DEWIN DEWINycptern4i2

DEWIN Pressure Sprayer Instruction Manual

Model: DEWINycptern4i2

1. Johdanto

This manual provides instructions for the DEWIN Handheld Pressure Sprayer, designed for various garden and household spraying tasks. It features a dual-mode nozzle for mist or stream applications and is compatible with standard G3/4 threaded bottles of 1.25L capacity or larger.

DEWIN Pressure Sprayer main unit

Kuva 1: Päättynytview of the DEWIN handheld pressure sprayer, showing its blue handle, brass rod, and dual nozzle head.

2. Turvallisuustiedot

  • Lue kaikki ohjeet ennen käyttöä.
  • Wear appropriate personal protective equipment, such as gloves and eye protection, when handling chemicals.
  • Älä suihkuta syttyviä nesteitä tai syövyttäviä aineita.
  • Pidä ruisku poissa lasten ja lemmikkien ulottuvilta.
  • Ensure proper ventilation when spraying indoors or in enclosed spaces.
  • Always flush the sprayer with clean water after each use, especially when using chemicals.

3. Pakkauksen sisältö

Varmista, että kaikki osat ovat mukana:

  • 1 x DEWIN Pressure Sprayer Unit (with integrated pump and dual nozzle)
  • Replacement Washers (may be included for maintenance)

4. Asennus

  1. Valmista pullo: Select a clean plastic bottle with a G3/4 female thread and a capacity of 1.25 liters or more. Fill the bottle with the desired liquid (water, fertilizer, pesticide, etc.). Do not overfill.
  2. Attach the Sprayer: Carefully screw the sprayer unit onto the bottle. Ensure the fixing nut is tightened securely to create a good airtight seal. This seal is crucial for building and maintaining air pressure.
Close-up of DEWIN Pressure Sprayer nozzle and bottle connector

Kuva 2: Yksityiskohtainen view of the sprayer's brass dual nozzles and the blue bottle connector with a G3/4 female thread.

5. Käyttöohjeet

  1. Rakennepaine: Hold the sprayer with one hand and use the other hand to operate the pump handle. Pump the handle repeatedly to build air pressure inside the bottle. The sprayer is designed to spray on both the push and pull strokes of the pump.
  2. Valitse ruiskutustila: The sprayer features a double nozzle design that can be rotated and adjusted.
    • a water column (stream), rotate the nozzles to a more focused position. This mode is suitable for targeted spraying.
    • a mist (fogging), rotate the nozzles to a wider, more dispersed position. This mode is ideal for broad coverage or delicate plants.
  3. Aloita ruiskutus: Once sufficient pressure is built and the desired spray mode is set, direct the nozzle towards the target area and continue pumping to maintain pressure and spray.
DEWIN Pressure Sprayer in water stream mode

Figure 3: Sprayer demonstrating water jet mode.

DEWIN Pressure Sprayer in mist mode

Figure 4: Sprayer demonstrating fine mist (fogging) mode.

DEWIN Pressure Sprayer double nozzle design

Figure 5: The double nozzle design allows for rotation and adjustment between spray patterns.

DEWIN Pressure Sprayer used for various garden tasks

Kuva 6: Esimamples of the sprayer in use for different garden applications.

6. Huolto

  • Puhdistus: After each use, especially when spraying chemicals, empty any remaining liquid and flush the sprayer thoroughly with clean water. Pump clean water through the nozzle to prevent clogging.
  • Tarkista tiivisteet: Periodically inspect the fixing nut and any internal washers for wear or damage. Replace worn washers to maintain an airtight seal and prevent leaks.
  • Varastointi: Store the sprayer in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure it is clean and dry before storage.

7. Vianmääritys

  • Leaking around the bottle connection:
    Ensure the bottle is securely screwed onto the sprayer and the fixing nut is tight. Check the washer inside the connector for proper seating or damage. Replace if necessary.
  • No spray or weak spray:
    Verify that sufficient air pressure has been built by pumping the handle multiple times. Check the nozzle for clogs; clean by rotating or gently disassembling if possible. Ensure the bottle contains enough liquid.
  • Difficulty attaching to a bottle:
    Confirm that the bottle has a G3/4 female thread and a capacity of 1.25L or more. Some bottles may have slightly different thread patterns; ensure a compatible fit.
  • Pump mechanism feels stiff or bent:
    Inspect the pump rod for any physical damage or bending. If bent, the pumping action may be compromised.

8. Tekniset tiedot

OminaisuusErittely
MerkkiDEWIN
MallinumeroDEWINycptern4i2
MateriaaliKupari, Muovi
Tuotteen mitat (P x L x K)14.17 x 2.76 x 0.79 tuumaa (noin 36 x 7 x 2 cm)
Stretched Length (Approx.)56 cm / 22.0 tuumaa
Main Body Length (Approx.)38.5 cm / 15.2 tuumaa
Tuotteen paino0.14 kg
TuloliitäntätyyppiKierteitetty
LähtöliitäntätyyppiG3/4
Porttien määrä2
Venttiilin tyyppiOn/Off venttiili
DEWIN Pressure Sprayer dimensions diagram

Figure 7: Diagram illustrating key dimensions of the sprayer.

9. Takuu ja tuki

Jos tarvitset takuutietoja tai teknistä tukea, ota yhteyttä jälleenmyyjään tai valmistajan viralliseen edustajaan. websivusto. Säilytä ostokuitti ostotodistuksena.

© 2026 DEWIN. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.