Ecolink TILT-ZWAVE2-ECO

Ecolink Z-Wave -kallistusanturin (TILT-ZWAVE2-ECO) käyttöohje

Johdanto

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Ecolink Z-Wave Tilt Sensor (TILT-ZWAVE2-ECO). This device is designed to monitor the tilt status of objects, primarily garage doors, and communicate this status wirelessly via Z-Wave technology to a compatible smart home hub. Ensure you read these instructions thoroughly before installation and use.

Tuote loppuview

Ecolink Z-Wave Tilt Sensor, front view

Kuva 1: Edessä view of the Ecolink Z-Wave Tilt Sensor. The sensor is a compact, white rectangular device with a small black indicator light on its front surface.

Tärkeimmät ominaisuudet

Pakkauksen sisältö

Asennus

1. Akun asennus

  1. Remove the back cover of the sensor by gently prying it open or sliding it off, depending on the model.
  2. Insert the included CR123 lithium battery, observing the correct polarity (+/-).
  3. Replace the back cover, ensuring it clicks securely into place. The sensor's LED may flash briefly to indicate power.

2. Z-Wave-yhteyden muodostaminen (pariliitos)

To integrate the sensor into your Z-Wave network, follow these steps:

  1. Aseta Z-Wave-keskitin pariliitostilaan. Katso tarkemmat vaiheet keskittimen käyttöoppaasta.
  2. With the sensor powered on, press the tamper switch (located inside the sensor, often a small button or lever) once. The sensor's LED will flash to indicate it is attempting to pair.
  3. If inclusion is successful, the LED will stop flashing, and your Z-Wave hub should confirm the new device.
  4. If inclusion fails, the LED may flash rapidly or remain off. Try repeating the process or performing an exclusion first.

3. Z-Wave-poissulkeminen (parituksen purkaminen)

To remove the sensor from your Z-Wave network:

  1. Place your Z-Wave hub into exclusion (unpairing) mode. Refer to your hub's instruction manual for specific steps.
  2. Paina tamper switch on the sensor once. The sensor's LED will flash to indicate it is attempting to unpair.
  3. If exclusion is successful, the LED will stop flashing, and your Z-Wave hub should confirm the device has been removed.

4. Anturin asentaminen

The sensor can be mounted using screws or double-sided adhesive tape. For garage doors, mount the sensor on the top panel of the garage door, ensuring it changes orientation (tilts) when the door opens or closes.

Käyttöohjeet

Kallistuksen tunnistus

The Ecolink Z-Wave Tilt Sensor detects changes in its physical orientation. When mounted correctly on a garage door, it will report an "open" status to your Z-Wave hub when the door is open (sensor is horizontal) and a "closed" status when the door is closed (sensor is vertical). This status is communicated wirelessly to your Z-Wave network, allowing for automation and notifications.

External Contact Input

The sensor includes an external contact input. This allows you to connect a separate wired normally-closed (NC) or normally-open (NO) contact sensor (e.g., a magnetic reed switch) to the tilt sensor. When the external contact changes state, the tilt sensor will report this status to your Z-Wave hub. This feature can be used for monitoring a secondary point or for applications where a tilt sensor is not suitable.

Huolto

Akun vaihto

The Ecolink Z-Wave Tilt Sensor uses one CR123 lithium battery. When the battery level is low, your Z-Wave hub should report a low battery warning. To replace the battery:

  1. Remove the sensor from its mounting bracket or detach it from the adhesive.
  2. Open the back cover of the sensor.
  3. Poista vanha CR123-paristo varovasti.
  4. Aseta uusi CR123-litiumparisto paikalleen varmistaen oikean napaisuuden.
  5. Replace the back cover and re-mount the sensor.
  6. It may be necessary to wake up the sensor or refresh its status on your Z-Wave hub after battery replacement to update the battery level.

Huomautus: Hävitä vanhat paristot paikallisten määräysten mukaisesti.

Vianetsintä

OngelmaMahdollinen syy / Ratkaisu
Sensor does not pair with Z-Wave hub.
  • Ensure the Z-Wave hub is in inclusion mode.
  • Verify the sensor has a fresh battery and is powered on.
  • Perform a Z-Wave exclusion on the sensor first, then attempt inclusion again.
  • Move the sensor closer to the Z-Wave hub during the pairing process.
Sensor reports incorrect status (e.g., always open/closed).
  • Check the mounting orientation. The sensor must clearly tilt between open and closed states.
  • Varmista, että anturi on tukevasti kiinnitetty eikä liiku.
  • Verify the internal tilt mechanism is not obstructed or damaged.
Lyhyt akunkesto.
  • Ensure a high-quality CR123 lithium battery is used.
  • Frequent reporting (e.g., if the door is opened/closed many times a day) can reduce battery life.
  • Äärimmäiset lämpötilat voivat vaikuttaa akun suorituskykyyn.
Sensor loses connection to Z-Wave hub.
  • Check the distance between the sensor and the Z-Wave hub or nearest Z-Wave repeater.
  • Ensure there are no new sources of interference (e.g., large metal objects, other wireless devices).
  • Perform a Z-Wave network heal or repair from your hub's interface.

Tekniset tiedot

AttribuuttiYksityiskohta
MallinumeroTILT-ZWAVE2-ECO
Langaton tekniikkaZ-Wave
Virtalähde1 x CR123 litiumparisto (mukana)
Akun kestoJopa 5 vuotta (tyypillinen käyttö)
Mitat (P x L x K)3.0 x 1.7 x 1.0 tuumaa (7.62 x 4.32 x 2.54 cm)
Paino2.89 unssia (81.9 g)
MateriaaliAkryylinitriilibutadieenistyreeni (ABS)
AsennustyyppiDoor Mount (Screws or Adhesive)
ToimintaympäristöVain sisäkäyttöön
Sensing Distance (Z-Wave Range)Up to 100 feet (30 meters) line of sight, varies with environment
UPC851166005022

Takuu ja tuki

Ecolink products are designed for reliability and performance. For specific warranty information, please refer to the warranty card included with your product or visit the official Ecolink website. For technical support, troubleshooting assistance, or further inquiries, please contact Ecolink customer service through their official channels.

Ecolink Official Websivusto: Käy Ecolink-kaupassa Amazonissa