LARIAU TS58

LARIAU TS58 Digital Insulation Resistance Tester

Käyttöopas

1. Johdanto

The LARIAU TS58 is a digital insulation resistance tester designed for measuring insulation resistance in various electrical equipment and insulating materials. This includes transformers, motors, cables, switches, and other electrical appliances. It is suitable for maintenance, repair, and testing applications.

This instrument features automatic voltage release, high stability, and reliability. It offers a maximum display count of 2000, 100 groups of data storage, and an insulation resistance measurement range of 0.1 MΩ to 10 GΩ. It also includes AC/DC voltage measurement capabilities and advanced DAR (Dielectric Absorption Ratio) and PI (Polarization Index) measurements for more accurate insulation assessment.

LARIAU TS58 Digital Insulation Resistance Tester front view

Kuva 1: Etuosa view of the LARIAU TS58 Digital Insulation Resistance Tester.

2. Turvallisuustiedot

Please read this manual carefully before using the instrument. Adhere to all safety warnings and operating instructions to prevent electric shock, injury, or damage to the instrument.

  • Varmista aina ennen käyttöä, että laite on hyvässä toimintakunnossa.
  • Observe the high voltage indication on the display, which reminds you of safe operation during measurements.
  • Do not operate the instrument in wet environments or with wet hands.
  • Replace batteries promptly when the low battery indication appears to ensure accurate readings and safe operation.
  • Älä yritä mitata voltages or resistances beyond the specified ranges.
  • Ensure proper connection of test leads before initiating any measurement.

3. Tuote ohiview

The TS58 features a clear LCD backlit screen for easy reading, a robust dustproof and moisture-proof shell, a foldable bracket for convenient positioning, and comes with a zipper carry bag for portability.

Lähikuva views of the TS58 LCD screen, dustproof shell, foldable bracket, and zipper carry bag.

Figure 2: Key features of the TS58, including the LCD screen, protective casing, and accessories.

3.1 Ohjauslaitteet ja näyttö

The device includes a large digital LCD display, function buttons for selecting measurement modes, adjusting output voltage, and initiating tests. It also has input terminals for test leads.

LARIAU TS58 Digital Insulation Resistance Tester highlighting key features like output voltage, measuring ranges, DAR/PI, LCD, data hold, and data storage.

Kuva 3: Päättynytview of the TS58's main functions and display elements.

4. Asennus

4.1 Akun asennus

The TS58 is powered by 8 x 1.5V AA/LR6 batteries (not supplied). To install or replace batteries:

  1. Paikanna paristolokero laitteen takana.
  2. Avaa paristolokeron kansi.
  3. Insert 8 AA/LR6 batteries, ensuring correct polarity (+/-).
  4. Sulje paristolokeron kansi kunnolla.

A low battery indication will appear on the display when batteries need replacement.

5. Käyttöohjeet

The TS58 is designed for measuring insulation resistance and AC/DC voltage. Always ensure the test leads are securely connected to the instrument and the circuit under test.

LARIAU TS58 Digital Insulation Resistance Tester with test leads connected, in an electrical testing scenario.

Figure 4: The TS58 tester with test leads, ready for use.

5.1 Eristysvastuksen mittaus

  1. Connect the test leads to the appropriate terminals on the TS58 and to the equipment under test.
  2. Käynnistä laite.
  3. Use the 'SELECT' button to choose the insulation resistance measurement mode.
  4. Säädä lähtöjännitetage (50V/100V/250V/500V/1000V) using the up/down buttons as required for your test.
  5. Press the 'TEST' button to initiate the measurement. The high voltage merkkivalo syttyy.
  6. Read the insulation resistance value on the LCD screen.
  7. After the test, the instrument automatically discharges the circuit.

5.2 AC/DC Voitage Mittaus

  1. Connect the test leads to the appropriate terminals on the TS58 and to the voltage lähde.
  2. Käynnistä laite.
  3. Use the 'SELECT' button to choose the AC or DC voltage mittaustila.
  4. Lue voltage value on the LCD screen. The measurement range is 10V-600V.

