Eaton OS310U-W-K

Eaton OS310U-W-K Motion Sensor Switch User Manual

Model: OS310U-W-K

1. Johdanto

The Eaton OS310U-W-K is a motion-activated occupancy sensor wall switch designed to automatically control lighting based on room occupancy. This device enhances energy efficiency by turning lights on when a person enters a room and off after a selectable time delay once the room is vacated. It is compatible with a wide range of lighting loads, including incandescent, magnetic low voltage (MLV), electronic low voltage (ELV), fluorescent, compact fluorescent (CFL), and LED lights, as well as motors up to 1/6 HP.

This manual provides detailed instructions for the safe installation, operation, and maintenance of your Eaton OS310U-W-K motion sensor switch.

2. Turvallisuustiedot

VAROITUS: To avoid fire, shock, or death; turn off power at the circuit breaker or fuse box and test that the power is off before wiring. All wiring must be performed in accordance with national and local electrical codes.

  • Katkaise aina virta sulakkeesta ennen asennusta tai huoltoa.
  • A neutral wire is required for the installation of this device. Verify your switch box wiring includes a neutral wire before proceeding.
  • Tämä laite on tarkoitettu vain sisäkäyttöön.
  • Do not use with dimmable fluorescent fixtures unless specifically rated for occupancy sensor control.
  • Jos olet epävarma jostakin asennusprosessin osasta, ota yhteyttä pätevään sähköasentajaan.

3. Tuotteen ominaisuudet

  • Automaattinen toiminta: Lights turn on automatically upon motion detection and off after a set delay.
  • Monipuolinen yhteensopivuus: Works with incandescent, MLV, ELV, fluorescent, CFL, and LED lighting loads, as well as 1/6 HP motors.
  • Laaja kattavuus: Tarjoaa 180 asteen kentän view and up to 1000 square feet of major motion coverage.
  • Joustava johdotus: Supports both single-pole and 3-way wiring configurations.
  • Säädettävä aikaviive: Selectable time delays of 5 seconds (test mode), 5 minutes (factory default), 15 minutes, and 30 minutes.
  • Ambient Light Override: Prevents lights from turning on if sufficient natural light is present.
  • Integrated Nightlight: Selectable on/off LED nightlight with press-and-hold dimming function.
  • Walk-in-Delay Feature: Shortens the time delay when motion is detected briefly, saving energy.
  • Toimintatilat: Toggle between auto-on/auto-off or manual-on/auto-off modes.
  • Ohitustoiminto: Allows the sensor to operate as a traditional manual on/off switch.
  • LED-ilmaisin: Green LED indicates load status, acts as a locator light in the dark, and blinks upon motion detection.
  • Decorator Style: Includes a mid-size decorator wall plate.

4. Asennus ja asennus

The Eaton OS310U-W-K is designed to fit into a standard wall box and replaces a traditional light or fan switch. Installation requires a neutral wire. If your existing switch box does not have a neutral wire, consult an electrician.

4.1 Johdotusvaatimukset

  • Tarvittavat johdot: Ground, Hot (Line), Load, and Neutral.
  • 3-tieinen kokoonpano: For 3-way operation, an additional traveler wire is needed. Note that 3-way wiring for this sensor switch differs from standard 3-way switches; the wiring is effectively in parallel. Refer to the detailed wiring diagram provided with your product packaging for specific instructions.
  • The device comes with 6-inch pre-stripped #14 AWG wire leads for connection.

4.2 Asennusvaiheet

  1. Sammuta virta: At the circuit breaker or fuse box, turn off the power to the switch location. Verify power is off using a voltage testaaja.
  2. Vanhan kytkimen poistaminen: Carefully remove the existing wall plate and switch from the wall box. Disconnect the wires from the old switch, noting their connections.
  3. Tunnista johdot: Identify the Line (Hot), Load, Neutral, and Ground wires in the wall box. The neutral wire is typically white.
  4. Yhdistä uusi kytkin: Connect the wires from the Eaton OS310U-W-K switch to the corresponding wires in the wall box using wire nuts. Ensure all connections are secure.
    • Connect the green wire from the sensor to the bare copper or green ground wire in the wall box.
    • Connect the black wire from the sensor to the Line (Hot) wire.
    • Connect the red wire from the sensor to the Load wire (to the light fixture).
    • Connect the white wire from the sensor to the Neutral wire.
    • For 3-way installations, refer to the specific wiring diagram provided with the product.
  5. Asennuskytkin: Carefully fold the wires into the wall box and secure the switch to the wall box with the provided screws.
  6. Asenna seinälevy: Attach the decorator mid-size wall plate.
  7. Palauta virta: Kytke virta takaisin katkaisijasta.
Eaton OS310U-W-K Motion Sensor Switch, White

Image of the Eaton OS310U-W-K motion sensor switch in white, showing its decorator style and push-button interface.

5. Käyttöohjeet

5.1 Automatic Operation (Occupancy Mode)

In this mode, the lights will automatically turn on when motion is detected and turn off after the set time delay once the room is vacant. This is the default operating mode.

5.2 Manual-On / Auto-Off Mode (Vacancy Mode)

To switch to manual-on/auto-off mode, press and hold the main switch button for a few seconds until the indicator light changes. In this mode, you must manually turn on the lights by pressing the switch button. The lights will then automatically turn off after the set time delay when no motion is detected.

