1. Johdanto
The UNI-T UT60S is a smart, true RMS digital multimeter designed for accurate and reliable electrical measurements. Featuring 9999 counts, this device can measure AC/DC voltage, AC/DC current, resistance, diode, capacitance, temperature, and frequency. Its fully automatic anti-burn intelligent design helps prevent operational errors and device damage, making it suitable for both professional technicians and everyday users.

Kuva 1: Etuosa view of the UNI-T UT60S Digital Multimeter.
2. Turvallisuustiedot
Always adhere to safety precautions when using the multimeter. Failure to do so may result in electric shock, injury, or damage to the meter or equipment under test.
- Lue käsikirja: Before use, thoroughly read and understand all instructions and safety warnings in this manual.
- Rated Voltage: Älä käytä enempää kuin nimellistilavuustage, as marked on the meter, between terminals or between any terminal and earth ground. The UT60S is capable of withstanding a maximum overvoltage impulse of 1000V.
- Tarkista ennen käyttöä: Before each use, inspect the meter, test leads, and accessories for any damage. Do not use if damaged.
- Proper Terminals: Ensure test leads are connected to the correct input terminals for the measurement function selected.
- Circuit De-energization: Always de-energize the circuit and discharge all high-voltagIrrota kondensaattorit ennen resistanssi-, jatkuvuus-, diodi- tai kapasitanssimittausten suorittamista.
- Live Circuit Work: When working on live circuits, work alone as little as possible, and ensure another person is present to provide assistance if needed.
- Ylivirtasuoja: The meter features overcurrent alarms and protection functions. Do not exceed the maximum current ratings for the input terminals.
- Ympäristöolosuhteet: Use the meter only as specified in this manual. Do not use the meter in explosive gas, vapor, or dusty environments.
- Henkilökohtaiset suojavarusteet: Käytä aina asianmukaisia henkilönsuojaimia, kuten suojalaseja ja eristettyjä käsineitä, työskennellessäsi sähköpiirien kanssa.
3. Tuotteen ominaisuudet
The UNI-T UT60S Digital Multimeter offers a range of features for versatile and safe electrical testing:
- 9999 Counts Näyttö: Provides high-resolution measurements for precision.
- Todellinen RMS-mittaus: Varmistaa tarkat lukemat ei-sinimuotoisille aaltomuodoille.
- Fully Automatic Anti-Burn Design: Intelligent protection against operational errors and potential device damage.
- Wide Measurement Capabilities: Mitat AC/DC voltage (up to 1000V), AC/DC current, resistance, diode, capacitance, temperature, and frequency.
- Large LCD Screen with Dual Display: Allows simultaneous display of AC voltage and frequency, enhancing readability.
- Full Button Design: Offers intuitive control and automatic recognition of current input jacks.
- Fast ADC (Analog to Digital Converter): Provides rapid measurement updates (3 times/second).
- Misoperation Protection: Capable of withstanding a maximum overvoltage impulse of 1000V, with overvoltage and overcurrent alarms.
- NCV (Non-Contact Voltage) Toiminto: Havaitsee AC voltage without physical contact, featuring audible and visual alarms for safety.
- Automaattinen virransäästö: Low power consumption (7mA during operation, 5uA in sleep state) and automatic backlight display in dark environments, extending battery life. Automatic shut-down feature.

Figure 2: The UT60S display with 9999 counts for precise readings.
4. Mitä laatikossa on
Kun avaat pakkauksen, sinun pitäisi löytää seuraavat kohteet:
- UNI-T UT60S digitaalinen yleismittari
- Thermocouple (for temperature measurements)
- Multimeter Test Leads (red and black)
- 1.5V AAA Batteries (pre-installed or included separately)

Figure 3: Contents of the UNI-T UT60S package, including the multimeter, test leads, and thermocouple.
5. Asennus
5.1. Akun asennus
The UT60S typically uses 1.5V AAA batteries. To install or replace batteries:
- Varmista, että yleismittari on sammutettu ja mittausjohdot on irrotettu.
- Paikanna paristolokero mittarin takaa.
- Avaa paristolokeron kansi ruuvimeisselillä.
- Aseta AAA-paristot paikoilleen ja huomioi oikea napaisuus (+ ja -).
- Aseta paristolokeron kansi takaisin paikalleen ja kiinnitä se ruuvilla.

