1. Tuote ohiview
The Red Lion RLCB05-115 VMC Control Box is specifically designed for use with 1/2 HP, 115-Volt, 3-wire, single-phase submersible deep well pumps. This control box features a robust construction and is engineered to provide reliable operation for your well pump system.

Figure 1: Red Lion RLCB05-115 VMC Control Box.
Tärkeimmät ominaisuudet:
- Yhteensopivuus: Designed for 1/2 HP, 115 Volt, 3-wire, single-phase deep well submersible pumps.
- Kestävyys: Features heavy-duty, box-type terminals and a weather-resistant seal.
- Turvallisuusarvioinnit: UL listed for use in the USA and Canada, with a NEMA Enclosure 3 rating for indoor/outdoor use.
- Suojaus: Includes quick disconnect relay, overloads, and capacitors for thermal protection.
- Rakenne: Assembled in the USA, ensuring quality and reliability.
2. Turvallisuustiedot
Read all instructions carefully before installation and operation. Failure to follow these instructions may result in serious injury, death, or property damage.
- Sähköinen vaara: Always disconnect power before servicing or installing the control box. Only qualified personnel should perform electrical work.
- Oikea maadoitus: Ensure the control box is properly grounded according to local electrical codes.
- Sovellus: This control box is for 3-wire submersible pumps only. 2-wire pumps do not require a control box. Verify your pump type before installation.
- Ympäristöolosuhteet: The NEMA Enclosure 3 rating allows for indoor/outdoor use, but protect from direct water spray or submersion.
3. Asennus ja asetukset
The control box should be mounted in a secure location, protected from physical damage. It includes four 7/8-inch knockouts, three 1-1/8-inch knockouts, a drain hole, and two mounting holes for flexible installation.

Figure 2: Internal components and knockouts of the control box.
Asennus:
- Choose a suitable location for mounting, ensuring it is easily accessible for maintenance and protected from environmental extremes.
- Use the two mounting holes on the back of the control box to secure it to a flat, stable surface.
- Varmista riittävä ilmanvaihto laitteen ympärillä.
Järjestelmä ohiview:

Figure 3: Typical submersible well pump system installation diagram.
4. Wiring and Electrical Connections
Refer to the wiring diagram below for correct electrical connections. All wiring must comply with national and local electrical codes.

Figure 4: Wiring diagram for the VMC Submersible Motor Control box.
Liitäntävaiheet:
- Virtalähde: Connect the incoming power supply to terminals L1 and L2.
- Motor Leads: Connect the motor leads from the submersible pump to terminals R (Start), Y (Motor Leads), and B (Main) as indicated on the diagram.
- Maadoitus: Connect the ground wire from the power supply and the pump to the GRND terminal.
- Kondensaattori: The control box includes a capacitor start/run design with thermal protection. Ensure all internal connections are secure.
5. Käyttö
Once properly installed and wired, the control box provides responsive control for your submersible well pump. The clearly labeled switches and indicators facilitate straightforward operation.
- Virta päälle/pois: Use the main switch on the control box to power the pump on or off.
- Merkkivalot: Observe any indicator lights for operational status or fault conditions.
- Automaattinen lämpösuojaus: The system includes automatic thermal protection in the motor to prevent overheating.
6. Huolto
The Red Lion RLCB05-115 control box is designed for minimal maintenance. Regular checks can help ensure long-term reliability.
- Säännöllinen puhdistus: Occasionally dust the exterior of the control box to prevent accumulation of dirt and debris.
- Yhteyden tarkistukset: Tarkista säännöllisesti kaikki sähköliitännät varmistaaksesi, että ne ovat tiukasti kiinni ja että niissä ei ole korroosiota.
- Ympäristötarkastus: Check the control box for any signs of water ingress or physical damage. Ensure the weather-resistant seal is intact.
7. Vianmääritys
If you experience issues with your well pump system, consider the following general troubleshooting steps:
- Ei virtaa: Check the main power supply, circuit breakers, and all electrical connections to the control box.
- Pumppu ei käynnisty: Verify that the control box switch is in the 'ON' position. Check for any tripped overloads or thermal protection activation.
- Epätavalliset äänet: Disconnect power and inspect the pump and control box for any loose components or wiring.
For complex issues or if you are unsure about any troubleshooting steps, it is recommended to consult a qualified electrician or pump technician. Do not attempt repairs beyond your technical capability.
8. Tekniset tiedot

Figure 5: Dimensions of the RLCB Series Control Boxes.
| Erittely | Yksityiskohta |
|---|---|
| Mallinumero | RLCB05-115 (640188) |
| Hevosvoimat (HP) | 1 / 2 HP: |
| Voitage | 115 volttia |
| Vaihe | Yksivaiheinen |
| Materiaali | Ruostumaton teräs (kotelo) |
| Väri | Harmaa |
| Tuotteen mitat (S x L x K) | 72 mm x 122 mm x 214 mm (2.84" x 4.81" x 8.41") |
| Tuotteen paino | 2.5 puntaa (1.13 kg) |
| Kotelon luokitus | NEMA Enclosure 3 (Indoor/Outdoor) |
| Sertifikaatit | UL Listed (USA and Canada) |
| Mukana olevat komponentit | Ohjauslaatikko |
| UPC-/GTIN-koodi | 010121122031 |

Figure 6: Product label with model details and contact information.
9. Takuutiedot
This Red Lion RLCB05-115 VMC Control Box is covered by a 2 vuoden valmistajan takuu ostopäivästä lukien. Säilytä ostokuitti takuuvaatimuksia varten.
For items purchased within 30 days, please refer to Amazon's 30-day return policy. After 30 days, if Amazon.com is the seller, your product is covered by the terms outlined in this manual. If another company is the seller, please contact them directly for warranty information.
10. Tuki ja yhteydenotto
Our team is available to assist with product selection, installation, maintenance, and troubleshooting.
- Technical Service Line: 888.885.9254
- Websivusto: redlionproducts.com
Please refer to your owner's manual for more detailed information or contact our staff for assistance.