5.3 Bypass Feature (Traditional Switch Mode)

The bypass feature allows the sensor to function as a traditional manual on/manual off switch, ignoring motion detection. Consult the product's detailed instructions for how to activate and deactivate this mode, typically involving a specific press-and-hold sequence.

5.4 Yövalotoiminto

The integrated LED nightlight can be turned on or off and its brightness adjusted. Press and hold the nightlight button (if separate) or a specific section of the main button to dim the nightlight. The nightlight provides a locator light in the dark.

5.5 LED-merkkivalo

A green LED on the switch indicates the load status (lights on/off). It also serves as a locator light in dark conditions and blinks to signal motion detection.

6. Konfigurointiasetukset

The Eaton OS310U-W-K offers several adjustable settings to customize its operation. These settings are typically accessed by removing the wall plate and adjusting small dials or switches on the device itself.

6.1 Time Delay Adjustment

The time delay determines how long the lights remain on after the last detected motion. Available settings include:

  • 5 seconds (Test Mode)
  • 5 minutes (Factory Default)
  • 15 minuuttia
  • 30 minuuttia

6.2 Ambient Light Override

This setting allows you to prevent the lights from turning on automatically if there is sufficient natural light in the room. This feature helps conserve energy by ensuring lights are only activated when truly needed.

6.3 Walk-in-Delay

The walk-in-delay feature intelligently shortens the time delay if motion is detected only briefly, further optimizing energy savings.

7. Huolto

The Eaton OS310U-W-K motion sensor switch requires minimal maintenance.

  • Puhdistus: To clean the device, gently wipe the surface with a soft, damp liinalla. Älä käytä hankaavia puhdistusaineita, liuottimia tai voimakkaita kemikaaleja, sillä ne voivat vahingoittaa pintakäsittelyä tai sisäisiä komponentteja.
  • Tarkastus: Periodically inspect the switch and wall plate for any signs of damage or loose connections. If any issues are found, turn off power at the circuit breaker and address them or consult a qualified electrician.

8. Vianmääritys

If you encounter issues with your Eaton OS310U-W-K motion sensor switch, refer to the following common problems and solutions:

Ongelma Mahdollinen syy Ratkaisu
Valot eivät syty liikkeestä.
  • Virta on pois päältä.
  • Virheellinen johdotus.
  • Ambient light override is active and room is too bright.
  • Sensor lens is obstructed.
  • Switch is in manual-on mode.
  • Tarkista katkaisija.
  • Tarkista johtojen liitännät (linja, kuorma, nolla, maadoitus).
  • Adjust ambient light setting or test in darker conditions.
  • Poista mahdolliset esteet anturin linssin edestä.
  • Switch to auto-on/auto-off mode.
Valot eivät sammu.
  • Jatkuvaa liikettä havaittu.
  • Aikaviive on asetettu liian pitkäksi.
  • Faulty wiring or device.
  • Ensure no constant motion sources are within sensor range.
  • Adjust time delay to a shorter setting.
  • Recheck wiring. If problem persists, contact support.
Switch is difficult to fit into wall box.
  • Bulky wiring or small wall box.
  • Carefully arrange wires to maximize space. Ensure all connections are secure and compact.
Nightlight not working or dimming.
  • Nightlight feature is off.
  • Virheellinen toiminta.
  • Activate the nightlight feature.
  • Use the press-and-hold function to adjust brightness.

9. Tekniset tiedot

Ominaisuus Erittely
Mallinumero OS310U-W-K
Käyttö Voltage 120 Vac, 60 Hz
Suurin wattitage 1000 W
Nykyinen luokitus 8.3 A
Yhteensopivat kuormat Incandescent, Magnetic Low-Voltage, Electronic Low-Voltage, Fluorescent, Compact Fluorescent (CFL), LED, Motors up to 1/6 HP
Kenttä View 180 astetta
Peittoalue Up to 1000 sq ft (major motion)
Aikaviiveasetukset 5 seconds (test), 5 minutes, 15 minutes, 30 minutes
Käyttölämpötila 32°F - 104°F (0°C - 40°C)
Materiaali Polycarbonate (housing), Copper (contact)
Mitat (P x L x K) 34 x 26.4 x 29.6 cm (approximate, as per item dimensions)
Sertifikaatit cULus listed, Nom certified, California Title 24 Compliant
Johdotus Single-pole or 3-way, Neutral required, 6-inch pre-stripped #14 AWG wire leads

10. Takuu ja tuki

10.1 Valmistajan takuu

Eaton products are backed by a manufacturer's warranty. Please refer to the warranty information included with your product packaging or visit the official Eaton websivustolta lisätietoja takuuehdoista, -olosuhteista ja -ajasta.

10.2 Tekninen tuki

For technical assistance, troubleshooting beyond this manual, or to inquire about replacement parts, please contact Eaton customer support. Contact information can typically be found on the product packaging, the Eaton website, or by searching for 'Eaton Electrical Support'.

When contacting support, please have your product model number (OS310U-W-K) and purchase date available.

© 2023 Eaton Corporation. Kaikki oikeudet pidätetään.

Tämä käyttöohje on tarkoitettu vain tiedoksi ja sitä voidaan muuttaa ilman erillistä ilmoitusta.