Kuva 4: Takaosa view of the UT60S, indicating the battery compartment location.
5.2. Testijohtojen liittäminen
Connect the test leads to the appropriate input terminals:
- The black test lead (common) should always be connected to the COM terminaali.
- Voltage, resistance, capacitance, frequency, diode, and continuity measurements, connect the red test lead to the VΩHzCAP terminaali.
- For current measurements (mA/A), connect the red test lead to the mA/A terminaali.
- Mikroilleampere current measurements (μA), connect the red test lead to the μA terminaali.

Figure 5: Input terminals of the UT60S for connecting test leads.
6. Käyttöohjeet
The UT60S features a full button design for selecting measurement functions. The meter's intelligent anti-burn design automatically recognizes the input jack and selected function.
6.1. Virta päälle/pois
Paina POWER button to turn the meter on or off. The meter will automatically shut down after a period of inactivity to save battery life.
6.2. Auto-tila
In Auto mode, the meter automatically identifies the measurement type (voltage, resistance, continuity) and selects the appropriate range. This simplifies operation for general troubleshooting.
6.3. AC/DC-volyymin mittaaminentage
Mittaa voltage:
- Liitä musta mittausjohto COM terminaali ja punainen mittausjohto VΩHzCAP terminaali.
- Paina V~ / Hz button to select AC voltage measurement, or the V= / NCV button for DC voltage. The meter may automatically select the correct mode in Auto range.
- Kytke mittausjohdot mitattavaan piiriin tai komponenttiin.
- Lue voltage-arvo näytössä. Verkkovirran äänenvoimakkuuden osaltatage, the frequency may also be displayed simultaneously.

Kuva 6: Vaihtovirtavirran mittaaminentage and frequency with the UT60S.
6.4. AC/DC-virran mittaaminen
Virran mittaaminen:
- TÄRKEÄÄ: To measure current, the meter must be connected in series with the circuit. Always turn off power to the circuit before connecting the meter.
- Liitä musta mittausjohto COM terminaali.
- For current up to 10A, connect the red test lead to the mA/A terminal. For microampere current, connect to the μA terminaali.
- Paina ACA/DCA button to select AC or DC current measurement.
- Break the circuit and connect the test leads in series with the load.
- Kytke virta virtapiiriin ja lue näytöltä virta-arvo.
6.5. Measuring Resistance, Diode, and Continuity
Resistanssin, diodin tai jatkuvuuden mittaaminen:
- Ensure the circuit is de-energized and capacitors are discharged.
- Liitä musta mittausjohto COM terminaali ja punainen mittausjohto VΩHzCAP terminaali.
- Paina Ω→+ button to cycle through resistance, diode, and continuity functions.
- Kytke mittausanturit komponentin poikki.
- Read the measurement. For continuity, an audible buzzer will sound if continuity is detected.
6.6. Kapasitanssin mittaaminen
Kapasitanssin mittaaminen:
- Varmista, että kondensaattori on täysin purkautunut ennen testausta.
- Liitä musta mittausjohto COM terminaali ja punainen mittausjohto VΩHzCAP terminaali.
- Paina mV~°C°F button to select temperature measurement.
- Kytke mittausjohdot kondensaattorin liittimiin.
- Lue kapasitanssin arvo näytöstä.

Figure 7: The UT60S performing a capacitance measurement.
6.7. Lämpötilan mittaus
Lämpötilan mittaaminen:
- Connect the thermocouple to the appropriate input terminals (usually the VΩHzCAP ja COM terminals, or dedicated temperature inputs if available).
- Paina mV~°C°F button to select temperature measurement.
- Aseta termoelementtianturi kohtaan, josta lämpötila on mitattava.
- Read the temperature value on the display in Celsius or Fahrenheit.
6.8. NCV (Non-Contact Voltage) Toiminto
The NCV function allows detection of AC voltage ilman suoraa kosketusta johtimiin.
- Paina V= / NCV button to activate the NCV function.
- Move the top of the meter close to the conductor or outlet.
- The meter will provide an audible alarm and visual indication (flashing light) if AC voltage is detected. The intensity of the alarm and light may vary with voltage-voima.

