1. Johdanto
This manual provides essential instructions for the installation, operation, and maintenance of your FSP iFP600 Uninterruptible Power Supply (UPS). Please read this manual thoroughly before installing or operating the unit to ensure proper function and safety. The FSP iFP600 is designed to provide reliable power backup and surge protection for your electronic devices.

Kuva 1.1: Edessä view of the FSP iFP600 UPS, showcasing its compact design and integrated LCD display.
2. Turvallisuusohjeet
Please adhere to these important safety guidelines during installation, operation, and maintenance of the UPS:
- Älä avaa UPS-koteloaasing. Laitteen sisällä ei ole käyttäjän huollettavia osia. Anna kaikki huoltotoimenpiteet pätevän huoltohenkilöstön tehtäväksi.
- Do not connect appliances that could overload the UPS, such as laser printers, vacuum cleaners, or heaters.
- Varmista, että UPS on kytketty maadoitettuun pistorasiaan.
- Avoid placing the UPS in direct sunlight, near heat sources, or in environments with excessive dust, humidity, or corrosive substances.
- Position the UPS in a well-ventilated area to prevent overheating.
- In case of fire, use a dry chemical extinguisher. Water can be hazardous.
- UPS-laitteen sisällä oleva akku ei ole käyttäjän vaihdettavissa. Akun vaihdon saa suorittaa vain pätevä henkilöstö.
3. Tuote ohiview
The FSP iFP600 UPS provides reliable power protection for your critical electronics. It features a compact design and an intuitive LCD display for monitoring status.
3.1 Pakkauksen sisältö
Kun avaat pakkauksen, tarkista, että kaikki osat ovat mukana ja ehjät:
- FSP iFP600 UPS Unit
- Käyttöopas (tämä asiakirja)
- Virtajohto
- USB-tiedonsiirtokaapeli

Image 3.1: The FSP iFP600 UPS shown alongside its retail packaging, illustrating the product's presentation.
3.2 Takapaneelin osat
Familiarize yourself with the connections on the rear panel of the UPS:

Kuva 3.2: Yksityiskohtainen view of the FSP iFP600 UPS rear panel, highlighting connection points.
- Pistorasiat: Two SCHUKO type outlets for connecting protected equipment.
- AC-tulo: Connects the UPS to the main utility power.
- Fuse/Breaker: Overcurrent protection for the UPS.
- USB-tiedonsiirto: Port for connecting to a computer for monitoring and management.
- Combo RJ11/RJ45 Surge Protection: Tarjoaa ylijännitesuojan puhelin-/verkkolinjoille.
4. Asennus ja asennus
Follow these steps to set up your FSP iFP600 UPS:
- Purkaminen: Poista UPS varovasti pakkauksestaan. Tarkista mahdolliset kuljetusvauriot.
- Sijoitus: Place the UPS on a flat, stable surface in a clean, cool, and well-ventilated area. Ensure adequate clearance around the unit for airflow.
- Alkulataus: Connect the UPS to a standard grounded AC outlet using the provided power cord. Allow the unit to charge for at least 4-6 hours before initial use to ensure optimal battery performance. The UPS will charge whether it is turned on or off.
- Liitäntälaitteet: Plug your computer, monitor, and other critical electronic devices into the UPS outlets (A). Do not connect surge suppressors or power strips to the UPS outlets.
- USB-tiedonsiirto (valinnainen): Connect the USB cable from the UPS USB port (D) to your computer's USB port to enable power management software features (software not included, typically downloaded from manufacturer's websivusto).
- RJ11/RJ45 Protection (Optional): For surge protection of your telephone or network line, connect the incoming line to the 'IN' port of the Combo RJ11/RJ45 (E) and connect the 'OUT' port to your device.
5. Käyttöohjeet
5.1 Virran kytkeminen päälle/pois
- Virran kytkeminen: Press and hold the power button on the front panel for approximately 2 seconds until you hear a beep and the LCD display illuminates.
- Virran sammuttaminen: Press and hold the power button for approximately 2 seconds until you hear a beep and the LCD display turns off.
5.2 LCD-näytön tiedot
The FSP iFP600 features an LCD display that provides real-time status information. The display is touch-sensitive for navigating information.

