Johdanto
This manual provides detailed instructions for the installation, operation, and maintenance of your TOPGREENER Kalide Dual Load Dimmer Light Switch, Model TGDDS-GY. Please read all instructions carefully before beginning installation to ensure proper function and safety.

Kuva: Edessä view of the TOPGREENER Kalide Dual Load Dimmer Light Switch, Model TGDDS-GY.
Turvallisuustiedot
VAROITUS: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. Installation should be performed by a qualified electrician or a person with a thorough understanding of electrical wiring.
- Use only with dimmable LED, CFL, incandescent, or halogen bulbs.
- Do not use with non-dimmable bulbs or smart lighting fixtures.
- For single-pole applications only.
- Ensure wiring connections are secure and insulated.
- Käyttö voltage: 120VAC, 60Hz.
Tuotteen ominaisuudet
- Dual Load Dimming: Controls two separate light loads from a single wall switch location.
- Full-Range Dimming: Two independent sliders allow for precise light level adjustment for each load.
- Yhteensopivuus: Supports major-brand dimmable LED, CFL, incandescent, and halogen bulbs.
- Neutral Wire Not Required: Simplifies installation in older homes or locations without a neutral wire.
- Kestävä rakenne: Made of Polycarbonate Thermoplastic material for impact and heat resistance.
- Tilaa säästävä muotoilu: Occupies only one gang space for efficient use of electrical box capacity.

Image: Diagram highlighting the light level settings and noticeable stops on the dual sliders of the dimmer switch.

Image: Visual representation of bulb compatibility, indicating support for dimmable LED bulbs and non-compatibility with RGB, three-color, and Wi-Fi smart bulbs.
Asennusopas
Esiasennus
- Sammuta virta: Locate the circuit breaker or fuse box that controls the light fixture you are working on. Turn off the power completely. Verify power is off using a voltage testaaja.
- Vanhan kytkimen poistaminen: Carefully remove the existing wall plate and switch from the electrical box. Disconnect the wires from the old switch.
Johdotusohjeet
The Kalide TGDDS-GY dimmer is designed for single-pole applications and does not require a neutral wire. It has screw terminals for secure connections.
- Linjajohto: Connect the incoming hot wire (usually black) from the circuit breaker to one of the dimmer's screw terminals.
- Load Wires (2): Connect the two wires going to your light fixtures (loads) to the remaining two screw terminals on the dimmer. Each slider controls one load.
- Maadoitusjohto: Connect the bare copper or green insulated ground wire from the electrical box to the dimmer's green ground screw.
Ensure all wire connections are tight and properly insulated with electrical tape or wire nuts.

Image: Illustrates that the dimmer switch does not require a neutral wire, making it compatible with standard electrical wiring in various homes.
Asennus
- Carefully fold the wires into the electrical box.
- Secure the dimmer switch to the electrical box using the provided screws.
- Attach the wall plate (sold separately) over the dimmer switch.
- Palauta virta: Kytke virta takaisin katkaisijasta.
Käyttöohjeet
The Kalide Dual Load Dimmer features two independent sliders for controlling two separate lighting loads.
- Turning Lights ON/OFF: To turn a light load ON, slide the corresponding slider upwards. To turn it OFF, slide the slider all the way down until it clicks.
- Kirkkauden säätö: Move the slider up to increase brightness and down to decrease brightness. Each slider controls its respective light load independently.
Video: Demonstrates the operation of the TOPGREENER Kalide Dual Load Dimmer Light Switch, showing how to adjust brightness for two separate light loads using the independent sliders.

Kuva: Lähikuva view of the dimmer switch, illustrating the two distinct sliders for controlling individual light loads.
Huolto
To maintain the appearance and functionality of your dimmer switch:
- Puhdista pehmeällä, damp kangas. Älä käytä hankaavia puhdistusaineita tai liuottimia.
- Ensure the switch is free from dust and debris to prevent interference with slider movement.
Vianetsintä
| Ongelma | Mahdollinen syy | Ratkaisu |
|---|---|---|
| Valot eivät syty tai sammu. | No power to the switch; loose wiring; faulty bulb. | Tarkista sulake; tarkista johdotuksen liitännät; vaihda lamppu. |
| Valot eivät himmene tai välky. | Non-dimmable bulbs; incompatible bulb type; minimum load not met. | Ensure bulbs are dimmable; check bulb compatibility; consult bulb manufacturer for minimum load requirements. |
| Dimmer switch is hot to the touch. | Overload; improper ventilation. | Vähennä kokonaistehoatage of connected bulbs; ensure proper air circulation around the switch. |
| Switch becomes unresponsive or goes to auto-dim. | Internal malfunction or temporary electrical anomaly. | Try cycling the sliders fully up and down to reset. If issue persists, contact support. |
Tekniset tiedot
| Attribuutti | Yksityiskohta |
|---|---|
| Malli | TGDDS-GY |
| Käyttö Voltage | 120VAC, 60Hz |
| Load (LED/CFL) | 200W Maks |
| Load (Incandescent/Halogen) | 300W Maks |
| Piirin tyyppi | Yksinapainen |
| Johdotusvaatimus | Neutral Wire Not Required |
| Wire Gauge | #14-#12 AWG (copper only) |
| Materiaali | Polykarbonaatti termoplastia |
| Sertifikaatit | UL listattu |
| Mitat | 4.65 x 2.32 x 2.32 tuumaa |
Takuu ja tuki
This TOPGREENER Kalide Dual Load Dimmer Light Switch (Model TGDDS-GY) comes with a 1 vuoden takuu ostopäivästä alkaen.
For technical assistance, troubleshooting not covered in this manual, or warranty claims, please contact TOPGREENER customer support. Refer to the product packaging or the official TOPGREENER websivustolta ajantasaiset yhteystiedot.