Johnson Controls V-9012-1

Johnson Controlsin V-9012-1 solenoidiventtiilireleen käyttöohje

Model: V-9012-1

1. Johdanto

This manual provides detailed instructions for the installation, operation, and maintenance of the Johnson Controls V-9012-1 E/P Solenoid Relay. This device is designed to convert an electrical signal into a pneumatic output, controlling air pressure based on a 12 VDC input. Please read this manual thoroughly before attempting any installation or operation to ensure safe and efficient use of the product.

2. Turvallisuustiedot

Adherence to safety precautions is crucial for preventing injury and damage to the equipment. Always follow local codes and regulations.

  • Pätevä henkilöstö: Installation and servicing must be performed by qualified and experienced personnel only.
  • Sähköturvallisuus: Disconnect all power to the device and associated equipment before performing any wiring or maintenance. Ensure proper grounding.
  • Pneumatic Safety: Depressurize all pneumatic lines before making or breaking connections. Wear appropriate personal protective equipment.
  • Ympäristöolosuhteet: Do not expose the device to conditions outside its specified operating range (temperature, humidity, pressure).

3. Tuote ohiview

The Johnson Controls V-9012-1 is an Electro-Pneumatic (E/P) Solenoid Relay that converts a 12 VDC electrical input into a pneumatic control signal. It is commonly used in industrial applications to manage air pressure for actuators or other pneumatic devices.

3.1. Tärkeimmät ominaisuudet

  • 12 VDC Input for electrical control.
  • Solenoid Valve functionality for precise pneumatic regulation.
  • Relay operation for switching pneumatic states.
  • Maximum input current of 50 mA.

3.2. Komponentit ja merkinnät

Refer to the image below for a visual representation of the V-9012-1 Solenoid Valve Relay and its key labeled components.

Johnson Controls V-9012-1 E/P Solenoid Relay with labels

Figure 1: Johnson Controls V-9012-1 E/P Solenoid Relay

The image displays the Johnson Controls V-9012-1 E/P Solenoid Relay. Key labels visible on the device include:

  • V-9012-1 E/P SOLENOID RELAY: Identifies the model and type of device.
  • PAT 4,770,200 and PAT 4,804,009: Patent numbers associated with the product.
  • BO TERM. 1 (RED): Indicates the first electrical terminal, typically for the positive 12 VDC input.
  • 12 V.D.C. INPUT (50 mA. MAX.): Specifies the required input voltage ja maksimivirta.
  • BO TERM. 2 (BLK) RESISTOR: Indicates the second electrical terminal, typically for the negative connection, and notes the presence of a resistor.
  • TOIMITTAA: The inlet port for the pneumatic supply pressure.
  • ACTUATOR: The outlet port for the controlled pneumatic pressure to the actuator.
  • +12 V.D.C. PRESS.: Indicates that a +12 VDC input results in a 'PRESS' (pressure) state.
  • 0 V.D.C. HOLD: Indicates that 0 VDC input results in a 'HOLD' state.
  • -12 V.D.C. EXHAUST: Indicates that a -12 VDC input results in an 'EXHAUST' state.

4. Asennus ja asennus

Proper installation is critical for the correct functioning of the V-9012-1 Solenoid Relay.

4.1. Asennusta edeltävät tarkastukset

  • Verify that the power supply matches the device's requirements (12 VDC).
  • Inspect the device for any visible damage from shipping.
  • Ensure all necessary tools and fittings are available.

4.2. Asennus

Mount the solenoid relay securely in a location that is free from excessive vibration, moisture, and extreme temperatures. Ensure adequate space for wiring and pneumatic connections.

4.3. Kytkentäohjeet

Noudata näitä ohjeita sähköliitäntöjen yhteydessä:

  1. Ensure the power source is completely disconnected.
  2. Connect the positive (+) 12 VDC power supply wire to BO TERM. 1 (RED).
  3. Connect the negative (-) 12 VDC power supply wire to BO TERM. 2 (BLK). Note that this terminal includes a resistor.
  4. Varmista, että kaikki liitännät ovat tukevat ja asianmukaisesti eristettyjä.

4.4. Pneumaattiset liitännät

Follow these steps for pneumatic connections:

  1. Connect the main pneumatic supply line to the port labeled TOIMITTAA. Ensure the supply pressure is within the device's specified operating range.
  2. Connect the line leading to the pneumatic actuator or controlled device to the port labeled TOIMILAITE.
  3. Check all pneumatic connections for leaks after pressurizing the system.

5. Käyttö

The V-9012-1 Solenoid Relay operates based on the applied electrical input voltage, controlling the pneumatic output to the actuator.

  • +12 VDC Input: When a positive 12 VDC is applied to the input terminals, the relay will enter a 'PRESS' state, allowing supply pressure to flow to the actuator.
  • 0 VDC Input: When 0 VDC (no voltage) is applied, the relay will enter a 'HOLD' state, maintaining the current pneumatic output.
  • -12 VDC Input: When a negative 12 VDC is applied, the relay will enter an 'EXHAUST' state, releasing pressure from the actuator.

