The Dwyer Series WMT2 Multi-Jet Water Meter is engineered for commercial and industrial applications requiring accurate water flow measurement. Its multi-jet design ensures reliable performance and accuracy across a broad range of flow rates, including low-flow conditions. The meter is built for durability and minimal maintenance, even in challenging environments. It features a magnetically driven, hermetically sealed register that prevents leaks and fogging, completely isolating it from the water flow. A reed switch, activated by a magnet on the dial, generates a pulsed output directly proportional to the flow rate. This output is suitable for remote monitoring of flow rate or totalization and can be integrated with PLCs, counters, data loggers, and SCADA systems.

Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter with Pulsed Output

Image 1.1: The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter, showing its brass body, blue casing, and the meter face with a pulsed output connection.

2. Turvallisuustiedot

WARNING: This product is NOT FOR POTABLE WATER USE. The brass construction contains lead in excess of low-lead limits. Do not use this meter in applications where water will be consumed by humans or animals.

Always ensure proper installation by qualified personnel to prevent leaks and ensure accurate operation. Adhere to all local codes and regulations regarding plumbing and electrical connections.

3. Tuotteen ominaisuudet

  • Multi-Jet Design: Provides high accuracy and wide flow range capabilities.
  • Pulsed Output: Equipped with a reed switch for remote monitoring and integration with control systems.
  • Hermetically Sealed Register: Magnetically driven, preventing leaks and fogging for clear readings.
  • Kestävä rakenne: Designed for long service life in commercial and industrial settings.
  • Messinkirunko: Robust construction for demanding applications.

4. Tekniset tiedot

ErittelyArvo
MalliWMT2-B-C-11-1
Kytkimen koko1" BSPT
Suurin virtausnopeus7 m³/h
Nimellinen virtausnopeus0.25-3.5 m³/h
Transitional Flow Rate0.07 m³/h
Pulssi1 gallon per pulse
Maksimilämpötila104 °F (40 °C)
Maksimipaine232 psi (16 bar)
SähköliitännätColor-coded lead wires, 4.5' (1.5 m) long
Tuotteen paino13.52 puntaa
ValmistajaDwyer Instruments, Inc.

5. Asennus ja asennus

Installation of the Dwyer WMT2-B-C-11-1 water meter should be performed by a qualified professional in accordance with all applicable local and national plumbing and electrical codes.

  1. Paikan valinta: Choose a location that is easily accessible for reading and maintenance, protected from freezing temperatures, and where the meter can be installed horizontally with the flow arrow pointing in the direction of water flow.
  2. Putken valmistelu: Ensure the piping is clean and free of debris before installation. Use appropriate pipe thread sealant on the 1" BSPT couplings.
  3. Mekaaninen asennus: Install the meter into the pipeline, ensuring a tight, leak-free connection. The meter should be installed in a straight run of pipe, ideally with at least 10 pipe diameters of straight pipe upstream and 5 pipe diameters downstream for optimal accuracy.
  4. Sähköliitäntä: Connect the color-coded lead wires from the pulsed output to your remote monitoring system (PLC, counter, data logger, SCADA). Refer to your system's documentation for specific wiring requirements. Ensure all electrical connections are secure and properly insulated.
  5. Vuototarkistus: After installation, slowly open the water supply to the meter and check for any leaks at the connections.

6. Käyttöohjeet

Once installed and the water supply is restored, the Dwyer WMT2-B-C-11-1 meter will begin measuring water flow. The meter's register displays the totalized volume of water that has passed through it. The pulsed output provides an electrical signal (1 pulse per gallon) that can be used by external devices for remote monitoring and data logging.

  • Reading the Meter: The main display on the meter face shows the total accumulated volume. Smaller dials may indicate fractional units for more precise readings.
  • Pulsed Output: The reed switch generates a pulse for every gallon of water that flows through the meter. Connect the lead wires to a compatible device (e.g., PLC, counter) to record these pulses and calculate flow rate or total volume remotely.
  • Virtaussuunta: Ensure water flows in the direction indicated by the arrow on the meter body for accurate measurement.

7. Huolto

The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter is designed for relatively maintenance-free operation. However, periodic checks are recommended to ensure continued accuracy and performance:

  • Silmämääräinen tarkastus: Regularly inspect the meter for any signs of physical damage, leaks, or corrosion.
  • Register Clarity: Ensure the hermetically sealed register remains clear and free of fogging, allowing for easy reading.
  • Yhteyden eheys: Verify that all plumbing and electrical connections remain secure and free of corrosion.
  • Puhdistus: If the exterior of the meter becomes dirty, wipe it with a damp kangas. Älä käytä voimakkaita kemikaaleja tai hankaavia puhdistusaineita.

