1. Johdanto
The Noyafa NF-909C is a compact and easy-to-use 2-in-1 testing instrument designed for optical fiber networks. It integrates both an optical power meter and an optical light source, making it suitable for absolute optical power measurements and insertion loss tests. This device offers a wide range of power measurement, high accuracy, and stable output, providing a cost-effective solution for fiber optic testing.
2. Turvallisuustiedot
- Lue käsikirja: Before operating the device, thoroughly read and understand this user manual.
- Akun turvallisuus: Use only specified 1.5V batteries (3x AAA). Do not mix old and new batteries or different types of batteries. Remove batteries if the device will not be used for an extended period.
- Laserturvallisuus: The optical light source emits laser radiation. ÄLÄ look directly into the optical output port or into a fiber connected to the light source. Direct exposure to laser light can cause severe eye damage.
- Ympäristöolosuhteet: Operate the device within the specified operating temperature range (-10°C to +60°C). Avoid exposure to extreme temperatures, humidity, or dust.
- Puhdistus: Keep optical connectors clean. Use only approved cleaning methods and materials to avoid damaging the fiber end-faces.
- Huolto: Älä yritä avata tai korjata laitetta. Jätä kaikki huoltotyöt pätevän henkilöstön tehtäväksi.
3. Pakkauksen sisältö
Varmista pakkauksesta purkamisen yhteydessä, että kaikki osat ovat mukana ja hyvässä kunnossa:
- Noyafa NF-909C Fiber Optic Tester Unit
- Käyttöopas
- Protective Cap for Optical Ports
- (Batteries may or may not be included depending on the retailer)
4. Tuote ohiview
The NF-909C features a clear LCD display, intuitive control buttons, and standard optical connectors for versatile use.

Kuva 1: Edessä view of the Noyafa NF-909C Fiber Optic Tester. This image shows the device's display screen, the red control buttons (Power, REF, dBm/W, λ, Hz), and the two optical input/output ports on the front, protected by a red cap. The device is black and red.

Kuva 2: Sivu view of the Noyafa NF-909C Fiber Optic Tester. This image highlights the micro USB port located on the side of the device, which may be used for power or data transfer, though its primary function is typically for charging or external power supply. The red protective cap is shown detached.
Tärkeimmät komponentit:
- LCD-näyttö: Shows measurement readings, selected wavelength, unit, and battery status.
- Ohjauspainikkeet: Power On/Off, Reference (REF), Unit (dBm/W), Wavelength (λ), Frequency (Hz).
- Optical Power Meter Input: Typically supports SC, ST, LC connectors (optional).
- Optical Light Source Output: Typically FC connector (SC, ST, LC optional).
- Akkulokero: Located on the rear, for 3x 1.5V batteries.
- Micro USB -portti: For power supply or charging (refer to Figure 2).
5. Asennus
5.1 Akun asennus
- Paikanna laitteen takaosassa oleva paristolokeron kansi.
- Avaa kansi liu'uttamalla tai irrottamalla sen kiinnitys.
- Insert three (3) 1.5V AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Aseta paristolokeron kansi kunnolla takaisin paikalleen.
5.2 Ensimmäinen käynnistys
Paina ja pidä painettuna Tehoa button to turn on the device. The LCD display will illuminate, showing the current mode and settings.
6. Käyttöohjeet
6.1 Optical Power Meter Mode
This mode measures the absolute optical power or relative loss in optical fiber networks.
- Yhdistä kuitu: Connect the optical fiber to be tested to the Power Meter input port. Ensure the connector is clean.
- Valitse aallonpituus: Paina λ button to cycle through the available calibrated wavelengths: 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm. Select the wavelength matching your light source.
- View Mittaus: Näyttö näyttää optisen tehon dBm:nä.
- Vaihda yksikköä: Paina dBm/W button to switch between dBm and W (Watts) units.
- Set Reference (REF): For relative measurements (loss), connect a known good fiber to a stable light source and the power meter. Press the VIITE button to set the current power reading as the reference (0dB). Subsequent measurements will show the loss relative to this reference.
