QuietWarmth THERMST-D

QuietWarmth THERMST-D Non-Programmable Thermostat User Manual

For 120V or 240V Radiant Heat Systems

1. Johdanto

The QuietWarmth THERMST-D Non-Programmable Thermostat is designed to provide reliable control for 120V or 240V electric radiant floor heating systems. This thermostat offers flexible temperature management, allowing you to configure it for control based on floor temperature, room temperature, or a combination of room temperature with a floor temperature limit. It features a built-in Ground Fault Circuit Interrupter (GFCI) for enhanced safety and a clear, backlit display for easy monitoring and operation. A floor sensor is included to ensure accurate temperature readings and optimal comfort.

Edessä view of the QuietWarmth THERMST-D Non-Programmable Thermostat, showing the digital display and control buttons.

Kuva 1: Etuosa view of the THERMST-D Thermostat.

2. Turvallisuustiedot

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or property damage.

  • VAROITUS: To reduce the risk of electric shock, do not connect this device to a circuit with any phase operating down more than 150 volts to ground.
  • Asennuksen saa suorittaa vain pätevä sähköasentaja paikallisten ja kansallisten sähkömääräysten mukaisesti.
  • The thermostat requires connection to a dedicated 20 Amp piiri.
  • The resistive load connected to the thermostat must not exceed 15 Amps.
  • Electric radiant floor heating systems are required by the National Electrical Code to be protected by a Ground Fault Circuit Interrupter (GFCI). This thermostat has a built-in GFCI.
  • Always turn off power at the circuit breaker before installing or servicing the thermostat.
Sivu view of the QuietWarmth THERMST-D Thermostat showing a warning label regarding electric shock risk.

Kuva 2: Sivu view of the thermostat with safety warning label.

3. Pakkauksen sisältö

Varmista, että pakkauksessa on kaikki tarvittavat osat:

  • QuietWarmth THERMST-D Non-Programmable Thermostat
  • Lattia -anturi

4. Tuote ohiview

4.1 Tärkeimmät ominaisuudet

  • Non-Programmable operation for radiant floor heat systems.
  • Compatible with both 120V and 240V heating systems.
  • Integrated Ground Fault Circuit Interrupter (GFCI) for safety.
  • Clear, backlit LED display for easy reading.
  • Includes a floor sensor for precise temperature control.
  • Configurable for floor temperature, room temperature, or room temperature with a floor temperature limit.
  • Seven-day energy log to monitor power consumption.
  • Supports multiple QuietWarmth mats: up to 120 sq ft for 120V systems, or 240 sq ft for 240V systems.

4.2 Komponentit

The thermostat consists of a front display unit with control buttons and a back plate for electrical connections.

  • Etupaneeli: Features a digital display showing time and temperature, along with 'Up', 'OK', and 'Down' buttons for navigation and setting adjustments.
  • Takapaneeli: Contains wiring terminals for power input (L1, L2) and load output, as well as a connection point for the floor sensor.
Takaisin view of the QuietWarmth THERMST-D Thermostat showing wiring terminals labeled L1(L), L2(N), and Load, along with a mounting screw.

Kuva 3: Takaosa view termostaatin johdotusliittimet.

Image of the QuietWarmth floor sensor, a black cable with a small probe at the end.

Figure 4: Included floor sensor.

5. Asennus ja asennus

Asennuksen saa suorittaa vain pätevä sähköasentaja.

5.1 Asennus

  • The thermostat is designed for wall mounting.
  • Ensure the mounting location is free from direct sunlight, drafts, or other heat sources that could affect temperature readings.

5.2 Johdotus

Ennen johdotuksen aloittamista varmista, että virta on POIS katkaistu sulakkeesta.

  1. Connect the thermostat to a dedicated 20 Amp piiri.
  2. Identify the Line (power supply) and Load (heating mat) wires.
  3. Connect the Line wires to the L1(L) and L2(N) terminals on the thermostat's back panel.
  4. Connect the Load wires from the heating mat to the 'Load' terminals on the thermostat.
  5. Varmista asianmukainen maadoitus paikallisten sähkömääräysten mukaisesti.
  6. The thermostat is dual-voltage; it can be used with either 120V or 240V heating mats, but not simultaneously. Verify your heating mat's voltage vastaa virtalähdettä.

5.3 Floor Sensor Placement

The floor sensor is crucial for accurate floor temperature control.