Kuva 8: NCV-toiminnon käyttö jännitteellisen vaihtovirtajännitteen havaitsemiseentage.
6.9. Tietojen säilytys
Paina PIDÄ -painiketta pysäyttääksesi nykyisen lukeman näytössä. Paina sitä uudelleen vapauttaaksesi pitotoiminnon.
6.10. Mittausalueen valinta
While the meter typically operates in Auto range, you can manually select a range by pressing the ALUE button. This can be useful for specific applications or to speed up measurements in stable conditions. Press and hold the ALUE button to return to Auto range.
6.11. USB Communication (if applicable)
The UT60S series may support USB communication for data logging and analysis on a computer. If your model includes this feature, connect the meter to your computer using the provided USB cable and install the UNI-T software. Refer to the software manual for detailed instructions.
Video 1: Demonstration of features like NCV, LoZ, and USB communication on a UNI-T UT161 series multimeter. The UT60S shares similar functionalities.
7. Huolto
7.1. Puhdistus
Pyyhi mittarin kotelo mainoksellaamp liinalla ja miedolla pesuaineella. Älä käytä hankaavia aineita tai liuottimia. Varmista, että mittari on täysin kuiva ennen käyttöä.
7.2. Pariston vaihto
Vaihda paristot, kun näytössä näkyy heikon pariston ilmaisin. Katso paristojen asennusohjeet kohdasta 5.1.
7.3. Sulakkeen vaihto
If the current measurement function stops working, the fuse may need replacement. Refer to the full user manual for specific fuse ratings and replacement procedures. Always use fuses with the specified voltage ja nykyiset arvosanat.
8. Vianmääritys
If you encounter issues with your UNI-T UT60S, try the following basic troubleshooting steps:
- Ei näyttöä/virta päällä: Tarkista paristojen asennus ja varmista, että paristot eivät ole tyhjentyneet. Vaihda tarvittaessa.
- Väärät lukemat: Verify that the test leads are correctly connected to the appropriate terminals for the selected function. Ensure the function dial is set correctly. Check for damaged test leads.
- Virran mittaus ei toimi: Check the fuse. If blown, replace it with a fuse of the correct rating. Ensure the meter is connected in series with the circuit.
- "OL" tai ylikuormituksen ilmaisin: This indicates that the measured value is outside the selected range or the maximum capability of the meter. Try selecting a higher range (if in manual range mode) or ensure the component is within the meter's specifications.
- NCV ei havaitse: Ensure the NCV function is activated and the meter is brought close enough to the AC voltage lähde.
For more complex issues, refer to the detailed troubleshooting section in the complete user manual or contact UNI-T customer support.
9. Tekniset tiedot
Key specifications for the UNI-T UT60S Digital Multimeter:
| Ominaisuus | Erittely |
|---|---|
| Näytön määrä | 9999 |
| Todellinen RMS | Kyllä |
| AC/DC Voitage | 1000V asti |
| AC / DC-virta | Up to 10A (mA/A terminals), Up to 1000μA (μA terminal) |
| Resistanssi | 0.1 Ω - 40 MΩ |
| Kapasitanssi | 1nF - 4000μF |
| Lämpötila | Yes (with thermocouple) |
| Taajuus | Kyllä |
| Dioditesti | Kyllä |
| Jatkuvuustesti | Kyllä |
| NCV (Non-Contact Voltage) | Kyllä |
| Virtalähde | Battery Powered (1.5V AAA batteries) |
| Tuotteen paino | 370 grammaa |
| Turvallisuuden noudattaminen | UL 61010-1, IEC 61010-2-030, CAT III 1000V, CAT II 600V |
10. Takuu ja tuki
UNI-T provides customer support for their products. If you encounter any problems during use, please contact UNI-T customer service directly via email. They offer 7/24 1-to-1 user support to address your concerns promptly.