1. Johdanto
The SINOTIMER STVP series automatic over-voltage ja under-voltage protector is designed for three-phase 3*127V/220VAC power systems with a rated working current of 80A. This device provides essential protection for electrical equipment by instantaneously cutting off the power supply when over-voltage, altage, or over-current conditions are detected. Once the circuit voltage returns to normal, the protector automatically restores power, ensuring continuous operation and safeguarding your appliances from damage.
This protector integrates multiple protection functions including over-voltage, altage, over-current, three-phase current (voltage) imbalance, phase sequence (reverse phase), zero-break, and phase-break protection. It also features voltmeter and ammeter functions, and the ability to restore factory settings. The device offers comprehensive features, stable performance, and ease of operation.
Yksityiskohtainen käyttöohje PDF-muodossa on ladattavissa: Käyttöopas (PDF)
2. Tärkeimmät ominaisuudet
- Yli-voltage suojaus
- Alivtage suojaus
- Ylivirtasuojaus
- Automaattinen palautus
- Voitage display (separate ABC phase voltage mittaus)
- Ampere display (separate ABC phase ampere measurement)
- Kolmivaiheinen ampere unbalance protection
- Phase sequence protection (reverse phase protection)
- Zero line break protection
- Vaihevikasuojaus
- Fault inquiry function
- Rotation display of voltage and current for each phase
- Säädettävä yliäänenvoimakkuustage protection value and recovery value
- Säädettävä aliäänenvoimakkuustage protection value and recovery value
- Adjustable over-current protection value and action time
- Adjustable 3-phase ampere unbalance protection value and action time
- Adjustable delay time after power-on
- Säädettävä viankorjausviive
- Factory data reset function
3. Tuotteen tekniset tiedot
| Attribuutti | Arvo |
|---|---|
| Mallinumero | STVP936-1-80A |
| Virtalähde | 3*127V/220VAC 60Hz |
| Rated Voltage | 220V |
| Vaihe | Kolmivaiheinen |
| Maks. Kuormavirta | 1~80A Adjustable (default: 80A) |
| Yli-voltage Suojausalue | 121V-150V-OFF Adjustable (default: 140V) |
| Yli-voltage Recovery Range | 120V-149V (default: 135V) |
| Yli-voltage Action Time | 0.1~10 seconds (default: 0.2s) |
| Alivtage Suojausalue | 118V-80V-OFF Adjustable (default: 90V) |
| Alivtage Recovery Range | 118V-91V (default: 95V) |
| Alivtage Action Time | 0.1~10 seconds (default: 0.2s) |
| 3-Phase Volt Unbalance Protection | 10%~50%~OFF (default: 20%) |
| 3-Phase Volt Unbalance Action Time | 0.1~10 seconds (default: 1s) |
| Delay Time After Power-on | 2~255 seconds (default: 2s) |
| Fault Recovery Delay Time | 2~600 seconds (default: 60s) |
| Näytä malli | LCD |
| Mitat | 71.5mm (W) * 95.2mm (H) * 65.7mm (D) |
| Asennus | 35 mm DIN-kisko |
| Sertifiointi | CE, RoHS |
4. Turvallisuustiedot
- Asennuksen ja huollon saa suorittaa vain pätevä sähköasentaja.
- Varmista, että virtalähde on irrotettu ennen asennus- tai johdotustöitä.
- The device does not provide overload or short-circuit protection. It must be used in conjunction with appropriate external circuit breakers (e.g., C45, C65 mini circuit breakers) for comprehensive protection.
- Varmista, että kaikki johdotusliitännät ovat tukevasti kiinni ja oikein ennen virran kytkemistä.
- Do not operate the device in wet or hazardous environments.
5. Asennus
5.1 Fyysiset mitat

5.2 Asennus
The protector is designed for 35mm DIN rail installation. Snap the device onto the DIN rail securely.

5.3 Kytkentäkaavio
Connect the input and output terminals as shown in the diagram below. Ensure correct phase (L1, L2, L3) and neutral (N) connections. The input terminals are located at the top, and output terminals at the bottom.


