Elitech PG-30Pro

Elitech PG-30Pro digitaalisen painemittarin käyttöohje

Model: PG-30Pro

Johdanto

The Elitech PG-30Pro Digital Pressure Gauge is designed for precise real-time pressure measurement in various systems, including pipeline and refrigeration applications. It features a clear backlight display, automatic shutdown, low battery indication, and an over-pressure warning light for enhanced safety and usability. Its robust design and long battery life make it a reliable tool for professionals.

This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your PG-30Pro Digital Pressure Gauge. Please read it thoroughly before use.

Tuotteen ominaisuudet

  • Taustavalo näyttö: Ensures clear visibility of readings in various lighting conditions.
  • Max/Min Value Display and Reset: Records maximum and minimum pressure values, with an option to reset for new data collection.
  • Nollaustoiminto: Allows for calibration to correct any deviation at the zero point.
  • Laaja kylmäaineyhteensopivuus: Supports over 90 common refrigerants, making it versatile for various AC and refrigeration systems.
  • Auto Shut-Off Setting: Säätää akun käyttöikää kytkeytymällä automaattisesti pois päältä, kun se on ollut käyttämättömänä.
  • Adjustable Temperature and Pressure Units: Users can select preferred units for both temperature and pressure measurements.
  • Alhaisen akun ilmaisin: Displays "LOB" when battery power is low.
  • Over-Pressure Warning: Alerts the user to potentially damaging pressure levels.
Elitech PG-30Pro Digital Pressure Gauge with key features highlighted

Image: Elitech PG-30Pro Digital Pressure Gauge showcasing its main features including backlight, Max/Min display, zeroing function, refrigerant compatibility, auto shut-off, and adjustable units.

Asennus

1. Akun asennus

  1. Paikanna laitteen takaosassa oleva paristolokeron kansi.
  2. Open the cover and insert three (3) AAA batteries, ensuring correct polarity (+/-).
  3. Sulje paristolokeron kansi kunnolla.

2. Connecting the Gauge

  • The PG-30Pro is equipped with a standard 1/8-inch NPT fitting.
  • Ensure the system you are connecting to is compatible with this fitting size.
  • Carefully thread the gauge onto the system's pressure port. Do not overtighten.
  • Verify a secure, leak-free connection before proceeding with measurements.
Elitech PG-30Pro Digital Pressure Gauge showing 1/8-inch fitting dimensions

Image: The Elitech PG-30Pro Digital Pressure Gauge illustrating its 1/8-inch NPT fitting and overall dimensions for connection reference.

Käyttöohjeet

1. Virta päälle/pois

Paina POWER button (usually marked with a circle and vertical line) to turn the device on. Press and hold the POWER sammuttamalla se.

2. Yksikön valinta

Paina SARJA button to cycle through available pressure units (MPa, kPa, bar, psi, kg/cm²) and temperature units (°C, °F). Select the desired units for your measurement.

Elitech PG-30Pro Digital Pressure Gauge displaying adjustable temperature and pressure units

Image: The Elitech PG-30Pro Digital Pressure Gauge showing its display with adjustable temperature and pressure units, such as psi and °C/°F.

Elitech PG-30Pro Digital Pressure Gauge display with blue backlight

Image: A close-up of the Elitech PG-30Pro Digital Pressure Gauge's LCD display with its blue backlight activated, showing pressure and temperature readings.

3. Zeroing Function

Before taking a measurement, especially in a new environment or after a long period of storage, it is recommended to zero the gauge. With no pressure applied, press the NOLLA button to reset the reading to zero. This corrects any potential deviation and ensures accurate measurements.

4. Max/Min Value Recording

The gauge automatically records the maximum and minimum pressure values during operation. To view these values, press the SARJA button repeatedly until "MAX" or "MIN" appears on the display. To clear these recorded values and start a new recording cycle, press and hold the NOLLA -painiketta viewing the MAX/MIN display.

Elitech PG-30Pro Digital Pressure Gauge showing Max/Min value display and reset buttons

Image: The Elitech PG-30Pro Digital Pressure Gauge highlighting the Power and Zero buttons, used for Max/Min value display and reset.

5. Refrigerant Selection (PT Table)

The PG-30Pro has a built-in pressure-temperature (PT) comparison table for over 90 common refrigerants. This allows for convenient reference during HVAC and refrigeration system work. Consult the device's specific menu or accompanying documentation for how to access and utilize this feature.

Elitech PG-30Pro Digital Pressure Gauge showing compatibility with various refrigerants

Image: The Elitech PG-30Pro Digital Pressure Gauge demonstrating its compatibility with a wide range of refrigerants, including R12, R22, R134a, R401A, and others.

Huolto

  • Puhdistus: Pyyhi laite pehmeällä, damp kangas. Älä käytä hankaavia puhdistusaineita tai liuottimia.
  • Varastointi: Store the gauge in a dry, cool place away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
  • Akun vaihto: Replace batteries when the "LOB" indicator appears on the display. Ensure to use three (3) new AAA batteries.
  • Tarkastus: Regularly inspect the pressure port and fitting for any signs of damage or wear. Replace if necessary to ensure accurate and safe operation.

Vianetsintä

OngelmaMahdollinen syyRatkaisu
Laite ei käynnisty.Tyhjät tai väärin asennetut paristot.Tarkista paristojen napaisuus. Vaihda tilalle uudet AAA-paristot.
Epätarkkoja lukemia.Gauge not zeroed; faulty connection; sensor issue.Perform zeroing function. Check for leaks at the connection. If problem persists, contact support.
"LOB" displayed.Alhainen akun teho.Vaihda paristot välittömästi.
Näyttö on himmeä tai välkkyvä.Low battery power; environmental conditions.Replace batteries. Ensure operating within specified temperature range.

Tekniset tiedot

ParametriArvo
MalliPG-30Pro
Paineen mittausalue-0.100 to 5.515 MPa (0 to 800 psi)
Käyttölämpötila10 °C - 60 °C (50 °F - 140 °F)
Käyttökosteus35 % - 85 % RH
Resoluutio0.001 MPa, 0.1 psi
Tarkkuus±0.5% FS (Full Scale)
Lämpötilayksiköt° C / ° F
Akun kestoJopa 1 vuosi
Virtalähde3 x AAA paristot
Sampling-kausi1 sekuntia
Näyttö1.9 x 1 inch LCD with Blue Backlight
MittayksikötMPa, kPa, bar, psi, kg/cm², cmHg
Asennus1/8 tuuman NPT
Tuotteen mitat (P x L x K)45 x 45 x 197 mm (1.77 x 1.77 x 7.76 tuumaa)
Tuotteen paino248 g (8.78 unssia)
MateriaaliMuovi
Kylmäaineen yhteensopivuusOver 90 types
Various applications of Elitech PG-30Pro Digital Pressure Gauge

Kuva: esimamples of the Elitech PG-30Pro Digital Pressure Gauge in use across various applications, including automotive AC maintenance, residential AC installation, cold storage temperature control, commercial refrigeration inspection, heat pump system pressure testing, and refrigerant recovery and charging.

Takuu ja tuki

For warranty information, technical support, or service inquiries, please contact Elitech customer service. Refer to the product packaging or Elitech's official websivustolta ajantasaisimmat yhteystiedot.

Websivusto: www.elitech.com

Please have your product model (PG-30Pro) and purchase date available when contacting support.