5.3 DAR and PI Index Measurement

The DAR (Dielectric Absorption Ratio) and PI (Polarization Index) measurements help assess the quality and aging status of insulation, mitigating the effects of temperature, humidity, and interference currents.

  1. Perform an insulation resistance test as described in section 5.1.
  2. Press the 'PI/DAR' button. The instrument will automatically compute and display the DAR and PI values.
  3. Refer to industry standards for interpreting DAR and PI values to evaluate insulation condition.

5.4 Tietojen tallennus ja haku

The TS58 can store up to 100 groups of measurement data.

  • To save data: After a measurement, press the 'HOLD*' button to hold the current reading, then press 'MEM READ' to save it. (Note: The exact sequence might vary; refer to the full manual for precise steps if available).
  • To recall data: Press the 'MEM READ' button and use the up/down arrows to navigate through stored data groups.
LARIAU TS58 Digital Insulation Resistance Tester being used in various electrical testing applications, including wiring, circuit boards, and motor testing.

Figure 5: The TS58 in practical application scenarios.

6. Huolto

6.1 Puhdistus

Pyyhi laitteen ulkopinta pehmeällä,amp liinalla. Älä käytä hankaavia puhdistusaineita tai liuottimia. Varmista, ettei laitteeseen pääse kosteutta.

6.2 Varastointi

When not in use for extended periods, remove the batteries to prevent leakage. Store the instrument in its zipper carry bag in a dry environment, away from direct sunlight and extreme temperatures. The recommended storage environment is -10~50℃, <75%RH.

7. Vianmääritys

  • Laite ei käynnisty: Tarkista paristojen asennus ja varmista, että paristot eivät ole tyhjentyneet. Vaihda tarvittaessa.
  • Epätarkat lukemat:
    • Varmista, että mittausjohdot on kytketty oikein ja etteivät ne ole vaurioituneet.
    • Verify the correct measurement mode and output voltage are selected.
    • Consider environmental factors like temperature and humidity, especially for insulation resistance measurements.
  • Korkea voltage warning persists after test: The instrument has an automatic voltage release function. If the warning persists, ensure the circuit under test is fully discharged before handling.

8. Tekniset tiedot

The following table details the technical specifications of the LARIAU TS58 Digital Insulation Resistance Tester.

Table of specifications for the LARIAU TS58, including dimensions, color, material, screen type, maximum count, output voltage, resistance range, AC/DC voltage range, AC frequency, data storage, short-circuit current, power supply, work environment, and storage environment.

Figure 6: Detailed technical parameters of the TS58.

LARIAU TS58 Technical Specifications
ParametriArvo
VäriPunainen + harmaa
MateriaaliABS + silikoni
NäyttöLCD-taustavalaistu näyttö
Enimmäismäärä2000
Lähtö Voltage50V/100V/250V/500V/1000V
Resistance Measuring Range0.1 MΩ ~ 10 GΩ
AC/DC Voitage Mittausalue10 V - 600 V
AC Voitage Taajuus40-70 Hz
Tietojen tallennus100 ryhmää
Oikosulkuvirta<1.8 mA
Virtalähde8 * 1.5 V AA/LR6 (not supplied)
Työympäristö0 ~35℃, <75%RH, <2000m
Varastointiympäristö-10–50 ℃, <75 % suhteellinen kosteus
Tuotteen koko180 * 140 * 70 mm / 7.09 * 5.51 * 2.76 tuumaa
Tuotteen paino (ilman akkua)623 g / 1.37 lb

9. Takuu ja tuki

Tiedot tuotteen takuusta ja asiakastuesta annetaan yleensä tuotteen pakkauksessa tai valmistajan virallisessa etiketissä. website. Please refer to those resources for details on warranty coverage, technical assistance, and service inquiries.

For further assistance, please contact LARIAU customer support through their official channels.

© 2023 LARIAU. All rights reserved.

Tämä käyttöohje on tarkoitettu vain tiedoksi. Tekniset tiedot voivat muuttua ilman erillistä ilmoitusta.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.