Tekniset tiedot
| Erittely | Yksityiskohdat |
|---|---|
| Tuotteen nimi | Microcomputer Temperature Controller (XH-W3002) |
| Mittausalue | -50°C to 110°C (-50°C to 100°C model variation) |
| Ohjausalue | -50°C to 110°C (-50°C to 100°C model variation) |
| Lämpötilan mittauksen tarkkuus | ±0.2°C |
| Lämpötilan säädön tarkkuus | ±0.1°C |
| Mittaustulo | NTC10K L=1m waterproof probe |
| Input Power Options | 12V / 24V / 220V AC/DC |
| Lähtötehovaihtoehdot | 120W (12V) / 240W (24V) / 1500W (220V) |
| Lähtötyyppi | Suora lähtö |
| Lähtökapasiteetti | Max 10A |
| Asennusreiän etäisyys | 73mm (Hole size: 4mm) |
| Mitat | 60mm × 45mm × 31mm |
Pika-asennus ja käyttö
- Connect the temperature sensor: use the supplied NTC10K waterproof probe (L=1m).
- Provide power using one supported option: 12V/24V/220V AC/DC.
- Set start temperature (P0): press the Asetus button to enter the menu (default to P0), press Asetus again, then use Up/Alas to set the desired start temperature.
- Set stop temperature (P1): in the menu, use Up/Alas to select P1, press Asetus again, then adjust with Up/Alas.
- (Optional) Calibrate temperature (P2): select P2, press Asetus to enter calibration, then set the offset value using Up/Alas.
- (Optional) Set delayed start (P3): select P3 and set the delay time (minutes) using Up/Alas (recommended 3–6 minutes for compressor-based refrigeration; otherwise leave at 0).
Wiring Diagrams & Safety Information
12V / 24V Connection Way
Huomautus: 12V/24V power supplies must use a stable DC power source.
220V Connection Way
Varoitus: This model is designed with direct output power. Exercise extreme caution when connecting the electricity. Ensure the load is connected to the output terminal port before powering up to prevent potential output short circuit ignition or sparks.
Settings Parameter Menu
| Koodi | Kuvaus | Asetusalue | Tehdasasetus |
|---|---|---|---|
| P0 | Käynnistyslämpötila | -50 - 110 °C | 00 °C |
| P1 | Pysäytä lämpötila | -50 - 110 °C | 00 °C |
| P2 | Lämpötilan korjaus | -10 - 10 °C | 0 °C |
| P3 | Delay to start | 0-10 minuuttia | 0 minuuttia |
Parameter Configurations & Functions
P0: Start-up Temperature Setting
Paina Asetus button to enter the internal menu. The display will default to P0. Paina Asetus button once more, then use the Up ja Alas buttons to set your desired start temperature.
Paina Asetus button to enter the internal menu. When
P0 is displayed, use the Up or Alas painikkeita valitaksesi P1. Paina Asetus button again, and adjust the target stop temperature using the Up ja Alas painikkeita.Paina Asetus button to enter the internal menu, then switch to
P2 käyttämällä Up or Alas painikkeet. Paina Asetus button again to calibrate. Use the Up ja Alas buttons to enter the offset value.Calibration Formula: Detected Temperature + Calibration Temperature = Actual Temperature
- If the detected temperature is 0.5°C higher than the actual temperature: Set P2 to -0.5 °C
- If the detected temperature is 1.0°C lower than the actual temperature: Set P2 to 1.0 °C
P3: Delayed Start Setting
Paina Asetus button to enter the internal menu and switch to P3 käyttämällä Up or Alas painikkeet. Paina Asetus button again and set the delay time in minutes using the Up or Alas painikkeita.
Huomautus: This function is typically used for compressor-based refrigeration systems (like refrigerators or freezers) to protect the motor. A delay of 3 to 6 minutes is recommended. If you are not controlling a compressor, leave this set to 0.
Toimintatilat
LämmitystilaSääntö:Start-up Temperature (P0) < Stop Temperature (P1) The system automatically determines it is in heating mode when P0 is configured lower than P1.
Exampskenaario:
Control a water heater to turn off when the temperature reaches 50°C and restart heating when the temperature drops back down to 40°C.
- Verify that the heating rule is met: Start-up (40°C) is less than Stop (50°C).
- Paina Asetus button, enter the menu, select
P0, and adjust the value to 40 °C. - Paina Asetus button, enter the menu, select
P1, and adjust the value to 50 °C.
JäähdytystilaSääntö: Start-up Temperature (pø) > Stop Temperature (Pl). The system automatically determines it is in cooling mode when P0 is configured higher than P1.
Exampskenaario:
Control a cabinet radiator to turn on when temperatures reach 30°C and stop cooling once the temperature drops to 26°C.
- Verify that the cooling rule is met: Start-up (30°C) is greater than Stop (26°C).
- Paina Asetus button, enter the menu, select
P0, and adjust the value to 30 °C. - Paina Asetus button, enter the menu, select
P1, and adjust the value to 26 °C.
Vianetsintä
Common Fault: Incorrect Settings
If you set your temperature values upside down (e.g., configuring heating parameters with P0 > P1), the output indicator light will remain off and the connected load will not work. Check the temperature values in your P0 ja P1 settings if the system is unresponsive.
With the controller powered on, press and hold both the Up ja Alas buttons simultaneously for approximately 3 seconds. Once the digital tube displays
888, The controller will automatically return to real-time temperature detection, indicating a successful factory reset.- Display “LLL”: Indicates a temperature sensor probe failure. Please inspect, repair, or replace the waterproof probe.
- Display “HHH”: Indicates that the ambient temperature has exceeded the controller’s detection range. Relocate the unit to an appropriate environment.