Johdanto
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Astral Pool Victoria Plus Pool Pump. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product.
Key features of the Astral Pool Victoria Plus Pool Pump include:
- Simple and sturdy design with an easy-to-use pre-filter nut.
- Silent operation, enhanced by integrated rubber feet.
- Motor protection class IP-55, ensuring durability and safety.
- Equipped with a large capacity pre-filter basket for efficient debris collection.

Figure 1: Astral Pool Victoria Plus Pool Pump. This image displays the complete pool pump unit, highlighting its compact design, the motor housing on the left, and the pre-filter basket with its transparent lid on the right. The inlet and outlet connections are also visible.
Asennus ja asennus
Proper installation is crucial for the pump's performance and safety. It is recommended that installation be performed by a qualified professional.
1. Paikan valinta
- Install the pump in a dry, well-ventilated area, protected from direct sunlight and rain.
- Ensure the location allows for easy access for maintenance and servicing.
- The pump should be installed as close to the pool as possible to minimize friction loss in the plumbing.
- Ensure the base is level and stable to prevent vibration and noise. The integrated rubber feet help with silent operation.
2. Putkiliitännät
- Connect the suction line from the pool to the inlet port of the pump (typically the side port).
- Connect the discharge line to the outlet port (typically the top port) leading to the filter system.
- Use appropriate PVC fittings and solvent cement for secure, leak-free connections.
- Ensure all connections are tight but do not overtighten plastic fittings.
3. Sähköliitäntä
- Varmista, että virtalähde voltage vastaa pumpun vaatimuksia (230 volttia).
- All electrical wiring must comply with local electrical codes and regulations.
- Pumpun on oltava kunnolla maadoitettu.
- Install a suitable circuit breaker or fuse for motor protection. The motor protection class is IP-55.
Käyttöohjeet
Follow these steps for safe and effective operation of your pool pump.
1. Pumpun täyttö
- Ensure the pool water level is adequate.
- Open all suction and return valves in the plumbing system.
- Remove the pre-filter basket lid by unscrewing the pre-filter nut.
- Fill the pre-filter basket with water until it overflows.
- Replace the pre-filter basket lid and tighten the nut securely to prevent air leaks.
- Turn on the pump. The pump should prime within a few minutes. If not, turn it off, re-prime, and check for air leaks.
2. Normaali käyttö
- Once primed, the pump will circulate water through the filter system.
- Monitor the pressure gauge on your filter (if applicable) to ensure proper flow.
- Pumppu on suunniteltu jatkuvaan käyttöön suodatussyklien aikana.
3. Pumpun sammuttaminen
- Turn off the power to the pump at the circuit breaker or switch.
- Close any necessary valves if performing maintenance or winterizing.
Huolto
Säännöllinen huolto varmistaa pumpun optimaalisen suorituskyvyn ja pidentää sen käyttöikää.
1. Esisuodattimen korin puhdistaminen
- Turn off the pump and close any necessary valves to prevent water flow.
- Unscrew the pre-filter nut and remove the lid.
- Lift out the pre-filter basket and empty any debris.
- Huuhtele kori huolellisesti vedellä.
- Tarkista kannen O-rengas halkeamien tai kulumisen varalta. Vaihda tarvittaessa.
- Place the basket back into the housing, ensuring it is seated correctly.
- Replace the lid and tighten the pre-filter nut securely.
- Re-prime the pump as described in the "Operating Instructions" section.
2. Motor Care
- Keep the motor free from dirt, dust, and debris to ensure proper ventilation.
- Do not spray water directly onto the motor.
- Tarkista, ettei käytön aikana kuulu epätavallisia ääniä tai tärinää.
3. talvehtiminen
- In areas subject to freezing temperatures, the pump must be drained and protected.
- Turn off power to the pump.
- Drain all water from the pump by removing the drain plugs (if applicable) or disconnecting plumbing.
- Säilytä pumppua kuivassa ja pakkaselta suojatussa paikassa tai peitä se riittävästi, jos se jää asennettuna.
Vianetsintä
Tässä osiossa on ratkaisuja yleisiin ongelmiin, joita saatat kohdata.
| Ongelma | Mahdollinen syy | Ratkaisu |
|---|---|---|
| Pumppu ei käynnisty | No power; tripped breaker; faulty wiring; motor issue. | Check power supply, reset breaker, inspect wiring, consult a qualified electrician. |
| Pumppu käy, mutta ei ime tai sen virtaus on heikko | Air leak in suction line; clogged pre-filter basket; low water level; closed valves. | Check all connections for leaks, clean pre-filter basket, ensure adequate pool water level, open all valves. |
| Liiallinen melu tai tärinä | Air in system; cavitation; worn bearings; loose mounting. | Re-prime pump, check for obstructions in plumbing, ensure pump is securely mounted. If noise persists, contact service. |
| Pumpusta vuotaa vettä | Loose connections; worn O-rings or seals; cracked housing. | Tighten connections, inspect and replace O-rings/seals, contact service for housing damage. |
Tekniset tiedot
Detailed technical specifications for the Astral Pool Victoria Plus Pool Pump.
| Attribuutti | Arvo |
|---|---|
| Merkki | Astralpool |
| Mallinumero | part_B00J0CT5FK |
| Valmistaja | ASTRAL |
| Tuotteen mitat | 64 x 27 x 41 cm |
| Tuotteen paino | 14.3 kiloa |
| Koko | 1.5 CV |
| Väri | blackone |
| Tyyli | klassista |
| Materiaali | Polypropeeni (PP) |
| Virtalähteen tyyppi | Johdollinen sähkö |
| Voitage | 230 volttia |
| Tuote Paketin määrä | 1 |
| Virtausnopeus | 24 Cubic Metres Per Hour |
| Motor Protection Class | IP-55 |
Takuu ja tuki
For warranty information and technical support, please refer to the official Astralpool websivustolta tai ota yhteyttä suoraan heidän asiakaspalveluunsa. Säilytä ostokuitti ostotodistuksena mahdollisten takuuvaatimusten varalta.