- Frequency Identification: The power meter can identify modulation frequencies from 10Hz to 60KHz. If the incoming signal is modulated, the frequency will be displayed.
6.2 Optical Light Source Mode
This mode provides a stable optical signal for testing fiber optic cables.
- Yhdistä kuitu: Connect the optical fiber to be tested to the Light Source output port. Ensure the connector is clean.
- Valitse aallonpituus: Paina λ button to cycle through the available wavelengths: 1310nm and 1550nm. Select the desired wavelength.
- Select Modulation Frequency: Paina Hz button to cycle through modulation frequencies: 270Hz, 1KHz, 2KHz, or continuous wave (CW).
- Lähtösignaali: The device will emit a stable optical signal at the selected wavelength and modulation.
6.3 Automaattinen sammutustoiminto
The device features an auto-off function to conserve battery life. If no operation is performed for approximately 15 minutes, the device will automatically power off. Press the Tehoa -painiketta kytkeäksesi sen takaisin päälle.
7. Huolto
- Cleaning Optical Connectors: Always ensure optical connectors are clean before use. Use lint-free wipes and appropriate optical cleaning solutions. Dirty connectors can lead to inaccurate measurements and damage to the device or fiber.
- Akun vaihto: When the battery indicator on the display shows low power, replace all three 1.5V AAA batteries promptly.
- Varastointi: When not in use, store the device in a dry, cool place, away from direct sunlight and extreme temperatures. Always replace the protective caps on the optical ports to prevent dust and damage.
- Ulkoinen puhdistus: Puhdista laitteen ulkopuoli pehmeällä, damp kangas. Älä käytä hankaavia puhdistusaineita tai liuottimia.
8. Vianmääritys
- Laite ei käynnisty:
- Tarkista, että paristot on asennettu oikein ja että napaisuus on oikea.
- Vaihda uusiin paristoihin.
- Inaccurate power meter readings:
- Ensure optical connectors are clean.
- Verify the selected wavelength on the power meter matches the light source wavelength.
- Check if the fiber under test is properly connected and not damaged.
- No light output from light source:
- Ensure the device is powered on and in light source mode.
- Tarkista akun varaustaso.
- Verify the fiber is properly connected to the output port.
- Auto-off activates too quickly:
- The auto-off is fixed at 15 minutes of inactivity. This is normal operation.
9. Tekniset tiedot
| Ominaisuus | Erittely |
|---|---|
| Optical Power Meter Module | |
| Detector Measurement Range | -50 ~ +26 dBm |
| Calibrated Wavelengths | 850, 1300, 1310, 1490, 1550, 1625 nm |
| Resoluutio | 0.01 dBm |
| Identification Frequency Range | 10 Hz ~ 60 KHz |
| Optinen liitin | SC, ST, LC (optional) |
| Optical Light Source Module | |
| Emitter Wavelengths | 1310 / 1550 nm (other wavelengths customizable) |
| Lähtöteho | -7 dBm |
| Tuloksen vakaus | 0.05 dB / 15 mins; 0.1 dB / 8 hours |
| Modulation Frequencies | 270 Hz, 1 KHz, 2 KHz |
| Optinen liitin | FC (SC, ST, LC optional) |
| Yleiset tiedot | |
| Virtalähde | 3 x 1.5 V AAA paristot |
| Automaattinen sammutusaika | 15 minuuttia (n.) |
| Käyttölämpötila | -10°C ~ +60°C |
| Mitat (P x L x K) | 160 x 75 x 32 mm |
| Paino | 400 g (unit only) / 150 g (item weight from specs) |
| Vähimmäiskäyttötilavuustage | 1.5 volttia |
| Suurin käyttötilavuustage | 5 volttia |
| Erittely Met | UL 61010-1, IEC 61010-2-030 |
| Valmistaja | Shenzhen Noyafa Electronic |
10. Takuu ja tuki
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact your authorized Noyafa dealer or the manufacturer directly. Keep your purchase receipt as proof of purchase.





