1. Johdanto

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Wiltec Pool Pump, model 65829. This pump is designed for circulating and filtering water in pools ranging from 74 to 110 cubic meters, offering a high flow rate of 18,600 liters per hour and a maximum head of 13 meters. It is compatible with sand filter systems and features an integrated pre-filter for enhanced protection.

Wiltec Pool Pump 18600 L/h installed next to a swimming pool

Kuva 1: Wiltec Pool Pump 18600 L/h in a typical pool setup. This image shows the pump connected to a pool system, highlighting its compact design and connection points.

2. Turvallisuustiedot

Read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.

  • Irrota pumppu aina virtalähteestä ennen huolto- tai puhdistustöitä.
  • Ensure the electrical installation complies with local regulations and is protected by a Residual Current Device (RCD) with a tripping current not exceeding 30 mA.
  • Älä käytä pumppua, jos virtajohto tai pistoke on vaurioitunut.
  • The pump must be installed on a stable, level surface, protected from direct sunlight and adverse weather conditions.
  • Ensure adequate ventilation around the pump motor to prevent overheating.
  • This pump is designed for fresh water only, with a liquid temperature range of 0-35°C. Do not use with corrosive, flammable, or explosive liquids.

Tarkemmat turvallisuusohjeet löytyvät virallisesta turvallisuustietojen PDF-dokumentista: Turvallisuustiedot (PDF)

3. Tuotteen osat ja mitat

The Wiltec Pool Pump consists of a robust motor, a pump housing with an integrated pre-filter, and inlet/outlet connections. Understanding the dimensions is crucial for proper installation and space planning.

Technical drawing showing the dimensions of the Wiltec Pool Pump

Kuva 2: Product Dimensions. This diagram illustrates the pump's overall length (580 mm), width (242 mm), and height (367 mm), along with specific measurements for connections and components.

Keskeisiä komponentteja ovat:

  • Esisuodattimen kori: Located at the inlet, designed to capture debris larger than 3.9 mm.
  • Moottori: 750W copper-wound motor with thermal overload protection.
  • Pumpun kotelo: Kestävä muovirakenne.
  • Tulo-/poistoaukko: Standard connections for pool hoses.

4. Asennus ja asennus

Proper installation is vital for the pump's performance and longevity. It is recommended that installation be performed by a qualified technician.

  1. Sijoitus: Position the pump on a firm, level surface as close to the pool as possible to minimize suction lift. Ensure it is below the water level if possible for self-priming.
  2. Asennus: Secure the pump to the surface using appropriate fasteners to prevent vibration and movement.
  3. Putkiliitännät: Connect the pump's inlet to the pool skimmer/main drain line and the outlet to the sand filter and return lines. Ensure all connections are watertight using thread sealant tape or appropriate gaskets.
  4. Sähköliitäntä: Connect the pump to a dedicated, properly grounded electrical circuit protected by an RCD. Verify that the power supply voltage matches the pump's requirements (230V, 50Hz).
  5. Pohjustus: Before first use, fill the pre-filter housing with water to ensure the pump is primed. This prevents dry running and potential damage.

5. Käyttöohjeet

Once installed and primed, the pump is ready for operation.

  1. Pumpun käynnistäminen: Ensure all valves are open and the pre-filter is full of water. Connect the pump to the power supply. The pump will start circulating water.
  2. Suorituskyvyn seuranta: Observe the water flow and pressure gauge (if installed on your filter system) to ensure optimal operation. The pump is designed for a maximum flow rate of 18,600 L/h and a maximum head of 13 meters.
  3. Lämpötila-alue: The pump is designed to operate with liquid temperatures between 0°C and 35°C. Operating outside this range may damage the pump.
  4. Pumpun pysäyttäminen: Disconnect the pump from the power supply. Close any necessary valves to prevent water backflow.
Diagram showing optimal flow rate and head for the Wiltec Pool Pump

Kuva 3: Optimal Performance. This image highlights the pump's maximum head of 13 meters and maximum flow rate of 18,600 L/h, along with the recommended liquid temperature range of 0-35°C.

6. Huolto

Säännöllinen huolto varmistaa uima-allaspumppusi pitkän käyttöiän ja tehokkaan toiminnan.

  • Esisuodattimen puhdistus: The integrated pre-filter collects debris such as leaves, twigs, gravel, and hair. Regularly inspect and clean the pre-filter basket to maintain optimal flow and prevent pump strain. To clean, disconnect power, open the pre-filter lid, remove the basket, empty debris, and rinse thoroughly. Reassemble, ensuring the O-ring is properly seated and the lid is securely tightened.
  • Image showing the pre-filter of the Wiltec Pool Pump collecting debris

    Kuva 4: Pre-filter Function. This image demonstrates how the pump's pre-filter effectively captures various types of debris, such as leaves, twigs, gravel, and hair, protecting the pump's internal components.

  • Moottorin tarkastus: Periodically check the motor for any unusual noises or excessive heat. The copper-wound motor is designed for stable operation and includes thermal overload protection.
  • Saketti view of the Wiltec Pool Pump motor showing copper windings

    Kuva 5: Robust Motor Design. This image provides a view of the pump's copper-wound motor, emphasizing its stable operation and built-in protection against overheating and overload.

  • Yleinen puhdistus: Keep the exterior of the pump clean and free from dirt and debris.
  • Talvistaminen: In regions with freezing temperatures, drain the pump completely and store it in a dry, frost-free location during the off-season to prevent damage.

7. Vianmääritys

Jos pumpussasi on ongelmia, katso seuraavat yleiset ongelmat ja ratkaisut:

OngelmaMahdollinen syyRatkaisu
Pumppu ei käynnistyNo power; tripped circuit breaker; motor overload protection activatedCheck power supply and connections; reset circuit breaker; allow motor to cool down if overheated.
Alhainen veden virtausClogged pre-filter basket; air leak in suction line; low water level in pool; clogged impellerClean pre-filter basket; check all suction line connections for leaks; ensure adequate pool water level; inspect impeller for blockages.
Pumppu käy, mutta vesi ei virtaaPump not primed; air lock; closed valve in suction linePrime the pump by filling the pre-filter with water; check for and release air locks; ensure all valves are open.
Epätavallinen melu tai tärinäAir in system; debris in impeller; loose mountingCheck for air leaks and prime pump; clean impeller; tighten mounting bolts.

If problems persist after attempting these solutions, contact a qualified service technician or Wiltec customer support.

8. Tekniset tiedot

ErittelyArvo
ValmistajaWiltec
Mallinumero65829
Virtausnopeus (maks.)18,600 l/h
Wattage750 W
Max pää13 metriä
Suositeltu altaan tilavuus74-110 m³
Tuotteen mitat (P x L x K)58 x 24.7 x 36.7 cm
Tuotteen paino10.25 kg
MateriaaliMuovi
VäriSininen, Musta
Tehotyyppicorded
Nesteen lämpötila -alue0-35 °C

9. Takuu ja tuki

Jos tarvitset takuutietoja, teknistä tukea tai huoltoa, ota yhteyttä jälleenmyyjään tai suoraan valmistajaan. Säilytä ostokuitti ostotodistuksena.

A Certificate of Conformity is available for this product: Certificate of Conformity (PDF)

© 2026 Wiltec. Kaikki oikeudet pidätetään.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.