No internal user-serviceable parts are present. Do not attempt to disassemble the meter, as this will void the warranty and may damage the device.

8. Vianmääritys

If you encounter issues with your Dwyer WMT2-B-C-11-1 water meter, consider the following troubleshooting steps:

  • No Flow Reading:
    • Check if water is actually flowing through the pipe.
    • Verify the meter is installed with the flow arrow in the correct direction.
    • Inspect for any blockages upstream or downstream of the meter.
  • Epätarkkoja lukemia:
    • Ensure the meter is installed horizontally.
    • Check for air in the pipeline, which can affect accuracy.
    • Verify that the flow rate is within the meter's specified nominal flow range.
  • No Pulsed Output:
    • Confirm that water is flowing through the meter and the mechanical register is advancing.
    • Check the electrical connections of the lead wires to your monitoring device.
    • Ensure the monitoring device is correctly configured to receive pulses.
  • Vuodot liitoksissa:
    • Tighten connections carefully, ensuring not to overtighten.
    • If necessary, drain the system, reapply pipe thread sealant, and reassemble.

If problems persist after performing these checks, contact Dwyer Instruments, Inc. technical support for assistance.

9. Takuu ja tuki

For information regarding the product warranty, technical support, or replacement parts, please contact Dwyer Instruments, Inc. directly or visit their official website. Keep your purchase receipt and product model number (WMT2-B-C-11-1) readily available when seeking support.

Aiheeseen liittyvät asiakirjat - WMT2-B-C-11-1

Preview Dwyer-sarjan 477AV-kädessä pidettävä digitaalinen manometri: Tekniset tiedot, asennus ja käyttöohjeet
Kattava opas Dwyer-sarjan 477AV-kädessä pidettävään digitaaliseen manometriin, joka kattaa paineen, virtauksen ja nopeuden mittaamisen tekniset tiedot, asennuksen, käyttöohjeet, ominaisuudet ja huollon.
Preview Dwyer-sarjan IEF-insertion-sähkömagneettinen virtauslähetin: Asennus- ja käyttöohjeet
Tämä asiakirja sisältää kattavat tekniset tiedot, asennusoppaat ja käyttöohjeet Dwyer-sarjan IEF-insertion-sähkömagneettiselle virtauslähettimelle, ja siinä kuvataan yksityiskohtaisesti sen ominaisuudet, sovellukset ja tiedonsiirtoprotokollat ​​teollisuuden nesteen nopeuden mittaamiseen.
Preview Dwyerin virtausmittaus- ja säätötuotteet: Kattava valintaopas
Tutustu Dwyer Instrumentsin laajaan virtausmittarien, virtauskytkimien ja virtauslähettimien valikoimaan. Tämä opas sisältää yksityiskohtaiset tiedot ja valintakriteerit, jotka auttavat tunnistamaan optimaalisen tuotteen teolliseen tai kaupalliseen sovellukseesi.
Preview Dwyer-sarjan VFC Visi-Float -virtausmittarien pikaopas
Dwyer-sarjan VFC Visi-Float -virtausmittareiden pikaopas, joka sisältää tärkeät asennus-, kiinnitys- ja lukuohjeet sekä tärkeitä käyttöä koskevia varoituksia.
Preview Dwyer-sarjan TUF-ultraäänienergiamittarit: Virtaus- ja lämpötilanvalvonta
Dwyer-sarjan TUF-ultraäänienergiamittareiden yksityiskohtaiset tekniset tiedot, ominaisuudet, sovellukset ja tilaustiedot. Mittarit on suunniteltu tarkkaan virtauksen ja lämpötilan valvontaan Modbus®- tai BACnet-tiedonsiirrolla.
Preview Dwyer Process Automation -tuotesovellukset ja valintaoppaat
Tutustu Dwyer Instrumentsin kattavaan prosessiautomaatiooppaaseen, joka kattaa tuotesovellukset ja -valinnat LVI-alalle, vedenkäsittelyyn, öljy- ja kaasuteollisuuteen sekä muuhun. Tutustu instrumentointiratkaisuihin paineen, virtauksen, pinnankorkeuden, lämpötilan ja ilmanlaadun mittaamiseen.