1. Johdanto
This user manual provides detailed instructions for the installation, operation, and maintenance of the AKO D14012 12V Panel-Mounted Digital Temperature Display. This device is designed for precise temperature indication in either Celsius (°C) or Fahrenheit (°F), featuring selectable NTC/PTC probe programs and a simple single-button interface for settings. Please read this manual thoroughly before using the device to ensure correct operation and to prevent damage.
2. Turvallisuustiedot
- Sähköturvallisuus: Ensure the power supply is disconnected before installation or maintenance. The device operates on 12V DC. Incorrect voltagVäärä napaisuus voi vahingoittaa laitetta.
- Asennus: Installation should only be performed by qualified personnel. Follow all local electrical codes and regulations.
- Ympäristö: Älä altista laitetta liialliselle kosteudelle, pölylle tai äärimmäisille lämpötiloille sen määritellyn käyttöalueen ulkopuolella.
- Anturin käsittely: Handle the temperature probe carefully. Do not bend or crimp the cable excessively.
- Puhdistus: Käytä puhdistukseen pehmeää, kuivaa liinaa. Älä käytä hankaavia puhdistusaineita tai liuottimia.
3. Pakkauksen sisältö
Varmista avatessasi pakkauksen, että kaikki osat ovat mukana ja vahingoittumattomia:
- AKO D14012 Digital Temperature Display Unit
- Temperature Probe (NTC/PTC compatible)
- Kiinnitysklipsit (2 kpl)

Kuva 3.1: Contents of the AKO D14012 package, showing the main display unit, the coiled temperature probe, and two mounting clips.
4. Tuote ohiview
The AKO D14012 is a compact digital temperature display designed for integration into control panels. It features a clear digital display for temperature readings and a single "SET" button for configuration. The unit is powered by 12V DC and connects to an external temperature probe.
4.1. Tärkeimmät komponentit
- Digitaalinen näyttö: Näyttää nykyisen lämpötilan.
- SET -painike: Used to access and adjust device settings and parameters.
- Probe Input: Connection point for the NTC/PTC temperature sensor.
- Tehon syöttö: Terminals for 12V DC power supply.
5. Asennus
5.1. Paneeliasennus
The AKO D14012 is designed for panel mounting. Create an opening in your control panel with the following dimensions:
- Leveys: 70.5 mm
- Korkeus: 28.5 mm
Insert the display unit into the opening and secure it using the provided mounting clips on the sides of the unit.

Kuva 5.1: Panel cutout dimensions and rear wiring diagram for the AKO D14012 unit.
5.2. Johdotusliitännät
Refer to Figure 5.1 for the wiring diagram. Ensure power is disconnected before making any connections.
- Anturin liitäntä: Connect the temperature probe to the designated terminals on the left side of the unit (labeled "Sonda" in the diagram).
- Virtalähde: Connect the 12V DC power supply to the terminals on the right side. Ensure correct polarity: connect 12V to the positive terminal and 0V to the negative terminal (labeled "12V=" and "0V" respectively in the diagram). The device is designed for 12V DC operation.
After all connections are made, you can apply power to the unit.
6. Käyttöohjeet
6.1. Kytke virta päälle
Once correctly wired and powered, the display will illuminate and show the current temperature measured by the probe.
6.2. Viewlämpötila
The primary function of the device is to continuously display the temperature. The reading will update automatically as the temperature changes.
6.3. Accessing Settings (SET Button)
The "SET" button is used to access and modify various parameters of the device, such as temperature units (°C/°F) and probe type (NTC/PTC). Specific programming steps will depend on the firmware version. Generally:
- Lyhyt painallus: May display a specific parameter or confirm a selection.
- Pitkä painallus: Typically enters programming mode or saves changes.
Consult the full programming guide for detailed instructions on setting specific parameters, including temperature alarms or calibration, if applicable to your model.
7. Huolto
7.1. Puhdistus
To clean the display unit, gently wipe the surface with a soft, dry, or slightly damp cloth. Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the display or casing.
7.2. Probe Inspection
Periodically inspect the temperature probe and its cable for any signs of damage, wear, or corrosion. Replace the probe if any damage is observed to ensure accurate readings.
8. Vianmääritys
| Ongelma | Mahdollinen syy | Ratkaisu |
|---|---|---|
| Ei näyttöä / Laite ei käynnisty | No power supply; Incorrect wiring (polarity); Faulty unit. | Check 12V DC power connection and polarity. Ensure power source is active. Verify wiring. If problem persists, contact support. |
| Väärä lämpötilalukema | Faulty probe; Incorrect probe type selected; Probe not properly connected; Environmental interference. | Check probe connection. Ensure correct NTC/PTC probe type is configured in settings. Inspect probe for damage. Relocate probe if exposed to external heat sources. |
| Näytöllä näkyy "Err" tai vastaava virhekoodi | Probe disconnected or faulty; Out of temperature range. | Check probe connection and integrity. Ensure measured temperature is within -50°C to +150°C range. |
9. Tekniset tiedot
| Mallinumero | D14012 |
| Merkki | AKO |
| Valmistaja | AKO Electronica |
| Virtalähde | 12V DC |
| Näytön tyyppi | Digitaalinen |
| Lämpötila-alue | -50 °C - +150 °C |
| Anturitulo | NTC Thermistor (PTC selectable) |
| Asennustyyppi | Paneeliasennettava |
| Paneelin leikkauksen mitat | 70.5 mm (leveys) x 28.5 mm (korkeus) |
| Erikoisominaisuudet | Programmable, °C/°F selectable |
10. Takuu ja tuki
For warranty information, technical support, or service inquiries, please contact your local AKO distributor or the point of purchase. Keep your purchase receipt as proof of purchase for warranty claims.