  • Place the sensor next to the long edge of the QuietWarmth heating mat.
  • Ensure the sensor is positioned in the heated area and not near any unheated zones or external heat sources.
  • Route the sensor wire carefully to avoid damage during installation of flooring materials.
An illustration showing a golden retriever dog sleeping on a floor with radiant heat film installed underneath, indicating warmth for floating floors.

Kuva 5: Esimample of radiant heat film installation under floating floors.

An illustration showing a French bulldog puppy sleeping on a floor with radiant heat film installed underneath, indicating warmth for tile and glued floors.

Kuva 6: Esimample of radiant heat film installation under tile and glued floors.

6. Käyttöohjeet

6.1 Virta päälle

After installation, restore power at the circuit breaker. The thermostat display will illuminate.

6.2 Lämpötilan asetus

  • Käytä Up ja Alas painikkeita halutun lämpötilan säätämiseksi.
  • Paina OK -painiketta vahvistaaksesi valintasi.

6.3 ohjaustilat

The thermostat can be configured to operate in one of three control modes:

  • Floor Temperature Control: The thermostat maintains the floor at the set temperature using the floor sensor.
  • Huoneen lämpötilan säätö: The thermostat maintains the room air temperature at the set point.
  • Room Temperature Control with Floor Limit: The thermostat primarily controls room air temperature but prevents the floor temperature from exceeding a specified maximum limit, protecting sensitive flooring materials.

Refer to the full installation guide for instructions on how to select and configure these control modes.

6.4 Energy Log

The thermostat features a seven-day energy log, allowing you to monitor the power consumption of your radiant heating system. Consult the detailed manual for accessing and interpreting this data.

7. Huolto

7.1 Vikavirtasuojakytkimen testaus

For continued safety, the built-in GFCI should be tested monthly.

  1. Paina TESTATA button located on the bottom of the thermostat.
  2. The GFCI should trip, cutting power to the heating system and indicating a fault.
  3. Paina RESET button to restore power.
  4. If the GFCI does not trip or reset correctly, discontinue use and contact a qualified electrician.
Pohja view of the QuietWarmth THERMST-D Thermostat showing the GFCI test button and 'Test Monthly' text.

Figure 7: Bottom of the thermostat with GFCI test button.

7.2 Puhdistus

Pyyhi termostaatin ulkopinta pehmeällä,amp kangas. Älä käytä hankaavia puhdistusaineita tai liuottimia.

8. Vianmääritys

If you encounter issues with your QuietWarmth THERMST-D thermostat, refer to the following common problems and solutions:

  • Ei näyttöä/ei virtaa:
    • Check the circuit breaker for the dedicated circuit and ensure it is in the ON position.
    • Varmista, että kaikki johdotusliitännät ovat tukevasti ja oikein.
  • Lämmitysjärjestelmä ei käynnisty:
    • Ensure the thermostat is set to a temperature higher than the current room or floor temperature.
    • Check if the GFCI has tripped (press the RESET button if it has).
    • Confirm the correct control mode is selected (floor, room, or room with limit).
  • GFCI-matkoja usein:
    • This indicates a ground fault. Immediately turn off power at the circuit breaker.
    • Inspect the heating mat and wiring for any damage or moisture.
    • Ensure the total resistive load does not exceed 15 Amps.
    • Contact a qualified electrician for diagnosis and repair.
  • Epätarkat lämpötilalukemat:
    • Verify the floor sensor is correctly installed and not damaged.
    • Ensure the thermostat is not exposed to drafts, direct sunlight, or other external heat sources.

For issues not covered here, please contact QuietWarmth customer support or a qualified electrician.

9. Tekniset tiedot

ErittelyYksityiskohta
MerkkiHiljainenLämpö
Mallin nimiQuietWarmth Non-Programmable Thermostat
OsanumeroTHERMST-D
Tuotteen mitat3" S x 4" L x 6" K
Tuotteen paino11.4 unssia
VäriValkoinen
MateriaaliMuovi
Voitage120 volttia, 240 volttia
Max Resistive Load15 Amps
VirtalähdeKiinteä
Ohjaimen tyyppiPainike
Lämpötilan säätimen tyyppiManuaalinen
Näytön tyyppiLED (Backlit)
YhteystekniikkaLangallinen
ErikoisominaisuusEnergy Usage Tracking, Built-in GFCI
AsennustyyppiSeinäteline