Ensure that the control system provides the correct voltage signals for the desired pneumatic response.

6. Huolto

The Johnson Controls V-9012-1 Solenoid Relay is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure longevity and optimal performance.

  • Rutiinitarkastus: Periodically inspect the device for any signs of wear, corrosion, or damage to the housing, wiring, and pneumatic connections.
  • Puhdistus: Keep the exterior of the device clean and free from dust and debris. Do not use harsh chemicals or abrasive cleaners.
  • Yhteyden eheys: Verify that all electrical and pneumatic connections remain tight and secure.
  • Ammattitaitoinen palvelu: For internal issues or complex repairs, contact a qualified service technician or Johnson Controls support. Do not attempt to disassemble the unit.

7. Vianmääritys

This section provides solutions to common issues that may arise during the operation of the V-9012-1 Solenoid Relay.

OngelmaMahdollinen syyRatkaisu
Device does not respond to electrical input.Ei virtaa, väärä äänenvoimakkuustage, loose wiring, internal fault.Check 12 VDC power supply. Verify wiring connections to Terminals 1 and 2. Ensure correct polarity. If problem persists, contact support.
Pneumatic output is incorrect or inconsistent.Insufficient supply pressure, clogged lines, leaks in pneumatic connections, internal valve issue.Check pneumatic supply pressure. Inspect lines for obstructions or leaks. Ensure correct electrical input for desired pneumatic state.
Laite ylikuumenee.Excessive current, improper ventilation, continuous operation beyond duty cycle.Verify input current does not exceed 50 mA. Ensure adequate airflow around the device. Review application for duty cycle requirements.

8. Tekniset tiedot

Technical specifications for the Johnson Controls V-9012-1 E/P Solenoid Relay:

ParametriArvo
MallinumeroV-9012-1
ToimintoE/P Solenoid Relay
Tulo Voltage12 VDC
Suurin tulovirta50 mA
Pneumatic StatesPress (+12 VDC), Hold (0 VDC), Exhaust (-12 VDC)
ValmistajaJOHNSON CONTROLS
Tuotteen paino6.4 unssia
Päivämäärä ensimmäinen saatavilla5. heinäkuuta 2012

9. Takuu ja tuki

For information regarding product warranty, technical support, or service, please contact Johnson Controls directly through their official website or customer service channels. Keep your purchase receipt and product model number readily available when seeking support.

Aiheeseen liittyvät asiakirjat - V-9012-1

Preview Johnson Controlsin pronssiset häkkiventtiilit: 3/4–2 tuuman tuoteopas
Kattava tekninen opas Johnson Controlsin pronssihäkkiventtiileille (3/4 - 2 tuumaa), jossa kuvataan ominaisuudet, pneumaattiset ja sähköiset toimilaitevaihtoehdot, tekniset tiedot, käyttö, asennus ja korjausosat LVI-sovelluksiin.
Preview Johnson Controlsin EP-8000-sarjan sähköpneumaattiset muuntimet: Tekniset tiedot, asennus ja käyttö
Yksityiskohtainen tekninen tiedote Johnson Controlsin EP-8000-sarjan sähköpneumaattisille muuntimille. Kattaa tuotteen, joka ylittääview, toiminta, mitat, asennus, johdotus, kalibrointi ja tekniset tiedot teollisuuden ohjaussovelluksiin.
Preview VG7000-sarjan pronssisten säätöventtiilien asennusopas
Kattavat asennusohjeet ja tekniset tiedot Johnson Controlsin VG7000-sarjan pronssisäätöventtiileille, jotka on suunniteltu veden ja höyryn säätöön LVI-järjestelmissä. Sisältää venttiilin mitat, materiaalit ja käyttöparametrit.
Preview Johnson Controlsin venttiilien korjausosien luettelo
Kattava luettelo varaosista, mukaan lukien kalvot, jousisarjat, tiivistesarjat, kunnostussarjat ja muut komponentit laajaan valikoimaan Johnson Controlsin pneumaattisia ja sähköisiä venttiilejä.
Preview VP1000 kompaktin säätöventtiilin (aksiaalisen) asennusopas
Johnson Controlsin VP1000 Compact Globe (aksiaalinen) -säätöventtiilin asennusopas, kattaa koot 1/2 tuumasta 1 1/4 tuumaan (DN15-DN32). Sisältää tekniset tiedot, asennusohjeet ja huolto-ohjeet.
Preview Johnson Controlsin CSD-sarjan jaetun ytimen virtakytkimen asennusopas
Asennus- ja tekninen opas Johnson Controlsin CSD-sarjan jaetun ytimen virtakytkimille (CSD-CF0J1-1, CSD-CA1G1-1) releellä. Kattaa sovellukset, johdotuksen, kalibroinnin, vianmäärityksen ja teollisuusvirranvalvonnan tekniset tiedot.