1. Johdanto
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the GEWISS P-COMFORT GWD6916 Wired Load Management Relay. Please read this manual thoroughly before attempting any installation or operation.
The GEWISS P-COMFORT GWD6916 is designed to manage electrical loads in an installation, optimizing energy consumption and preventing overloads. It is a wired version, ensuring reliable communication and control.
Turvallisuustiedot
- Ammattimainen asennus: Installation and maintenance must be performed by qualified personnel in accordance with local electrical codes and regulations.
- Katkaise virta: Always disconnect the main power supply before performing any installation, wiring, or maintenance procedures.
- Voitage: Varmista syöttötilavuustage matches the device's specifications (250 Volt).
- Ympäristöolosuhteet: Älä altista laitetta kosteudelle, äärimmäisille lämpötiloille tai syövyttäville ympäristöille.
2. Pakkauksen sisältö
Varmista avatessasi pakkauksen, että kaikki osat ovat mukana ja vahingoittumattomia:
- 1 x GEWISS P-COMFORT GWD6916 Wired Load Management Relay
- 1 x Käyttöohje (tämä asiakirja)

Kuva 1: Edessä view of the GEWISS P-COMFORT GWD6916 Wired Load Management Relay. The image shows the compact housing, terminal blocks for wiring, and indicator lights.
3. Asennus
Follow these steps for proper installation of the GEWISS P-COMFORT GWD6916 relay.
3.1 Asennus
- Valitse sijainti: Choose a suitable location within an electrical enclosure, ensuring adequate ventilation and protection from environmental factors.
- Asennus: The relay is designed for DIN rail mounting. Securely attach the device to the DIN rail until it clicks into place.
3.2 Johdotus
Varoitus: Ensure power is disconnected before proceeding with wiring.
- Virtalähde: Connect the main power supply (250 Volt) to the designated input terminals as indicated on the device's wiring diagram.
- Lataa liitännät: Connect the loads to be managed by the relay to the output terminals. Ensure correct polarity and current ratings are observed.
- Ohjaustulo: Connect the control signal (e.g., from a master load management unit or energy meter) to the dedicated control input terminals. This signal dictates when loads should be shed or reconnected.
- Maadoitus: Ensure proper grounding of the device and associated electrical components.
Refer to the detailed wiring diagram printed on the device or included in the packaging for specific terminal assignments.
4. Käyttö
Once installed and wired correctly, the GEWISS P-COMFORT GWD6916 relay operates automatically based on the control input it receives.
4.1 Power-Up and Initial Check
- Palauta virta: After completing all wiring and safety checks, restore power to the installation.
- Merkkivalot: Observe the indicator lights on the relay. A power indicator should illuminate, confirming the device is receiving power. Other indicators will show the status of the loads being managed.
4.2 Load Management Function
The relay functions by switching connected loads ON or OFF in response to a control signal. Typically, this signal originates from a central load management system that monitors total energy consumption. When the total consumption exceeds a predefined threshold, the control system signals the relay to disconnect non-essential loads (load shedding) to prevent an overload. When consumption drops, the loads are reconnected.
4.3 Tilailmaisimet
The relay features LED indicators to provide visual feedback on its operational status:
- Virran merkkivalo: Indicates that the device is powered ON.
- Tila-LED: May indicate operational status, errors, or communication status with the control unit. Refer to the device's specific documentation for LED behavior.
- Load Status LEDs: Individual LEDs may indicate the ON/OFF status of each controlled load.
5. Huolto
The GEWISS P-COMFORT GWD6916 relay is designed for reliable, long-term operation with minimal maintenance.
- Puhdistus: Puhdista laitteen ulkopinta säännöllisesti pehmeällä, kuivalla liinalla. Älä käytä hankaavia puhdistusaineita tai liuottimia.
- Tarkastus: Annually, or as required by local regulations, have a qualified electrician inspect the wiring connections for tightness and signs of wear or damage.
- Ei käyttäjän huollettavia osia: The device contains no user-serviceable parts. Do not attempt to open or repair the unit.
6. Vianmääritys
If you encounter issues with your GEWISS P-COMFORT GWD6916 relay, refer to the following common problems and solutions:
| Ongelma | Mahdollinen syy | Ratkaisu |
|---|---|---|
| Device has no power (Power LED off) | No power supply, loose wiring, tripped circuit breaker. | Check main power supply. Verify wiring connections. Reset circuit breaker. |
| Loads are not switching ON/OFF as expected | Incorrect control signal, faulty wiring to loads, internal fault. | Verify the control signal from the master unit. Check wiring to loads. If problem persists, consult a qualified electrician. |
| Epätavallisia ääniä tai hajuja | Internal component failure, overheating. | Immediately disconnect power. Do not attempt to operate. Contact a qualified electrician or Gewiss support. |
For issues not listed above or if troubleshooting steps do not resolve the problem, contact a qualified electrician or Gewiss technical support.
7. Tekniset tiedot
| Ominaisuus | Yksityiskohta |
|---|---|
| Malli | GWD6916 |
| Merkki | Gewiss |
| Tyyppi | Wired Load Management Relay |
| Voitage | 250 volttia |
| Mitat (P x L x K) | 10 x 8 x 4 cm |
| Paino | 60 g |
| Asennus | DIN-kisko |
8. Takuu ja tuki
The GEWISS P-COMFORT GWD6916 is covered by a standard manufacturer's warranty. Please refer to the warranty card included with your purchase or visit the official Gewiss websivustolta tarkemmat takuuehdot.
For technical assistance, product inquiries, or warranty claims, please contact Gewiss customer support through their official channels. Ensure you have your product model number (GWD6916) and purchase details available when contacting support.
Gewissin virkamies Websivusto: www.gewiss.com