an autoclave at 121°C according to standard sterilization protocols.
  • Suodattimen vaihto: The disposable filter should be replaced regularly, or immediately if it becomes wet or visibly soiled. Do not attempt to clean and reuse the filter.
  • Putkien tarkastus: Regularly inspect silicone tubes for any signs of wear, cracks, or blockages. If mold or persistent residue is observed inside the tubes, they should be thoroughly cleaned or replaced.
  • Ulkopuolen puhdistus: Pyyhi pääyksikön ulkopinta pehmeällä,amp liinalla. Älä käytä hankaavia puhdistusaineita äläkä upota laitetta veteen.
Image showing self-cleaning vessels, indicating ease of maintenance for the Gima Vega Uno.

Image 6.1: The aspirator features self-cleaning vessels for easy maintenance.

7. Vianmääritys

If you encounter issues with your Gima Vega Uno Aspirator, refer to the following common problems and solutions:

OngelmaMahdollinen syyRatkaisu
Ei imua tai heikko imu
  • Loose connections in tubing
  • Clogged catheter or tubing
  • Full collection container
  • Vaurioitunut suodatin
  • Improperly sealed container lid
  • Kuluneet tiivisteet
  • Check and tighten all tube connections.
  • Clear or replace the catheter/tubing.
  • Tyhjennä keräysastia.
  • Replace the disposable filter.
  • Ensure the container lid is securely closed.
  • Inspect and replace any worn seals (e.g., on the container lid). Applying a light silicone paste to seals can improve performance.
Laite ei käynnisty
  • Ei virtalähdettä
  • Viallinen virtajohto
  • Tarkista, että virtajohto on kytketty kunnolla toimivaan pistorasiaan.
  • Testaa pistorasia toisella laitteella.
  • If the power cord is damaged, contact customer support for a replacement.
Epätavallinen ääni käytön aikana
  • Sisäinen komponenttiongelma
  • Löysät osat
  • Sammuta laite välittömästi.
  • Contact customer support for assistance. Do not attempt to open the unit.

8. Tekniset tiedot

ErittelyYksityiskohta
ValmistajaCA-MI SRL
Mallinumero28209
Tuotteen paino2.2 kiloa
Tuotteen mitat25 x 19 x 16.5 cm
Volume of Item1 Litre (container)
Voitage230 volttia
ErikoisominaisuudetKompakti
Mukana olevat komponentitAspirator, manual
Paristot vaaditaanEi

9. Takuu ja tuki

For warranty information, technical support, or to purchase replacement parts, please contact GIMA customer service or your authorized distributor. Keep your purchase receipt as proof of purchase.

Aiheeseen liittyvät asiakirjat - 28209

Preview GIMA SUPERVEGA -AKKUIMURYKSIKÖN käyttöohje ja tekninen opas
Tämä asiakirja sisältää kattavat käyttöohjeet, turvallisuusmääräykset, tekniset tiedot ja huoltotoimenpiteet GIMA SUPERVEGA -akkuimurilaitteelle (malli 28193), joka on ammattimainen lääkinnällinen imulaite.
Preview GIMA S/S Bierer Aspiration Tube - User Manual & Specifications (Models 28262, 28264)
Official user manual and technical specifications for the GIMA S/S Bierer Aspiration Tube (Models 28262 and 28264). Details intended use, features, procedure, cleaning, sterilization, operating conditions, and manufacturer information.
Preview GIMA Silicone Tubes - Medical Grade Tubing Specifications
Detailed technical specifications, usage instructions, and warranty information for GIMA's high-quality silicone medical tubes, designed for external medical use and substance transit.
Preview GIMA TOBI MANUALE -imuri - Käyttöopas ja tekniset tiedot
Kattava käyttöohje ja tekniset tiedot GIMA TOBI MANUALE -imurille. Opi sen ominaisuuksista, turvallisuusohjeista, puhdistuksesta, huollosta ja vianetsinnästä.
Preview GIMA aikuisille tarkoitettu kielilappu - lääkinnällinen laite suun tutkimiseen
GIMA Adult-Type Tongue Depressorin viralliset tuotetiedot, suun tutkimuksiin suunniteltu lääkinnällinen laite. Tiedot sisältävät käyttöaiheet, vasta-aiheet, varoitukset, säilytyksen, suorituskykyominaisuudet, rakenteellisen koostumuksen, käyttötavan, turvallisuusraportoinnin, takuun ja valmistajan tiedot.
Preview GIMA-pulssioksimetrin käyttöohje - tekniset tiedot ja käyttöopas
Kattava GIMA-pulssioksimetrin antureiden käyttöopas, joka kattaa tuotteen tekniset tiedot, käyttötarkoituksen, kliiniset hyödyt, huollon, puhdistuksen, desinfioinnin, ympäristövaatimukset ja sähkömagneettisen yhteensopivuuden (EMC) tiedot. Sisältää mallinumerot ESA0015, ESC0029 ja muita tietoja.