1. Johdanto ja loppuview
This manual provides essential instructions for the safe and effective use of your BriskHeat Full-Coverage Drum Heater, Model FGDHC55120D. This industrial-grade heater is designed for 55-gallon drums, offering solutions for viscosity control, freeze protection, temperature maintenance, and heating contents to a desired temperature. Its robust construction, high wattage, and efficient insulation ensure reliable performance.

Image 1: BriskHeat Full-Coverage Drum Heater (Model FGDHC55120D) installed on a drum. This image illustrates the heater's full-coverage design and integrated control box.
2. Turvallisuustiedot
Read and understand all safety warnings and instructions before operating this drum heater. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Sähköturvallisuus: Ensure the power source matches the heater's voltage (120 Volts). Do not operate with damaged cords or plugs. Always connect to a grounded outlet.
- Syttyvät materiaalit: Do not use this heater with drums containing highly flammable liquids or in environments with explosive atmospheres unless specifically rated for such use. Consult material safety data sheets (MSDS) for contents.
- Ylikuumeneminen: Do not cover the heater's control unit or restrict airflow around the drum. Monitor the temperature to prevent overheating of drum contents.
- Sijoitus: Ensure the drum and heater are placed on a stable, non-combustible surface. The heater is designed for floor mount applications.
- Huolto: Katkaise virta ennen minkään huollon tai puhdistuksen suorittamista.
3. Pakkauksen sisältö
Varmista, että kaikki osat ovat mukana purkaessasi pakkauksesta:
- 1 x BriskHeat Full-Coverage Drum Heater (Model FGDHC55120D)
- Käyttöohje (tämä asiakirja)
4. Asennus ja asennus
The BriskHeat Full-Coverage Drum Heater is designed for easy installation on standard 55-gallon drums.
- Valmistele rumpu: Ensure the 55-gallon drum is clean, dry, and free from any sharp edges that could damage the heater's fabric.
- Aseta lämmitin: Carefully wrap the heater around the drum, ensuring it covers the drum's circumference evenly. The heater is designed for floor mount applications, so ensure the drum is on a stable surface.
- Secure the Heater: Use the integrated fastening system (e.g., straps or buckles) to secure the heater snugly around the drum. Ensure there are no gaps or loose areas that could compromise heating efficiency.
- Liitä virta: Plug the heater's power cord into a grounded 120 Volt electrical outlet. Ensure the outlet can handle the heater's 1600 Watts power consumption.
5. Käyttöohjeet
The BriskHeat drum heater features an integrated control system for temperature management.
- Virta päälle: Once plugged in, the heater is ready for operation. The control unit will typically display the current temperature or be ready for programming.
- Aseta lämpötila: Use the controls on the integrated unit to set the desired temperature for the drum contents. Refer to the specific instructions on the control unit for detailed programming steps.
- Monitorin toiminta: The heater will begin to warm the drum contents. Periodically monitor the temperature and the heater's operation to ensure it is functioning as expected.
- Virta pois: To turn off the heater, either unplug it from the power source or use the power control on the integrated unit, if available.

Kuva 2: Lähikuva view of the control box on the BriskHeat Full-Coverage Drum Heater. This box houses the temperature controls and power connection.
6. Huolto
Proper maintenance ensures the longevity and safe operation of your drum heater.
- Puhdistus: Disconnect power before cleaning. Wipe the exterior of the heater with a damp cloth. Do not immerse the heater in water or use abrasive cleaners.
- Tarkastus: Regularly inspect the heater for any signs of wear, tear, cuts, or damage to the fabric, power cord, or control unit. Do not operate a damaged heater.
- Varastointi: When not in use, store the heater in a clean, dry place, away from direct sunlight and extreme temperatures. Ensure it is properly coiled or folded to prevent damage to internal heating elements.
7. Vianmääritys
If you encounter issues with your BriskHeat drum heater, refer to the following common troubleshooting steps:
- Lämmitin ei käynnisty:
- Tarkista, että virtajohto on kytketty kunnolla toimivaan 120 V:n pistorasiaan.
- Varmista, että pistorasian sulake tai sulake ei ole lauennut.
- Tarkista virtajohto näkyvien vaurioiden varalta.
- Heater Not Reaching Desired Temperature:
- Ensure the temperature setting on the control unit is correct.
- Verify the heater is snugly fitted around the drum to minimize heat loss.
- Check for drafts or cold ambient temperatures that may affect heating efficiency.
- Ensure the drum contents are not excessively cold or require a longer heating time.
- Epätavalliset hajut tai savu: Immediately disconnect power and cease operation. Contact BriskHeat customer support.
8. Tekniset tiedot
| Attribuutti | Yksityiskohta |
|---|---|
| Valmistaja | BriskHeat |
| Osanumero | 2950106 |
| Tuotteen paino | 25 kiloa |
| Tuotteen mallinumero | FGDHC55120D |
| Koko | Large (for 55-gallon drums) |
| Virtalähde | Johdollinen sähkö |
| Voitage | 120 volttia |
| Wattage | 1600 wattia |
| Tuote Paketin määrä | 1 |
| Asennustyyppi | Lattiakiinnike |
| ASIN | B00GE9LSO8 |
| Päivämäärä ensimmäinen saatavilla | 30. huhtikuuta 2015 |
9. Takuu ja tuki
For warranty information, technical support, or service inquiries, please contact BriskHeat directly. Keep your purchase receipt and model number (FGDHC55120D) handy when contacting support.
BriskHeat Contact Information:
Please refer to the official BriskHeat webKatso ajantasaisimmat yhteystiedot sivustolta tai tuotepakkauksesta.