ResMed SlimLine

ResMed SlimLine -vaihtoletkun käyttöohje

Model: SlimLine

1. Tuote ohiview

The ResMed SlimLine Replacement Tubing is designed to provide a comfortable and efficient continuous positive airway pressure (CPAP) therapy experience. This lightweight and flexible tubing is compatible with ResMed Air10 and S9 series machines, ensuring a reliable connection for your respiratory care needs.

  • Kevyt muotoilu: The SlimLine Non-Heated Tubing is sleek and light for a more comfortable CPAP experience.
  • Compatibility Assured: This CPAP accessory seamlessly fits ResMed Air10 and S9 machines, ensuring a reliable connection.
  • Slim & Flexible: Engineered for space-saving, the slim profile of this CPAP tubing offers greater flexibility and convenience.
  • Durable CPAP Supplies: Constructed to be long-lasting, the authentic ResMed brand SlimLine Air Tubing is a dependable component of your CPAP equipment.
ResMedin logo

Image 1: ResMed Official Logo.

ResMed SlimLine Replacement Tubing

Image 2: The ResMed SlimLine Replacement Tubing, coiled for storage.

2. Asennus ja asennus

Follow these steps to correctly install your ResMed SlimLine Replacement Tubing:

  1. Disconnect Old Tubing: Gently pull the old tubing straight out from the air outlet of your CPAP machine.
  2. Inspect New Tubing: Ensure the new SlimLine tubing is free from any damage or obstructions.
  3. Yhdistä koneeseen: Locate the end of the new tubing with the small chip or slot. Align this chip with the corresponding slot on the air outlet of your ResMed Air10 or S9 machine. Push the tubing in firmly until it is flush and secure.
  4. Yhdistä maskiin: Attach the other end of the tubing to your CPAP mask. Different mask types may have varying connection mechanisms; ensure a secure fit according to your mask's instructions.
ResMed SlimLine Tubing connected to CPAP machine and mask

Image 3: ResMed SlimLine Tubing connected to a CPAP machine.

3. Käyttöohjeet

Once the SlimLine tubing is securely connected to your CPAP machine and mask, you can begin your therapy. Refer to your specific ResMed CPAP machine's user manual for detailed operating instructions, including how to start and stop therapy, adjust settings, and monitor your progress.

  • Ensure all connections are tight before starting therapy to prevent air leaks.
  • Position the tubing to avoid kinks or obstructions that could impede airflow.
  • If using a humidifier, ensure the water chamber is filled to the appropriate level.

4. Huolto ja puhdistus

Regular cleaning of your SlimLine tubing is essential for hygiene and optimal performance. Follow these general guidelines:

  • Päivittäinen siivous: Disconnect the tubing from your machine and mask. Wash the tubing in warm water with a mild soap. Rinse thoroughly with clean water.
  • Kuivaus: Hang the tubing in a clean, dry place away from direct sunlight to air dry completely before reattaching. Ensure no water remains inside the tubing.
  • Tarkastus: Regularly inspect the tubing for any signs of wear, tears, or damage. Replace the tubing if any damage is observed to maintain effective therapy.
  • Korvaus: It is recommended to replace CPAP tubing every 3-6 months, or as advised by your healthcare provider or equipment manufacturer, to ensure optimal hygiene and performance.

5. Vianmääritys

If you encounter issues with your SlimLine tubing, consider the following:

  • Ilmavuotoja: Check all connections between the tubing, machine, and mask. Ensure they are securely fitted. Inspect the tubing for any visible holes or cracks.
  • Alennettu ilmavirtaus: Ensure the tubing is not kinked or obstructed. Check if the tubing is clean and free from debris.
  • Condensation (Rainout): If you experience water buildup in the tubing, consider using a heated humidifier with a heated tube (if your machine supports it and you have the appropriate heated tubing), or a tubing wrap/cover to insulate the air.
  • Epätavalliset äänet: Check for loose connections or damage to the tubing.

If problems persist, consult your healthcare provider or the ResMed customer support.

6. Tekniset tiedot

OminaisuusYksityiskohta
Tuotteen mitat12.28 x 10.08 x 2.36 tuumaa; 3.53 unssia
ValmistajaResMed
ASINB00YFVG9EG
Päivämäärä ensimmäinen saatavilla28. toukokuuta 2015

7. Turvallisuustiedot

Important Safety Warning Regarding Magnets:

Pidä maskin magneetit vähintään 6 mm:n (150 tuuman) turvallisella etäisyydellä implanteista tai lääketieteellisistä laitteista, joihin magneettiset häiriöt voivat vaikuttaa haitallisesti. Tämä varoitus koskee sinua tai ketään, joka on läheisessä fyysisessä kosketuksessa maskisi kanssa. Magneetit ovat rungossa ja alemmissa pääremmien pidikkeissä, joiden magneettikentän voimakkuus on jopa 400 mT. Kun niitä käytetään, ne kiinnittävät maskin, mutta voivat vahingossa irrota nukkuessaan.

Oikeudellinen vastuuvapauslauseke:

Magneettisilla komponenteilla varustetut naamarit ovat vasta-aiheisia potilaille, joilla on seuraavat ominaisuudet:

  • Aktiiviset lääketieteelliset implantit, jotka ovat vuorovaikutuksessa magneettien kanssa (eli sydämentahdistimet, implantoitavat kardiovertteridefibrillaattorit (ICD), neurostimulaattorit, aivo-selkäydinnesteen (CSF) shuntit, insuliini-/infuusiopumput)
  • Metalliset implantit/esineet, jotka sisältävät ferromagneettista materiaalia (esim. aneurysmaklipsit/virtausta häiritsevät laitteet, embolikäämit, stentit, venttiilit, elektrodit, implantit kuulon tai tasapainon palauttamiseksi implantoiduilla magneeteilla, silmäimplantteja, metallisirpaleita silmässä)

8. Takuu ja tuki

For warranty information and customer support, please refer to the documentation provided with your original ResMed CPAP machine or visit the official ResMed websivusto. Säilytä ostokuittisi mahdollisten takuuvaatimusten varalta.