Image 5.1: The LCD display of the FSP iFP600 UPS, indicating voltage output and its touch-screen functionality.
The LCD display typically shows:
- Tulo Voltage
- Lähtö Voltage
- Akun lataustaso
- Kuormitustaso
- Operating Mode (e.g., AC mode, Battery mode)
- Warning/Fault Indicators
5.3 Käyttö akkutilassa
When the utility power fails or fluctuates outside acceptable limits, the UPS will automatically switch to battery mode. During battery mode, the UPS will provide power to connected equipment from its internal battery. An audible alarm will sound to indicate battery operation.
6. Huolto
Asianmukainen huolto varmistaa UPS-laitteesi pitkän käyttöiän ja luotettavuuden.
- Puhdistus: Puhdista UPS-laitteen ulkopinta pehmeällä, kuivalla liinalla. Älä käytä nestemäisiä tai aerosolipuhdistusaineita.
- Akun hoito: To maximize battery life, ensure the UPS is connected to AC power and fully charged. If the UPS is stored for an extended period, recharge it every three months to prevent battery degradation.
- Akun vaihto: The internal battery (12V / 7Ah x1) is not user-serviceable. Battery replacement should only be performed by FSP-certified service personnel or a qualified technician. Incorrect battery replacement can pose a risk of explosion or injury.
- Varastointi: Store the UPS in a cool, dry place with adequate ventilation. Ensure the battery is fully charged before storage.
7. Vianmääritys
Refer to the following table for common issues and their solutions. If the problem persists, contact FSP support.
| Oire | Äänihälytys | Mahdollinen syy | Ratkaisu |
|---|---|---|---|
| UPS operating on battery power | Piippaa 10 sekunnin välein | Utility power failure or fluctuation | Save work and shut down equipment if power outage is prolonged. UPS will return to AC mode when power is restored. |
| Alhaisen akun varoitus | Piippaus joka sekunti | Akun varaus on kriittisen alhainen | Immediately save work and shut down connected equipment. |
| Ylikuormitustila | Piippaus 0.5 sekunnin välein | Connected equipment exceeds UPS capacity | Disconnect non-essential equipment until the alarm stops. Ensure total load is within UPS capacity. |
| UPS vika | Jatkuva piippaus | Sisäinen vika tai toimintahäiriö | Turn off the UPS and disconnect it from the AC outlet. Contact FSP technical support. |

Image 7.1: Excerpt from the FSP iFP series specification table, detailing alarm indicators and their meanings.
8. Tekniset tiedot
Detailed technical specifications for the FSP iFP600 UPS:
| Ominaisuus | Erittely |
|---|---|
| Malli | iFP 600 |
| Kapasiteetti | 600 VA / 360 W |
| Tulo Voltage | 110/120 Vac or 220/230/240 Vac |
| Tulo Voltage Alue | 81-145 Vac / 140-290 Vac |
| Tulotaajuusalue | 60/50 Hz (automaattinen tunnistus) |
| Lähtö Voltage | 110/120 Vac or 220/230/240 Vac |
| AC Voitage Säätö (akkutila) | ±10 % |
| Output Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz |
| Siirtoaika | Tyypillinen 2-6 ms |
| Aaltomuoto (Batt. Tila) | Simuloitu sinewave |
| Akun tyyppi ja numero | 12V / 7Ah x1 |
| Tyypillinen latausaika | 4 tuntia jopa 90 % kapasiteetista |
| Indikaattorit | LCD Display (Touch panel with digital information) |
| Suojaus | Overload, Discharge, and Overcharge Protection |
| Tuotteen paino | 9.24 puntaa (4.2 kg) |
| Tuotteen mitat (PxLxK) | 11.81 x 3.98 x 5.59 tuumaa |
| Väri | Musta |
| Materiaali | Metalli |
9. Takuu ja tuki
FSP products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official FSP website. For technical support, troubleshooting assistance, or service inquiries, please contact FSP customer service through their official channels.
Lisätietoja ja tukiresursseja löydät osoitteesta FSP Store on Amazon.