6. Asennus ja määritykset
Siirry asetustilaan pitämällä -painiketta painettuna SARJA button for 3 seconds. Then, continuously press SARJA to cycle through the parameters. Use the ▲ ja ▼ buttons to adjust the values. When "ENd" appears, press SARJA again to save the data and exit the setting mode.
If no operation is performed within 10 seconds after pressing SARJA, the device will automatically exit the setting mode, and any unsaved changes will be lost.
6.1 Parameter Settings Table
| Vaihe | Sisältö | LCD-näyttö | Description / Range (Default) |
|---|---|---|---|
| 1 | Yli-voltage suoja -arvo | Uvo 280V | 221V-300V-OFF (280V) |
| 2 | Yli-voltage palautusarvo | Uvor 250V | 220V-299V (250V) |
| 3 | Yli-voltagsuojauksen toiminta-aika | 0.2S | 0.1-10s (0.2s) |
| 4 | Alivtage suoja -arvo | Uve 160V | 219V-150V-OFF (160V) |
| 5 | Alivtage palautusarvo | Uver 180V | 151V-220V (180V) |
| 6 | Alivtagsuojauksen toiminta-aika | 0.2S | 0.1-10s (0.2s) |
| 7 | Ylivirtasuojausarvo | >In 80A | 1-80A (80A) |
| 8 | Ylivirtasuojauksen toiminta-aika | 5S | 1-512s (5s) |
| 9 | 3 vaihetta amp unbalance protection value | >In % | 5%-90%-OFF (25%). Not active if current < 2A. |
| 10 | 3 vaihetta amp unbalance protection action time | 1.0 S | 0.1-10s (1s) |
| 11 | Vaihejärjestyksen suojaus | ON ABC | ON or OFF (ON) |
| 12 | Käynnistysviiveaika | 2 S | 2-255s (2s) |
| 13 | Fault recovery delay time | 60 S | 2-512s (60s) |
| 14 | Fault inquiry code | E0 | Press ▲ to view last 5 fault records (E1-E5). >U for overvoltage, <U for undervoltage. |
| 15 | Loppuu | LOPPU | Press SET to save and exit. |
6.2 Tehdasasetusten palautus
Palauta laitteen tehdasasetukset pitämällä painiketta painettuna ▲ ja ▼ painikkeita samanaikaisesti 3 sekunnin ajan.
7. Käyttö
Once installed and configured, the device will continuously monitor the three-phase power supply. The LCD screen will automatically rotate to display the real-time voltage ja virta kullekin vaiheelle (L1, L2, L3).
Ylivolyymin tapauksessatage, altage, or over-current event, the protector will automatically trip and cut off the power supply to protect connected equipment. After the fault condition clears and the recovery delay time has passed, the device will automatically restore power.
8. Vianmääritys
8.1 Vikailmoitus
If a fault occurs, the device will display an error code (E0). You can press the ▲ button to query the last 5 fault records (E1-E5). The display will indicate:
- ">U" for overvoltage tapahtumia.
- "<U" for undervoltage tapahtumia.
8.2 Phase Sequence Error
If the LCD displays "ABC" character, it indicates a phase sequence error. To correct this, arbitrarily reverse any two of the three phase lines (L1, L2, L3) at the input.
9. Huolto
- Pidä laite puhtaana ja vapaana pölystä ja kosteudesta.
- Tarkista säännöllisesti johtojen liitosten kireys ja kulumisen tai vaurioiden merkit.
- Do not attempt to repair the device yourself. Refer to qualified personnel for service.
10. Takuu ja tuki
For technical support, inquiries, or warranty claims, please contact the distributor:
Jakelija: XNY INTERNATIONAL LIMITED
Osoite: Room 20A, Kiu Fu Commercial Building, 300 Lockhart Road, Wanchai, Hong Kong.
Puh: 0086 57761733853
Faksi: 0086 577 89736991
WhatsApp: 0086 1565857 3377
Wechat: sinotimer
Skype: sinotimer
Web: www.sinotimer.com
Sähköposti: info@sinotimer.com