True TRUE988284

True 988284 -lämpötilan säätöpakkaus 077B6856 Käyttöohje

Model: TRUE988284

1. Tuote ohiview

The True 988284 Temperature Control Kit 077B6856 is a genuine Original Equipment Manufacturer (OEM) replacement part designed for True Refrigeration units. This kit ensures the proper regulation of temperature within your commercial refrigeration equipment, maintaining optimal operating conditions for safety, reliability, and performance.

True 988284 Temperature Control Kit with dial and capillary tube

Kuva 1.1: ohiview of the True 988284 Temperature Control Kit, showing the control unit, dial, and capillary tube.

Tärkeimmät ominaisuudet:

2. Turvallisuustiedot

Tärkeää: Read all instructions carefully before installation or operation. Failure to follow these instructions may result in property damage, personal injury, or death.

3. Pakkauksen sisältö

Varmista avatessasi pakkauksen, että kaikki osat ovat mukana ja ehjät.

Components of the True 988284 Temperature Control Kit including control unit, dial, screws, and connectors

Image 3.1: Contents of the True 988284 Temperature Control Kit, typically including the control module, temperature dial, mounting screws, and electrical connectors.

4. Asennusohjeet

This section provides general guidance for replacing a temperature control kit. Specific installation steps may vary depending on your True Refrigeration model. Refer to your unit's service manual for detailed, model-specific instructions.

  1. Katkaise virta: Locate the main power supply to the refrigeration unit and disconnect it. Verify that power is off using a voltage testaaja.
  2. Kulunvalvonta-alue: Depending on your unit, you may need to remove access panels or grilles to reach the existing temperature control.
  3. Dokumentin johdotus: Before disconnecting any wires, take clear photos or make a diagram of the existing wiring connections to the old temperature control. Note the position of the capillary tube sensor.
  4. Poista vanha ohjausobjekti:
    • Carefully disconnect the electrical wires from the old control.
    • Unmount the old control from its housing.
    • Gently remove the capillary tube sensor from its sensing location (e.g., evaporator coil, air return).
  5. Asenna uusi ohjaus:
    • Insert the new capillary tube sensor into the exact same sensing location as the old one. Ensure it is securely positioned for accurate temperature readings. Avoid kinking or damaging the tube.
    • Mount the new temperature control module in the same position as the old one using the provided screws.
    • Connect the electrical wires to the new control according to your documented wiring diagram. Ensure connections are secure.
  6. Kokoa uudelleen: Replace any access panels or grilles that were removed.
  7. Palauta virta: Reconnect the main power supply to the refrigeration unit.
  8. Testitoiminta: Allow the unit to run for a period and monitor the temperature to ensure proper operation and temperature regulation. Adjust the dial as needed.

Huomautus: If you are unsure about any step, consult a qualified refrigeration technician.

5. Käyttöohjeet

The temperature control kit features a rotary dial for adjusting the desired temperature within your True Refrigeration unit.

6. Huolto

The True 988284 Temperature Control Kit is designed for durability and reliability. Regular maintenance of the overall refrigeration unit is crucial for its longevity and efficient operation.

7. Vianmääritys

If your refrigeration unit is experiencing temperature issues after installing this kit, consider the following common troubleshooting steps:

OngelmaMahdollinen syyRatkaisu
Unit not cooling or too warm
  • Temperature dial set too high (warmer)
  • Capillary tube not properly seated or damaged
  • Löysä sähköliitäntä
  • Other refrigeration system issues (e.g., low refrigerant, dirty condenser)
  • Adjust dial to a colder setting.
  • Verify capillary tube placement and condition.
  • Check and secure all wiring connections (with power disconnected).
  • Consult a qualified technician for system diagnosis.
Unit freezing contents or too cold
  • Temperature dial set too low (colder)
  • Capillary tube sensing incorrect temperature (e.g., too close to evaporator)
  • Ohjausyksikön toimintahäiriö
  • Adjust dial to a warmer setting.
  • Ensure capillary tube is correctly positioned away from direct evaporator contact if applicable.
  • If issues persist, the control unit may require replacement or further diagnosis by a technician.
Lämpötila vaihtelee suuresti
  • Improper capillary tube placement
  • Ohjausyksikön toimintahäiriö
  • Refrigeration system issues
  • Verify capillary tube placement.
  • Ota yhteyttä pätevään teknikkoon vianmääritystä varten.

Varoitus: Do not attempt repairs beyond your technical capabilities. Always prioritize safety and consult a professional for complex issues.

8. Tekniset tiedot

OminaisuusYksityiskohta
MerkkiTotta
MallinumeroTOSI988284
Tuotteen mitat6 x 6 x 4 tuumaa
Tuotteen paino4.8 unssia
ToimintatilaAutomaattinen
Yhteyden tyyppiNormaalisti auki
Liittimen tyyppiRuuviliittimet
TerminaaliRuuvi
Piirin tyyppi1-suuntainen
AsennustyyppiPinta-asennus
Toimilaitteen tyyppiPainike
YhteysmateriaaliKupari, messinki
Päivämäärä ensimmäinen saatavilla15. kesäkuuta 2011

9. Takuu ja tuki

As a genuine OEM part, this True 988284 Temperature Control Kit is manufactured to high standards. For specific warranty information, please refer to the documentation provided with your original True Refrigeration unit or contact True Refrigeration directly.

Asiakastuki:

For technical assistance, troubleshooting beyond this manual, or to inquire about warranty claims, please contact True Refrigeration customer support or an authorized service provider.

Aiheeseen liittyvät asiakirjat - TOSI988284

Preview True Kommerzielle Kühltechnik: Allgemeiner Regelungsleitfaden
Umfassender Leitfaden zur Bedienung, Einstellung und Fehlerbehebung von Temperaturregelungen in True kommerziellen Kühl- und Gefriergeräten. Enthält Anleitungen für mechanische und elektronische Steuerungen sowie spezifische Modellinformationen.
Preview TRUE Manufacturingin asennusopas Pikaopas
Tämä asiakirja sisältää TRUE Manufacturingin kaupallisten jäähdytys- ja lämmityslaitteiden olennaiset asennus-, käyttö- ja huolto-ohjeet. Se sisältää turvallisuusvaroituksia, teknisiä tietoja, asennusmenettelyjä ja hoito-ohjeita.
Preview True TH -mallien lämmitettyjen kaappien asennusohje
Kattava asennus-, käyttö- ja huolto-opas True TH -mallien lämmitettyihin kaappeihin. Kattaa True Manufacturing Co., Inc:n turvallisuus-, sähkö-, asennus-, hoito- ja takuutiedot.
Preview True T-23DF-HC kaupallisen jääkaapin/pakastimen asennus- ja käyttöohje
Kattava asennus-, käyttö-, huolto- ja turvallisuusopas True T-23DF-HC -kaksikammioiselle kaupalliselle jääkaappi-pakastimelle. Sisältää vianmääritys-, puhdistusohjeet ja takuutiedot.
Preview True CVM -sarjan asennusopas
Kattava asennus-, käyttö- ja huolto-opas True CVM -sarjan kylmälaitteille. Käsittelee turvaohjeita, sähkövaatimuksia, asennusmenetelmiä, tasausta, tiivistystä, hyllyasennusta ja yleistä huoltoa.
Preview Manuel d'Installation et de Démarrage Rapide True
True Manufacturing Co., Inc.:n täydellinen asennus-, käyttö- ja laitevalmistus- ja jäähdytyslaitteiden asennus- ja käyttöopas True Manufacturing Co., Inc. Sisältää tarvittavat tiedot ja tukiresurssit.