Reznor EMC-10-AK2-HG7

EMC-10 sähkökaapin lämmityslaitteen käyttöohje

Model: EMC-10-AK2-HG7 | Brand: Reznor

Tuote loppuview

The Reznor EMC-10-AK2-HG7 Electric Cabinet Unit Heater is designed for primary or supplementary heating, or freeze protection in various environments. This 208-volt unit features a two-speed motor and a maximum heat capacity of 34,144 BTU/hr. Its robust construction includes an 18-gauge stainless steel housing, tubular heating elements with fins, and an epoxy/polyester powder paint coating for enhanced corrosion resistance. The unit can be configured for either floor or ceiling mounting, offering flexible installation options.

Reznor EMC-10 Electric Cabinet Unit Heater

Kuva: Edessä view of the Reznor EMC-10 Electric Cabinet Unit Heater, showing its white cabinet, top and bottom grilles, and the "REZNOR" logo in red.

Turvallisuustiedot

Asennus ja asennus

The EMC-10 unit can be installed as a floor-mounted or ceiling-mounted system. Proper installation is crucial for safe and efficient operation. Refer to the detailed installation manual provided with the product for specific mounting instructions, electrical wiring diagrams, and clearance requirements.

Sähköliitäntä

Käyttöohjeet

The EMC-10 Electric Cabinet Unit Heater is equipped with a two-speed motor for flexible heating control. Operation is typically managed via an external thermostat or control system (not included with the unit).

Peruskäyttö

  1. Ensure the unit is properly installed and connected to the power supply.
  2. Set the desired temperature on your external thermostat.
  3. The unit will activate when the ambient temperature falls below the thermostat setting.
  4. The two-speed motor allows for adjustment of airflow and heat distribution. Consult your control system's manual for specific fan speed selection.
  5. The high-temperature control with automatic reset provides an additional safety feature, shutting off the unit if overheating occurs.

Huolto

Regular maintenance ensures optimal performance and longevity of your Reznor EMC-10 unit. Always disconnect power before performing any maintenance.

Vianetsintä

Ennen kuin otat yhteyttä asiakastukeen, tarkistaview seuraavat yleiset ongelmat ja ratkaisut:

OngelmaMahdollinen syyRatkaisu
Yksikkö ei käynnisty.No power supply; tripped circuit breaker; thermostat set too low; safety control activated.Check power connection; reset circuit breaker; adjust thermostat setting; allow unit to cool if safety control tripped.
Riittämätön lämmöntuotto.Blocked grilles; incorrect fan speed; unit undersized for space.Clear obstructions from grilles; ensure proper fan speed setting; consult a professional for sizing verification.
Unusual noises from unit.Loose components; motor issue; debris in fan.Disconnect power and inspect for loose parts; contact a qualified technician for motor inspection.

If the issue persists after attempting these solutions, please contact Reznor customer support.

Tekniset tiedot

Takuutiedot

The Reznor EMC-10 Electric Cabinet Unit Heater comes with a 1 vuoden osien takuu from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. For warranty claims or detailed terms and conditions, please refer to the official warranty document included with your product or contact Reznor customer support.

Asiakastuki

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Reznor customer support. Have your model number (EMC-10-AK2-HG7) and purchase date ready when you call.

Contact information for Reznor can typically be found on their official websivustolla tai tuotepakkauksessa.

Aiheeseen liittyvät asiakirjat - EMC-10-AK2-HG7

Preview Reznor EUHC Sisäkäyttöön/Teollisuuteen tarkoitettu sähkölämmitin - Tekniset tiedot
Reznor EUHC -sähkökäyttöisen kompaktin lämmityslaitteen yksityiskohtaiset tekniset tiedot, mukaan lukien mitat, sähkötiedot, etäisyydet, painot ja asennusohjeet kaupallisiin ja teollisiin sovelluksiin.
Preview Reznor EUH -sarjan sähkölämmittimen tekniset tiedot
Reznor EUH -sarjan sisäkäyttöön tarkoitettujen kaupallisten ja teollisten matalastaattisten aksiaalipuhaltimilla varustettujen sähkövastuslämmittimien kattavat tekniset tiedot, jotka kattavat yksiköiden koot, ominaisuudet, asennuksen, mitat, etäisyydet ja sähkötiedot.
Preview Reznor EGHB Industrial Suspended Unit Heater: Specifications, Features, and Installation Guide
Comprehensive technical specifications, features, installation guidelines, and dimensional data for the Reznor EGHB series industrial suspended electric unit heaters, designed for commercial and industrial spaces.
Preview Reznor LDAP -mallin alasvirtauslämmittimen vaihto-osaopas
Tämä käyttöohje sisältää yksityiskohtaista tietoa Reznorin LDAP-mallin alaspäin suuntautuvien lämmityslaitteiden varaosista. Se kattaa sähkö-, tuuletus-, lämmönvaihtimen, polttimen ja kaapin osat sekä lisävarusteet ja lisävarusteet. Se sisältää sarjanumeron tulkinnan, takuutiedot ja tekniset tiedot erikokoisille yksiköille.
Preview Reznor EHA -sarjan sähkökäyttöisen seinälle asennettavan arkkitehtonisen lämmittimen tekniset tiedot
Reznor EHA -sarjan sisä- ja asuinkäyttöön tarkoitetun sähköisen, seinään asennettavan ilmalämmittimen yksityiskohtaiset tekniset tiedot, jotka kattavat yksiköiden koot, ominaisuudet, asennusvaihtoehdot, tekniset tiedot, mitat ja turvallisuusohjeet.
Preview Reznorin kattoripustussarjan asennusopas sähkö- ja kaasukäyttöisille lämmityslaitteille
Asennusohjeet ja komponenttitiedot Reznor CK22 -kattoripustussarjalle, joka on yhteensopiva EHU-sähkökäyttöisten ja UDXC-, UDX- ja UDZ-kaasukäyttöisten lämmityslaitteiden kanssa. Opi asentamaan Reznor-lämmittimesi turvallisesti.